Filters and Regulators suit critical in-plant applications.Parker Hannifin Corp., The Filtration & Separation Div.
Tewksbury, MA 01876
Mar 16, 2009
Constructed in 316 SS or zinc alloy, Filter Regulators offers flow rates from 16-72 scfm and feature rolling diaphragm for accurate pressure regulation regardless of changing flow or inlet pressure. Suited for harsh environments such as chemical washdown areas, Mini Filters come in 316 SS and zinc alloy with coalescing filter media. Five regulator models are available in stainless steel and aluminum with ¼-1½ in. ports, max pressure capacity of 300 psig, and flow rates to 300 scfm.
|
Switch Filter Modules suit multiband, multimode 3G handsets.RF Micro Devices, Inc.
Greensboro, NC 27409-9421
Mar 04, 2009
Along with single-pole nine throw pHEMT switch, RF1194 integrates quad-band GSM/GPRS/EDGE transmit low-pass filtering and 4 GSM/GPRS/EDGE receive surface acoustic wave filters. Model RF1195 integrates single-pole ten throw pHEMT switch and builds on RF1194 architecture by providing additional high-linearity port for 4 total symmetrical WCDMA/HSPA+ Tx/Rx ports. Both cellular switch filter modules come in pin-to-pin compatible, 4.5 x 4.5 x 1.2 mm packages.
|
Concentrator is suited for handling heat-sensitive samples.Labconco Corp.
Kansas City, MO 64132 2696
Mar 04, 2009
Along with refrigeration capability for protecting heat-sensitive samples by cooling them down to 25°F during processing, Proteomic CentriVap® Benchtop Concentrator System incorporates DNA Rotor that handles up to 60, 1.5 ml and 72, 0.5 ml microcentrifuge tubes. CentriVap Cold Trap, also included, reaches -58°F for solvent recovery and traps moisture, vapors, and corrosive fumes as they evaporate. MPU-controlled, 300 W heater accelerates evaporation with constant heat up to +100°C.
|
 Automatic Self-Cleaning Filter conserves water.Orival, Inc.
Englewood, NJ 07631
Mar 03, 2009
Featuring max capacity of 1,760 gpm, 10 in. ORG-100-LS filter stays online during 15 sec cleaning cycle without disrupting flow or pressure downstream. It uses 80% less water (typ) to clean itself when compared to similar-sized automatic filters. Along with cooling water, industrial process water, and reuse water, applications include irrigation, MF/UF/RO membrane pre-treatment, leach mining, and spray nozzle protection.
|
 Duct Filter removes excess vapors/mist from air stream.Nordfab Ducting
Thomasville, NC 27361
Feb 24, 2009
Mounted horizontally or vertically, Mist Recycler removes airborne liquid near pick-up point in air stream to promote filtration system efficiency as well as reduce moisture accumulation, leaks, and bacterial growth. Removable impingement baffle pre-filters vaporized water, oil, and grease from air stream, minimizing amount of liquid entering primary mist collector and extending filter life. Liquid collected in Mist Recycler drains into sump and is returned to machine.
|
 Air and Gas Filters suit harsh environments.Parker Hannifin Corp
Greenfield, TN 38230
Feb 23, 2009
Constructed of 304 Stainless and available in ¼-1 in. line sizes with flow capacities to over 700 Scfm, Balston® filters remove 99.99% of oil, water, rust and pipescale particles of 0.01 micron in size and larger from compressed air and gases. Filters suit applications in hospitals, food and beverage, chemical plants, refineries and pulp and paper mills.
|
 Mist Collectors clear air of oils and coolants.Donaldson Australasia Pty Ltd
Wyong Australia
Feb 13, 2009
Dryflo collects mist generated by coolants and machining oils that pollute atmosphere and condense on surfaces. Combined with special outer wrap, and allowing gravity to aid drainage by sitting vertically inside collector, Dryflo prevens collected liquid from re-entering clean air stream. Differential pressure gauge indicates pressure drop correlating with filter exhaustion, while filter retention system enables rapid filter change and minimal human contact with collected oil.
|
Filtration Unit withstands system pressure up to 6,000 psi.Schroeder Industries LLC
Leetsdale, PA 15056-1025
Feb 11, 2009
Featuring sensor and EasyTest(TM) fittings, ET-100 can be used to troubleshoot in instances of poor systems performance or excessive machine downtime, to check performance on production line, and to check systems before and after rebuild. It can be used with large meters that are clearly marked with scales. Pressure bearing parts are thick-section aluminum extrusions, and load control knob and scale selector switches are designed to provide grasp under any conditions.
|
Filter provides high-pressure reverse-flow filtration.Schroeder Industries LLC
Leetsdale, PA 15056-1025
Feb 11, 2009
Designed for hydraulic filtration, BHF 60 offers inlet/outlet port options including SAE 4-bolt flange code 62 and SAE ports that allow installation without adapters. O-ring seals are available in Buna N, Viton, and EPR for compatibility with petroleum oils, synthetic fluids, water-glycols, oil/water emulsions, and high water base fluids. Other features include magnetic actuation, screw-in bowl mounted below filter head, and optional poppet-type bypass valve.
|
Gas Turbine Inlet Filters survive harsh environments.GE Energy Services
Liverpool, NY 13088
Jan 20, 2009
Suited for self-cleaning applications, Nanomedia LP9 pulse filter cartridge utilizes Nanomedia technology to deliver sub-micron particulate removal, with initial efficiency greater than 80% at 0.3 microns, and is rated MERV 15. Minipleat filters F8MX and F9MX, rated MERV 15 and 16 respectively per ASHRAE 52.2, are designed for low pressure loss and provide dust-holding capacity that prolongs filter life. They suit operating environments across power generation and oil/gas industries.
|
 Disposable Adsorption Filters remove vapors from gases.Parker Hannifin Corp.
