|
|
|
HVAC ->
Ventilation Equipment ->
Air Cleaners & Filters
Air Cleaners & Filters
(Showing headlines 81 - 100) 1 2 3 4 5 6 7 8 9
|
 Air Cleaner offers long-reach flexible hose attachment.Micro Air Clean Air Systems
Wichita, KS 67205
Nov 23, 2004 TaskMaster TM 1000 is available with 15 or 25 ft long hose that reaches across obstacles or into tight areas. Attachment includes removable hood and is suited for capturing airborne pollutants during cutting, welding, and grinding operations. With 25½ x 32½ in. footprint, Model T 1000 operates on 120 V or optional 208/230–460 V. It includes 1,000 cfm motor-blower assembly and dual cartridges with Roto-Pulseâ„¢ cartridge cleaning system. |
 Mist/Smoke Eliminator is rated up to 1,000 cfm.Air Quality Engineering, Inc.
Minneapolis, MN 55428
Nov 08, 2004 MistBuster Infinity utilizes 2-stage filtration process to eliminate mist and smoke from airstream. During first stage, mechanical mist impingers capture larger mist droplets, which are coalesced and returned to coolant sump. Second stage uses proprietary media with 288 ft² cleaning area. Since variable-speed motor and impeller are on clean air side of unit, dirty air will not contaminate motor or cause impeller to go out of balance. |
 In-Line Filters handle air, vacuum, or liquids.Industrial Specialties Mfg., Inc.
Englewood, CO 80110-4363
Oct 29, 2004 Available in 20, 65, 105, 150, and 250 microns, High-Flow Filters are molded in polyoxymethylene acetal with nylon or polyester screens and color-coded frames that indicate filter micron size. Filters are offered with ¼, 5/16, and 3/8 barbs; 10–32, ¼â€“28, and 1/8 female threads; and 1/16 and 1/8 male threads. They are suited for chemical solutions, ink, water, oil, gasoline, fuel, and alcohol. |
 Oil Mist Air Cleaner features direct-drive fan.Micro Air Clean Air Systems
Wichita, KS 67205
Oct 18, 2004 Model OM6000DD captures airborne oil-mist through combination of baffle type oil impingers and oil-mist bag filters. Captured oil drains to bottom of unit and out oil drain. Featuring multiple pick-ups and hinged door that provides air bypass, Model OM6000DD offers capacity up to 6,000 cfm, depending on diameter of 3 inlet plenums. Options include HEPA filter, overload protector, silencer, and floor-mount stand. |
Electrostatic Replacement Filter suits OEM applications.Trion, Inc.
Sanford, NC 27331
Oct 08, 2004 Air Boss® ES CELL-G is a dual-voltage, electrostatic replacement unicell that captures airborne particles as small as 0.01 micron with up to 95% DOP efficiency. It features high-voltage standoff ceramic insulators and spiked ionizer blades instead of wires. Consuming 75 W max at 120 Vac, unit features ionizer voltage range of 10–12 KVdc and collector voltage range of 5–6 KVdc. Max airflow temperature through cells is 140°F and max cell washing temperature is 160°F. |
Air Filters protect 1U- and 2U-high rack-mount electronics.Universal Air Filter Co.
Sauget, IL 62206
Sep 22, 2004 Rackmount Air Filters are available with choice of aluminum frames, EMI shielding screens, and media, including cleanable, UL 94 HF-1 rated Quadrafoam filter media. Fully framed, cleanable filters operate under high shock and vibration conditions in dust-contaminated environments and meet environmental and safety requirements of Telcordia NEBS and UL/CSA 60950. Applications include data centers, telecommunications central offices, and CATV headends. |
Woodworking Tools target novices and professionals.Delta Machinery
Jackson, TN 38302-2468
Sep 01, 2004 Pneumatic ShopMasterâ„¢ line includes 1¼ in. brad nailer, 2-in-1 nailer and stapler, 1 in. narrow crown stapler, and 1¼ in. brad nailer and compressor combo kit. Units offer tool-free depth adjustment, 360° adjustable exhaust, and sequential trigger. Hybrid Style Cabinet Saws have enclosed base with removable dust chute, 1¾ hp motor, hinged motor cover, and choice of three 30 in. fence options. Equipped with 1 micron filtration bag, Dust Collectors come in 6 models that filter 1,200–4,600 cfm. |
Air Purification System suits commercial kitchen use.Trion, Inc.
Sanford, NC 27331
Aug 30, 2004 Electrostatic AIR BOSS® KES Series helps assure that exhaust from commercial kitchens meets acceptable clean air standards. Unit can be customized for specific applications and is available in several capacity ranges. Typical applications include restaurants, food courts, hospitals, and schools, including colleges and universities.
|
Fan-Coil UVC Kit controls mold and indoor air quality.Steril-Aire, Inc.
Burbank, CA 91504
Aug 13, 2004
Fan Coil UVC Kit contains UVC Emitter(TM) and power supply, plus all necessary hardware components to retrofit fan coil with UVC. Emitter tubes, available in 6 lengths from 16-42 in. and installed across from cooling coil, irradiate high output UVC energy to eliminate surface contaminants and reduce airborne microbial contaminants. Applications include hotels, schools, apartments, office buildings, patient rooms, or anywhere fan coil units are located.
|
 Air Filter eliminates odors using two processes.Airguard Industries, Inc.
