Tubular Filter Modules purify solids-laden waste water.Koch Membrane Systems, Inc.
Wilmington, MA 01887
Mar 16, 2006
Designed for ultrafiltration of industrial process streams and wastewater, INDUCOR(TM) and INDUCOR-G modules utilize KMS PVDF ultrafiltration membrane suited for treatment of oily wastes and metal hydroxide wastes. INDUCTOR modules are configured with ˝ in. dia tubules, while INDUCOR-G modules have 1 in. dia tubules. Applicable for systems with flow rates of 100,000 gpd and higher, open channel configurations are tolerant of high-solids streams.
|
 Rigid Cell Filters offer extended surface chemical filtration.D-Mark, Inc.
Chesterfield, MI 48051 2600
Mar 15, 2006
Self-supporting OdorGuard® Rigid Cell Filters remove odors, VOCs, and light gases. Units are available with granular activated carbon or 50/50 blend of carbon and activated alumina impregnated with 5% potassium permanganate. Filters are 24 x 24 x 12 in., pleated, and provide 7 lb of GAC or 8.6 lb of 50/50 adsorbent blend. Galvanized steel frames resist corrosion in moist, humid conditions, and are available with or without header.
|
 Filtration System features permanent-media design.Hennig, Inc.
Machesney Park, IL 61115
Feb 08, 2006
Self-cleaning Cast-Iron CDF Filtration System eliminates cast-iron chips and fines as small as 25 microns from recirculating coolant without need for disposable filter media.
System is available with capacities ranging from 10-300 gpm in wide range of sizes to meet needs of single-machines or cells in cast-iron machining operations.
|
 Syringe Filters offer retention ratings of 0.2 and 0.4 µm.Meissner Filtration Products, Inc.
Camarillo, CA 93012 8760
Feb 06, 2006
Offered in sterile and non-sterile versions, Disposable 25 mm Syringe Filters are designed for scaleup evaluation of membrane filters to capsules, cartridge filters, and UltraCap® high-capacity disposable filter assemblies. Choice of filter membranes for evaluation includes SteriLUX® PVDF and STyLUX® PES. Syringe filters are non-cytotoxic and nonpyrogenic. All materials are biosafe in compliance with USP Class VI Plastics biological reactivity tests.
|
 Pleated Panel Filters won't delaminate, buckle, or collapse.Airguard Industries, Inc.
Louisville, KY 40218
Jan 19, 2006
Able to snap back to original shape if damaged or deformed with no loss of structural integrity, X-Treme(TM) filters employ self-supported media that offers moisture resistance and eliminates need for expanded metal backing. Inherent media strength and stiffness result in consistent pleat shape, spacing, and height. Fully incinerable products, rated MERV 7, do not support microbial growth or contain any metal components.
|
 PES Membrane Filter handles biological fluids.Meissner Filtration Products, Inc.
Camarillo, CA 93012 8760
Jan 17, 2006
Able to filter fluids such as blood products, serum, cell and tissue culture media, EverLUX(TM) polyethersulfone (PES) membrane filter is designed for maximum contaminant capacity. Asymmetric structure withstands high particle loads and protein concentrations. Offered with absolute retention ratings of 0.2, 0.4, and 0.6 µm, permanently hydrophilic filter is optimized for sterile filtration, prefiltration, and clarification applications.
|
Spiral Elements provide desalting and protein separation.Koch Membrane Systems, Inc.
Wilmington, MA 01887
Dec 15, 2005
Suited for dairy applications, TFC®-SR®3 nanofiltration elements utilize polyamide thin-film composite membranes. Spiral wound membranes pass monovalent salts such as sodium chloride, yet retain divalent salts, proteins, and sugars. Retention of sugars, such as lactose, typically exceeds 99%. Available in 4 and 8 in. dia at 38 and 39 in. lengths, spiral elements can be used for whey pre-concentration, salt whey diafiltration, and lactose demineralization.
|
 Ceramic Foam Filters remove impurities from liquid metal.Blasch Precision Ceramics, Inc.
Albany, NY 12204
Dec 09, 2005
Offered in sizes from 10-600 mm and thicknesses from 10-50 mm, Cleen-Flo Filters are available in alumina for use with aluminum and aluminum alloys, zirconia for stainless steel and nickel alloys, and silicon carbide for grey iron, ductile iron, precious metals, copper, bronze, and brass. All come in square, round, and custom shapes with pore densities from 8-60 pores/in. Thermal and chemical stability avoids any reaction with molten metal being filtered.
|
 Filter Element targets water treatment operations.Koch Membrane Systems, Inc.
Wilmington, MA 01887
Nov 29, 2005
Measuring 18 in. in diameter x 61 in. long, MegaMagnum spiral reverse osmosis (RO) and nanofiltration (NF) element contains over 2,800 ft˛ of membrane surface area. Product helps reduce installed cost of large- and medium-scale RO systems designed for brackish water treatment or municipal water reuse as well as nanofiltration systems where softening or organics removal is desirable treatment for drinking water supplies.
|
 Reverse Osmosis Membrane Elements help increase efficiency.Koch Membrane Systems, Inc.
Wilmington, MA 01887
Nov 29, 2005
FLUID SYSTEMS® Reverse Osmosis membrane elements provide high rejection at low pressure and feature thin film composite TFC® membranes that can last from 4-8 years on average or up to 12 years max. Membrane elements are suited for commercial and industrial brackish water treatment and seawater desalination applications.
|
Pleated Filters absorb odors, light gases, and VOCs.D-Mark, Inc.