Cleveland, OH 44124-4141
Jan 02, 2009
Constructed of nylon and supplied standard with ½ in. tube connections, Balston® In-line Disposable Adsorption Filters are capable of handling operating pressures up to 50 psig in gas service and up to 70 psig in liquid service. Examples of removable vapors include hydrocarbons, ketones, CO2, ammonia, mercury, methane, ethylene, methanol, and water vapor. Areas of use include sample analyzing, venting applications, emissions monitoring, and direct food contact applications.
|
 Membrane Filters are custom die-cut.Interstate Specialty Products
Sutton, MA 01590
Dec 12, 2008
Custom Die Cut Membranes are suited for filtering fluids and gases or venting in medical, pharmaceutical, life sciences, and laboratory equipment. They are manufactured from PTFE, nonwovens, and other materials, and can incorporate intricate shapes, including narrow cross sections and close hole spacing. Membranes are supplied on rolls, with or without adhesive backing, and can be produced from a dxf, pdf, or most any drawing file and material supplied or specified by customer.
|
 Filters have pre-formed conical shape.Xenosep Technologies LLC
Boonton, NJ 07005
Dec 05, 2008
Suited for organic extract drying applications and designed to fit in funnel perfectly every time, FunnelFit(TM) Pre-Formed Conical Filters eliminate need for solvents used to wet down and keep quadrant folded or pre-pleated filters in funnel. Available in 3 quantitative ashless grades, flters are packaged in stacks of 100.
|
Filter Element can be used as charge/return line filter.Schroeder Industries LLC
Leetsdale, PA 15056-1025
Nov 26, 2008
With max flow rating of 35 gpm and max operating pressure of 580 psi, GH Hydraspin Filters protect fluids in feed circuit of hydrostatic drives and continuously variable transmission (CVT) applications. Visual and electrical indicator options, along with full range of cartridge style element options, are available. Cartridge style element with integrated bypass valve comes in various media grades that can be application-specific.
|
 In-Line Filters are easily connected and disconnected.Industrial Specialties Mfg, Inc.
Englewood, CO 80110
Oct 15, 2008
Featuring end connections in OD sizes of ¼, 5/16 and 3/8 in., push-to-connect in-line filters are available in sizes ranging from 20-250 micron. They are designed with John Guest® push-to-connect style fittings integrated into Celcon® plastic filter housing. Units can be customized to meet requirements for air, vacuum, and some fluid applications.
|
Filter Cartridge reduces hydrocarbon contamination up to 95%.Pentair Industrial
Sheboygan, WI 53082
Oct 07, 2008
Constructed from modified cellulose-based filter media, Carbflex(TM) OAC-20BB oil absorbing filter cartridge allows filter media to chemically bond with hydrocarbons instantaneously, absorbing up to 95% of total hydrocarbons in single pass. Unit removes dissolved and dispersed oils for applications including auto service stations, car and truck washes, oil and gas facilities, machine and repair shops, shipping bilge water and surface water runoff at truck stops.
|
Liquid Filtration System has vertical rack design.Pentair Industrial
Sheboygan, WI 53082
Sep 15, 2008
Along with quick-change design for cartridge replacement, Aqualine® features 8 in. dia fiberglass housing available in 60 in. length with pleated cartridge construction and outside-in flow pattern that optimizes flow rates and minimizes pressure drop. Vertical rack design allows housings to be stacked, increasing flow while saving plant floor space. Areas of use include high-flow-rate applications, including food and beverage, chemical, cosmetics, and electronics.
|
Snap-In Pleated Bag features integral venturi.Menardi
Trenton, SC 29847
Sep 09, 2008
Utilizing moisture-resistant, spunbond polyester media for 99.9% efficiency, Mikro-Pleat V-Series incorporates full diameter venturi that is pressed into filter element's flexible head and bonded in place. Shape of venturi helps capture pulses from blow pipe nozzles that are worn or not perfectly aligned. During normal filter operation, venturi smoothes air flow, which minimizes pressure drop arcross orifice.
|
Purification System clears process gases of metal/moisture.Matheson Tri-Gas
Montgomeryville, PA 18936
Aug 19, 2008
Combining chemisorption and physisorption, PICO-TRAP Ultra-Purification System removes volatile metal impurities and moisture from critical process gases used by semiconductor manufacturers. It features cryogenic, fully-regenerable purification column and can remove moisture down to less than 20 ppb in hydrogen chloride. Applied to a variety of gases, system also removes volatile metals including iron, molybdenum, chromium, titanium, nickel, and manganese.
|
 Base-Ported Hydraulic Filter has up to 500 gpm flow capacity.Schroeder Industries LLC
Leetsdale, PA 15056-1025
Aug 06, 2008
Suited for mining, steel mills, and pulp and paper applications, Model QLF15 is equipped with fast acting stainless steel bypass valve. Offered in re-cleanable metal mesh, plastic coreless, or deep-pleated media for high dirt holding capacity, it has maximum operating pressure of 1,500 psi and temperature range of -20 to 225°F. Available in 16 and 39 in.sizes, hydraulic filter features L-ported design, porting base and cap of ductile iron, and element case of steel.
|