Louisville, KY 40218
Jul 28, 2004 Available in 2 and 4 in. thicknesses, Fresh Air Supreme uses chemically-enhanced carbon to remove odors and compounds, including diesel fumes, mercaptans, sulphurous odors, hydrogen sulfide, acid gases, and VOCs. Unlike conventional activated carbon that relies exclusively on physical adsorption, media used in Fresh Air Supreme captures odors through chemical reaction and adsorption. Media is self-supporting and does not require metal backing to shape pleats. |
 Mist and Smoke Collectors suit metalworking industry.Royal Products, Div. Curran Mfg. Corp.
Hauppauge, NY 11788
Jul 14, 2004 Filtermist FX-Series eliminates oil mist and smoke produced in turning, milling, and grinding applications within metalworking industry. Product use results in safer work environment in compliance with OSHA and NIOSH air quality standards. Available in 4 sizes from 275–1,200 cfm, units can be direct-mounted, suspended from ceiling, or mounted on floor stand. Stainless steel models are also available. |
 Air Filter offers 4 efficiencies up to 99%.Camfil Farr Company
Jonesboro, AR 72401
Jun 23, 2004 V-bank Durafil® Air Filter features high-impact plastic frame and media pack supports for resistance to corrosion. It uses water-resistant glass media in pleat-in-pleat design with up to 200 sq ft of media area. Suited for variable air volume systems, filter handles airflow capacities up to 3,000 cfm, with final pressure drop capability to 2.0 in. wg. Four efficiencies include MERV 11, 13, 14, and 16 based on ASHRAE 52.2 (60–65%, 80–85%, 90–95%, and 99%). |
 Air Filters withstand harsh environments.Universal Air Filter Co.
Sauget, IL 62206
Jun 15, 2004 Tough Air Filters protect electronic components that utilize forced air thermal management to keep cool and functional. Products withstand environments with high temperature/humidity, chemicals, or solvents, and can provide EMI/RFI shielding along with particulate protection. Suited for indoor and outdoor use, filters incorporate Quadrafoam II media and chromated, epoxy powder coated, or anodized aluminum frames and grid systems. |
Air Filters include flame and fungus protection.Universal Air Filter Co.
Sauget, IL 62206
May 11, 2004 Suited for medical electronics enclosures, WrapAround Air Filters with Quadrafoam filter media feature flame-resistant coatings and anti-microbial additives with fungus growth rating of zero. Frame-n-pane design integrates aluminum or stainless steel frame and series of crossing, reinforcing intermediates that provide media support. Frames are available with finishes that protect against corrosion and provide EMI/RFI shielding. |
 Self-Cleaning Filter operates continuously.RPA Process Technologies
Portage, MI 49024
May 10, 2004 Mechanically cleaned Model MCF utilizes magnetically coupled drive technology that moves 4-way, spring-loaded cleaning disc without need for external shaft or drive seals. Disc travels up and down inside filter media, removing collected contaminants. By utilizing cleanable, permanent media, downtime and filter disposal are eliminated. Filter is suited for highly viscous liquids such as paints, adhesives, resins, inks, and other similar materials. |
Air Cleaner eliminates odors and VOCs.Air & Water Solutions
Nutley, NJ 07110
May 06, 2004 CAPâ„¢ Clean Air Plant model CAP-600 is portable bio-oxidizer that controls indoor air quality by destroying organic contaminants. Contaminants, along with odors that they generate, are attracted to clean air zone and oxidized. Clean air zone also reduces intensity of sudden release of air toxins, while rapidly deteriorating toxic levels of contaminants. It requires no elevated temperatures, pressures, or excess energy to operate. |
Air Filters feature MERV 8 DuraFlex® media.AAF International
Louisville, KY 40223 6169
Apr 28, 2004 PerfectPleat ULTRA Filters provide MERV 8 efficiency without use of electrostatic charge, which can cause degradation. Intersept® antimicrobial is incorporated to preserve media throughout service life. Available in 1 and 2 in. depths, filters can be identified by blue media tint on air-leaving side. They offer optimum pleat spacing and media consistency for maximum airflow and dust holding. |
 Compressed Air Filters provide consistent air quality.Kaeser Compressors, Inc.
Fredericksburg, VA 22404
Apr 23, 2004 Compressed Air Filters feature housings with large flow areas to ensure low pressure drop. Filter element is manufactured using matrix blended fiber that causes consistent pore size within media. A 96+% void space minimizes pressure drop, while maintaining high capture rates and filtration efficiencies across range of flows from 20–21,250 scfm. |
Filtering Units offer contaminant-free material application.DeVilbiss Industrial Spray Equipment, ITW Industrial Finishing
Glendale Heights, IL 60139
Apr 09, 2004 CleanAirâ„¢ Filtering Units are suited for finishing industry, where high solids and waterbornes are extremely sensitive to contaminants. Centrifugal Filter-Regulators filter out water and oil aerosols and dirt particles up to 5 microns. Coalescer Filter-Regulators remove water, dirt, and oil down to .01 micron. Three-Stage Desiccant Units offer particulate removal to 5 microns, .01 micron, and water vapor filtering to dew point of -40°F. |
 Replaceable Duct Filter supplements primary filter systems.DuctSox
Dubuque, IA 52002
Apr 05, 2004
Designed for new or retrofit buildings with air dispersion, cone-shaped Final Filter is zippered within minutes into fabric duct system at inlet. It is available in NAFA-rated, MERV-8 or MERV-12, non-woven, 3M filter media with 50% and 90% efficiencies, respectively. Multi-layer filter media withstands pressure loading while allowing depth loading. Depending on inlet velocity, media, and sizing, filter will generate 0.24-1.98 in. wg resistance to airflow.
|
(Showing headlines 81 - 100) 1 2 3 4 5 6 7 8 9
|
|
|