Chesterfield, MI 48051 2600
Nov 18, 2005
Approved to UL class 2, OdorGuard Plus 1, 2, and 4 in. Pleated Filters offer adsorbent loadings of 125, 250, and 375 g/ft˛ of filter area. Pleats offer equal volumes of 60% activity activated carbon and activated alumina impregnated with 5% potassium permanganate. Blend of adsorbents removes odors, VOCs, and light gases, including ammonia, formaldehyde, hydrogen sulfide, and sulfur dioxide. Filters do not use adhesives and will not shed or dust in application.
|
 Gas Filters target GC and GC/MS analyses.Thermo Electron Corp.
Waltham, MA 02454
Nov 09, 2005
Click-On and Super Clean filter gas going into GC and GC/MS systems to 99.9999% pure or 6.0 grade, optimizing analyses, compound identification, and quantitation. Inline Click-On is equipped with reusable end fittings, which contain needle valves that seal gas line during filter replacement, preventing contamination. Super Clean cartridge gas filter utilizes base plates to hold cartridge and is available in various designs depending on gas combination to be filtered.
|
 Filtration Module suits surface finishing applications.Orelis S.A.S
Miribel 01708 France
Oct 05, 2005
Intended for ultrafiltration of electrophoretic paint, Pleiade® MP4 consists of stack of separate membranes. Users can see quality of permeate from each membrane though window and isolate individual membranes by means of small valve, eliminating production stoppage. Offering alternative to spiral systems and manufactured from plastics and composites, filter is modular, interchangeable, and resistant to corrosion.
|
Camera Filter protects lens without degrading image quality.Tiffen Co. LLC, The
Hauppauge, NY 11788
Sep 13, 2005
Designed from ultra quality optical glass, Digital Ultra Clear filter protects lens against dirt, grime, fingerprints, and unexpected bumps and bruises. It is available in sizes up to 82 mm to fit motion picture, broadcast, still photographic, and digital cameras. Product may be kept on camera lens at all times without compromising image quality.
|
 Inertial Bypass Filters extend CEMS analyzer life.Perma Pure Inc.
Toms River, NJ 08754
Sep 01, 2005 In high particulate, dusty environments such as cement mills or coal-fired power plants, FB-Series removes large particles of dust and ash from gas samples, preventing clogging of finer porosity filters of analysis equipment. Stainless steel construction tolerates corrosive gas environments, and high velocity flow enables self-cleaning for maintenance-free operation. Range of flow ratings and filter elements are available to suit monitoring application. |
 Submerged Membrane Modules provide wastewater treatment.Koch Membrane Systems, Inc.
Wilmington, MA 01887
Jul 29, 2005 PURON® Modules are intended for membrane bioreactor treatment of municipal and industrial wastewater. Hollow fiber membranes, 2 mm in diameter, with pore size of less than 0.1 µm, are bundled in single header at lower end. Each hollow fiber membrane filter is sealed at upper end and allowed to float freely. With water flowing from outside to inside of filters, solids and particulates are blocked by membrane and remain on outside, while permeate is withdrawn from inside of fibers. |
Membrane Disk minimizes chemical waste.Mykrolis Corp.
Billerica, MA 01821
Jul 20, 2005 Optimizer® C47 enables R and D evaluation of membrane technology for photoresist and chemical filtration on laboratory scale using small volumes of chemicals. Accommodating variety of membranes, including hydrophobic and hydrophilic special clean membranes for applications requiring lower organic content, C47 enables rapid filtration testing and speeds time to production. |
 Water Purifier features carbon and air filters.SpectraPure, Inc.
Tempe, AZ 85281-2941
Jul 19, 2005 With 40 gal tank and variable pressure delivery pump, SP-1000C delivers 1,000 gal/day of pH balanced drinking water. Self-cleaning backwash carbon filter holds 40 lb of carbon and removes chlorine, sediment, bad tastes, and odor. Air vent filter and safety overflow prevent airborne contamination, and single RO membrane can be replaced without removing housing. Unit requires 26 x 22 in. of space, 4 water connections, and 110 Vac for installation. |
 Process Medium removes/reduces iron and hydrogen sulfide.KDF Fluid Treatment, Inc.
Three Rivers, MI 49093 9287
Jul 14, 2005 Providing point-of-entry treatment of groundwater supplies, KDF® 85 copper-zinc alloy formulation can be used alone or to protect existing water filtration/purification technologies. It minimizes contaminants by oxidation-reduction process, during which free electrons are transferred between molecules, making harmful substances benign. Medium is 100% recyclable, has no chemical additives, and can remove up to 98% of water-soluble lead, mercury, nickel, and chromium. |
 Oil Purification System suits aggressive applications.ISOPur Fluid Technologies, Inc.
Rocky Hill, CT 06067
Jul 14, 2005 Utilizing Balanced Charge Agglomeration (BCA™) technology, HR-Series removes and prevents sludge and varnish buildup on critical machinery internals while purifying lubricating and hydraulic fluids. PLC control and display monitors fluid temperature, pressure, flow, and total volume; indicates filter capacity and required change-out; and provides auto shutdown for specific conditions. With 20 gpm flow-rate, system is effective on soft and hard particles. |