 Mist Collectors clear air of oils and coolants.Donaldson Australasia Pty Ltd
Wyong Australia
Feb 13, 2009
Dryflo collects mist generated by coolants and machining oils that pollute atmosphere and condense on surfaces. Combined with special outer wrap, and allowing gravity to aid drainage by sitting vertically inside collector, Dryflo prevens collected liquid from re-entering clean air stream. Differential pressure gauge indicates pressure drop correlating with filter exhaustion, while filter retention system enables rapid filter change and minimal human contact with collected oil.
|
Filtration Unit withstands system pressure up to 6,000 psi.Schroeder Industries LLC
Leetsdale, PA 15056-1025
Feb 11, 2009
Featuring sensor and EasyTest(TM) fittings, ET-100 can be used to troubleshoot in instances of poor systems performance or excessive machine downtime, to check performance on production line, and to check systems before and after rebuild. It can be used with large meters that are clearly marked with scales. Pressure bearing parts are thick-section aluminum extrusions, and load control knob and scale selector switches are designed to provide grasp under any conditions.
|
Filter provides high-pressure reverse-flow filtration.Schroeder Industries LLC
Leetsdale, PA 15056-1025
Feb 11, 2009
Designed for hydraulic filtration, BHF 60 offers inlet/outlet port options including SAE 4-bolt flange code 62 and SAE ports that allow installation without adapters. O-ring seals are available in Buna N, Viton, and EPR for compatibility with petroleum oils, synthetic fluids, water-glycols, oil/water emulsions, and high water base fluids. Other features include magnetic actuation, screw-in bowl mounted below filter head, and optional poppet-type bypass valve.
|
Gas Turbine Inlet Filters survive harsh environments.GE Energy Services
Liverpool, NY 13088
Jan 20, 2009
Suited for self-cleaning applications, Nanomedia LP9 pulse filter cartridge utilizes Nanomedia technology to deliver sub-micron particulate removal, with initial efficiency greater than 80% at 0.3 microns, and is rated MERV 15. Minipleat filters F8MX and F9MX, rated MERV 15 and 16 respectively per ASHRAE 52.2, are designed for low pressure loss and provide dust-holding capacity that prolongs filter life. They suit operating environments across power generation and oil/gas industries.
|
 Disposable Adsorption Filters remove vapors from gases.Parker Hannifin Corp.
Cleveland, OH 44124-4141
Jan 02, 2009
Constructed of nylon and supplied standard with ½ in. tube connections, Balston® In-line Disposable Adsorption Filters are capable of handling operating pressures up to 50 psig in gas service and up to 70 psig in liquid service. Examples of removable vapors include hydrocarbons, ketones, CO2, ammonia, mercury, methane, ethylene, methanol, and water vapor. Areas of use include sample analyzing, venting applications, emissions monitoring, and direct food contact applications.
|
 Filters have pre-formed conical shape.Xenosep Technologies LLC
Boonton, NJ 07005
Dec 05, 2008
Suited for organic extract drying applications and designed to fit in funnel perfectly every time, FunnelFit(TM) Pre-Formed Conical Filters eliminate need for solvents used to wet down and keep quadrant folded or pre-pleated filters in funnel. Available in 3 quantitative ashless grades, flters are packaged in stacks of 100.
|
Filter Element can be used as charge/return line filter.Schroeder Industries LLC
Leetsdale, PA 15056-1025
Nov 26, 2008
With max flow rating of 35 gpm and max operating pressure of 580 psi, GH Hydraspin Filters protect fluids in feed circuit of hydrostatic drives and continuously variable transmission (CVT) applications. Visual and electrical indicator options, along with full range of cartridge style element options, are available. Cartridge style element with integrated bypass valve comes in various media grades that can be application-specific.
|
 In-Line Filters are easily connected and disconnected.Industrial Specialties Mfg, Inc.
Englewood, CO 80110
Oct 15, 2008
Featuring end connections in OD sizes of ¼, 5/16 and 3/8 in., push-to-connect in-line filters are available in sizes ranging from 20-250 micron. They are designed with John Guest® push-to-connect style fittings integrated into Celcon® plastic filter housing. Units can be customized to meet requirements for air, vacuum, and some fluid applications.
|
Filter Cartridge reduces hydrocarbon contamination up to 95%.Pentair Industrial
Sheboygan, WI 53082
Oct 07, 2008
Constructed from modified cellulose-based filter media, Carbflex(TM) OAC-20BB oil absorbing filter cartridge allows filter media to chemically bond with hydrocarbons instantaneously, absorbing up to 95% of total hydrocarbons in single pass. Unit removes dissolved and dispersed oils for applications including auto service stations, car and truck washes, oil and gas facilities, machine and repair shops, shipping bilge water and surface water runoff at truck stops.
|
Liquid Filtration System has vertical rack design.Pentair Industrial
Sheboygan, WI 53082
Sep 15, 2008
Along with quick-change design for cartridge replacement, Aqualine® features 8 in. dia fiberglass housing available in 60 in. length with pleated cartridge construction and outside-in flow pattern that optimizes flow rates and minimizes pressure drop. Vertical rack design allows housings to be stacked, increasing flow while saving plant floor space. Areas of use include high-flow-rate applications, including food and beverage, chemical, cosmetics, and electronics.
