Motor-Blower handles high thermal environments.AMETEK Commercial Motors
Kent, OH 44240
Jan 02, 2007
GEN II INFIN-A-TEK switched-reluctance motor-blower incorporates digital speed control, microprocessor-based controller, multi-phase bearing alignment, and air-seal protection system. Unit features built-in ac power supply and is offered for 120 and 230 V, 1- and 2-stage fan systems. Series includes 5.7 and 7.2 in dia tangential bypass and 5.7 in. dia Acustek® low-noise peripheral bypass discharge models; and 9.1 in. dia high-suction and high-airflow FLO-TEK(TM) tangential bypass models.
|
Blower Units have compact, transportable design.Aerzen USA Corp.
Coatesville, PA 19320
Dec 12, 2006
Designed for minimal noise output, Delta Blower Generation 5 has no absorption material in base/discharge silencer and ventilates Aerzen acoustic hood via mechanical fan installed on blower shaft. Design permits side-by-side installation, and oil level can be viewed and checked from outside while unit is operating. Offering optimal accessibility for maintenance, series includes 9 sizes for intake volume flows from 35-2,100 icfm and pressures to 15 psig.
|
 Airduster removes dust from electronic equipment.Electrolube (A division of HK Wentworth Ltd)
Swadlincote, Derbyshire DE11 0AN United Kingdom
Nov 08, 2006
EADPI invertible Airduster produces high pressure blast to remove dust and airborne contamination from delicate and inaccessible areas of electrical and electronic equipment. Aerosol is comprised of pure, compressed, inert gas, and is also non-flammable, non-CFC, and non-HCFC. It can blast off water and other solvents after cleaning, and cleans heads of disc drives, inaccessible assemblies, and photographic equipment.
|
 Utility Blowers feature adjustable airflow direction.Airmaster Fan Co.
Jackson, MI 49203
Sep 21, 2006
Model UB180 and UBH180 Portable Utility Blowers feature 300 CFM, 3-speed dial switch, 8½ ft cord with grounded plug, impact resistant housing, and two 120 V receptacles. Resetable circuit breakers and carrying handles are also featured in compact blowers. Model UBH180 is available with 4500 BTU heater.
|
 Rotary Lobe Blowers range from 5-200 hp.Kaeser Compressors, Inc.
Fredericksburg, VA 22404
Aug 10, 2006
Featuring tri-lobe Omega Plus profile, Com-paK Plus Blowers are equipped with generously sized motor, silencers, instrumentation, and valves. All maintenance points are accessible through canopy on front, and all power and process connections are at rear, allowing multiple units to be mounted side by side. Standard sound dampening enclosure lowers typical noise levels to 75 dB(A) or less, while integral ventilation fan provides cooling, even under extreme load conditions.
|
Make-Up Air Unit is designed for commercial kitchens.Greenheck
Schofield, WI 54476 0410
May 12, 2006
ETL listed to ANSI Z83.4 and CAN 3.7, Model DGK is direct gas-fired make-up air unit that features cast aluminum burners with SS mixing plates, Maxitrol electronic modulation burner control, and 25:1 turndown ratio. Manufactured for weather resistance, unit's housings and filtered weather hood are constructed of heavy gauge G90 galvanized steel. Airflow volumes range from 800-4,500 cfm with heating capacities up to 400,000 BTU/hr.
|
 Air Moving Fan features quiet operation.Continental Fan Mfg. Inc.
Buffalo, NY 14215
May 11, 2006
Using backward curved airfoil impeller manufactured of glass reinforced polyamide, TFD Blower pushes air through with minimal turbulence and noise. Product features cast aluminum impeller hub, epoxy coated steel housing, flanged and drilled outlet, and ABS inlet cone. Fan, suitable for 0-160°F, is available with single- or 3-phase TEFC motors and CW rotation to 5 positions. Applications include electronic cabinet cooling, heat exchangers, and fume hoods.
|
Centrifugal Blowers move high-temperature air.Fasco Motors Group
St. Clair, MO 633077
Dec 07, 2005
Constructed with aluminized steel housing that resists corrosion in mild acidic atmospheres, C-Frame centrifugal blowers handle air temperatures in excess of 500°F. Outputs range from 10-100 cfm, and continuous-duty motors are self-cooling and thermally protected. Available in sleeve or ball bearing designs, products are suited for moving high-temperature air in applications such as mid-efficiency furnaces, solid fuel heating, and commercial cookers.
|
 Blower Heater offers horizontal or vertical airflow.Chromalox
Pittsburgh, PA 15238
Nov 08, 2005
Mounted on wall or ceiling, Model HVH features epoxy-sealed elements to minimize false trips on ground fault equipment, pilot light to indicate normal operation, and adjustable On/Off electronic fan time delay control. Outlet screen prevents objects from coming in contact with fan, while door at bottom and removable case front facilitate access to internal components. Optional controls are provided for adjusting, monitoring, and operation of heater.