|
Snap-In Pleated Bag features integral venturi.Menardi
Trenton, SC 29847
Sep 09, 2008
Utilizing moisture-resistant, spunbond polyester media for 99.9% efficiency, Mikro-Pleat V-Series incorporates full diameter venturi that is pressed into filter element's flexible head and bonded in place. Shape of venturi helps capture pulses from blow pipe nozzles that are worn or not perfectly aligned. During normal filter operation, venturi smoothes air flow, which minimizes pressure drop arcross orifice.
|
Purification System clears process gases of metal/moisture.Matheson Tri-Gas
Montgomeryville, PA 18936
Aug 19, 2008
Combining chemisorption and physisorption, PICO-TRAP Ultra-Purification System removes volatile metal impurities and moisture from critical process gases used by semiconductor manufacturers. It features cryogenic, fully-regenerable purification column and can remove moisture down to less than 20 ppb in hydrogen chloride. Applied to a variety of gases, system also removes volatile metals including iron, molybdenum, chromium, titanium, nickel, and manganese.
|
 Base-Ported Hydraulic Filter has up to 500 gpm flow capacity.Schroeder Industries LLC
Leetsdale, PA 15056-1025
Aug 06, 2008
Suited for mining, steel mills, and pulp and paper applications, Model QLF15 is equipped with fast acting stainless steel bypass valve. Offered in re-cleanable metal mesh, plastic coreless, or deep-pleated media for high dirt holding capacity, it has maximum operating pressure of 1,500 psi and temperature range of -20 to 225°F. Available in 16 and 39 in.sizes, hydraulic filter features L-ported design, porting base and cap of ductile iron, and element case of steel.
|
 Screening System macerates solids/debris in single operation.Mono Nov Group
Manchester M34 5JA United Kingdom
Jun 18, 2008
With capacity of up to 16,000 m³/hr, Discam can capture up to 95% of solids at 5 or 9 mm aperture sizes. It combines self-cleaning Discreen® with high torque Muncher, requiring no manual attendance/cleaning, and features high-flow side rail which increases fluid velocity through Muncher. Available in range of channel depths with 1,000, 1,500, and 2,000 mm options as standard, unit can be retrofitted into existing sewage pump stations or inlet works, as well as installed in new build facilities.
|
 Air Filters help optimize HVAC energy efficiency.Camfil Farr
Riverdale, NJ 07457
Jun 13, 2008
Suited for commercial or institutional environment with large air handling units, Durafil ES filters act as drop-in replacement for any standard V-shaped filter but feature radial inlet and outlet with optimized open area. Use of fine fiber Energy Star media ensures consistent performance throughout service life, and height-to-pleat spacing configuration maximizes active filter area. Also, built-in prefilter spacer section eliminates airflow blockage and resultant high pressure drop.
|
Horizontal Disc Filter System has 30,000 gph max flow rate.Mefiag Div., Met-Pro Corp.
Owosso, MI 48867
May 29, 2008
Along with corrosion-resistant construction and heavy-duty, 1,750 rpm FRP pumps, JUMBO Series utilizes 33 in., low-profile horizontal discs for optimal filtration capacity and minimal media changeouts. Single-chamber flow rates are available to 30,000 gph, and systems are suited for platers requiring high volume and high flow rates due to larger tank sizes and number of turnovers per hour.
|
Cavity Filters target WiMAX applications.MtronPTI
Orlando, FL 32804
May 19, 2008
With passband center frequencies from 2.3-2.7 GHz and available bandwidth range of 0.04-0.2% 1-dB, WiMAX Cavity Filters are suited for mobile and fixed WiMAX, WiBro, and Wi-Fi applications. Versatile configuration allows multiple cross-coupling schemes with transmission zeroes placed on either side of passband and in any combination. Filters feature extended rejection performance, achieved with integrated lowpass filter, and can also be used in either Rx and/or Tx mode.
|
Direct Air Cooling Filters feature ePTFE membrane media.Gore, W. L., & Associates, Inc., Sealant Technologies Group
Elkton, MD 22222
Apr 29, 2008
GORE® Cooling Filters include microporous membrane that allows cool, clean air to flow into cabinet while filtering out harmful contaminants such as dirt, dust, and sand. Expanded PTFE membrane has 99.0% particle filtration efficiency at 0.3 µm level. Available in either lightweight or anodized aluminium frame, filters are suited for wireless base stations, MCPAs, base band units, power cabinets, switching systems, and other outdoor electronic enclosures.
|
 Magnetic Filter features stainless steel construction.Eriez Magnetics
Erie, PA 16514
Apr 16, 2008
Capable of handling food and pharmaceutical powders, Dry Vibrating Magnetic Filter (DVMF) can remove fine abraded 316 stainless steel. It features high intensity, high gradient magnetic field generated in bore of solenoid coil encased in steel housing. Filter elements are provided by matrix system, consisting of series of stainless steel metal discs, that amplifies externally applied magnetic field and provides collection sites for capture of ferrous contaminants.
|
 Filter Media can be used in indoor and outdoor environments.Universal Air Filter Co.
Sauget, IL 62206
Apr 04, 2008
Formulated for high heat and humidity conditions in uncontrolled environments, Black Quadrafoam II media can withstand harsh environments. Filter frames can include special metal finishes for corrosion protection when exposed to moisture and harmful elements typically found in outdoor atmosphere. RoHS compliant media also meets standards and classifications such as UL 94 HF-1, UL 900 Class 2, CE, Telcordia NEBS GR-78-CORE, GR-63-CORE, GR-487-CORE, and FMVSS 302.
|