|
 Motor-Blowers target portable machines.AMETEK Commercial Motors
Kent, OH 44240
May 25, 2005 FLO-TEK 700™ Motor-Blowers are available with brushless or brush-type drive motor. Fan and housing design is optimized for performance in range of 70–90 in. sealed vacuum up to 300 cfm. Approximately 10 in. in diameter and height, blowers are available in 120 and 240 single-phase ac and 24, 36, and 48 dc voltages. They are suited for central vacuums, material handling, food service equipment, car washes, business machines, and animal grooming. |
 Plastic Blower delivers up to 979 cfm.Allegro Industries
Garden Grove, CA 92841-1410
May 11, 2005 Eight inch Compaxial Blower features 1/3 hp motor and 9-blade polypropylene fan encased in powder-coated steel grill. Blower and canister are corrosion-, UV- and chemical-resistant polyethylene with handles for transport. Unit can be set up to ventilate or evacuate airflow with canister locking system. Design allows user to remove canister and ducting from outlet side and attach it to inlet side in seconds. Weather-resistant canister houses 15 and 25 ft ducting. |
Rotary Lobe Blower is 6 in. long and weighs 1.75 lb.Thomas Products Division
Sheboygan, WI 53081
Apr 27, 2005
Utilizing assembly process that minimizes leak paths within blower chamber, compact RL Series blower delivers air flow up to 2 cfm, pressure to 2 psi, and vacuum to 4 in. hg. It can be mounted either vertically or horizontally, and is equipped with standard 3/8 in. OD hose barbs and 6 in. wiring harness. With 12 V brushless dc motor and permanently lubricated timing gears, blower is for suited for use in variety of portable air-moving devices.
|
 Regenerative Blower features closed-loop control.All-Star Products Inc
Memphis, TN 38138
Apr 08, 2005 Maxi-Aeration DO System optimizes aeration process by maintaining set-point dissolved oxygen rate in aeration basins. VFD continuously monitors DO levels to provide optimum oxygen level for bacterial growth. Unit is rated for applications up to 1,450 scfm, 11.5 psi, and 150 hp. |
 Blower Heater suits harsh environments.Chromalox
Pittsburgh, PA 15238
Apr 01, 2005 Corrosion-resistant Model HD3D provides comfort heating and freeze prevention in harsh, corrosive, dirty, and wet environments. With stainless steel brackets, hose-down unit can be directly mounted to wall or ceiling. NEMA 4X control box is located on front of heater. Wiring connector provides watertight seal in event of replacement of motor, limit control, or elements. Heater is suited for wastewater treatment plants, steel mills, ships, car washes, and foundries. |
Regenerative Blower suits concrete applications.AMETEK Rotron Technical & Industrial Products
Kent, OH 44240
Mar 30, 2005
Offered as drop-in replacement for DR 707 regenerative blower, DR757 features compact construction and is powered by 4 hp motor that draws less than 7 A. Design, based on sound attenuation method, utilizes noise cancellation technology; further reductions are achievable through use of sound enclosures.
|
 Dual-Wire Brushless DC Blower has compact design.Servo Magnetics, Inc.
Canoga Park, CA 91303
Jan 20, 2005 DC blower incorporates embedded drive and commutation electronics in brushless design, providing 2-wire input. Impeller and rotor are balanced to provide vibration-free, low-noise operation. With 2.9 in. dia and 2.8 in. long design, 12 V unit produces 10 in. of H2O pressure and has max flow rate of 18 cfm. Windings for other voltages are available upon request. Product suits applications where noise and longevity are issues. |
 Regenerative Blower delivers 1,550 scfm and 8.5 psi.All Star Products, Inc.
Memphis, TN 38138
Sep 01, 2004 Rated from 20–75 hp, Big Bertha is available in direct drive or packaged v-belted arrangement. Unit can replace existing rotary blowers and multistage centrifugal blowers used in municipal and industrial aeration and material handling applications. |
 DC Fans and Blowers suit electronics applications.Arconix Group
Oxnard, CA 93030
Aug 26, 2004 Arconix® brushless DC fans are available in 13 different sizes from 25–172 mm with thicknesses from 10–51 mm. Offered with choice of 7 housing types, products operate at speeds from 1,600–13,000 rpm with airflow capabilities from 1.49–121 cfm. Arconix DC blowers deliver concentrated spot-cooling at noise levels down to 21.61 dBA. They are available 5, 8, 9, and 12 cm sizes with speeds from 1,600–5,000 rpm and flow rates to 42 cfm. |
 Air Blower keeps machine window clear of debris.EXAIR Corporation
Cincinnati, OH 45249-1621
Aug 06, 2004
With no moving parts, Air Disk Window Blowoff keeps window of machines clear of coolant, chips, and debris, ensuring process and part visibility at all times. Compact disk delivers 360° airstream that blows out across entire window surface. Using proprietary airflow technology, disk ejects compressed air through thin-slotted ring nozzle. Peel and stick adhesive permanently bonds aluminum Air Disk to glass or polycarbonate surface.
|
Exhaust System suits laboratory applications.Greenheck
Schofield, WI 54476 0410
Jul 01, 2004 Self-contained, Vektor™ High Plume Dilution Blower employs discharge nozzle design that entrains additional ambient air to mix with potentially hazardous exhaust fumes. Additional air dilutes lab effluent, displacing exhaust high above roof and away from building makeup air systems. Mixed-flow impeller is available in AMCA type C or type B spark-resistant construction, for laboratories that exhaust flammable and explosive solvent vapors. |