Ventilation Equipment

Thermal & Heating Equipment, HVAC, Green & Clean

Packaged Heat Exchangers heat and cool residences, businesses.

April 23, 2015

Available in cooling with gas heat configuration, 2- to 5-ton capacity York LX Series heats and cools residential and light commercial buildings. Single-cabinet design, featuring exact-fit gas/electric hookups, facilitates installation and service. With 14 Seasonal Energy Efficiency Ratio rating, packaged units exceed US Department of Energy efficiency standards and feature corrosion-resistant copper tube/aluminum fin condenser coils, single-stage compressor, and single-stage gas heat.
Read More

Fluid & Gas Flow Equipment, HVAC

Fume Extraction Filters provide 31 sq-ft of filter media.

April 23, 2015

Available for FILTAIR® 130 portable fume extractors, FILTEK™ XL Filters double lifecycle compared to previous filter styles and feature MERV rating of 15, ensuring capture of smallest weld fume particles ranging from .3 to 1 micron in size. FR-treated replacement filters can be cleaned manually with dry, compressed air. Filter service indicator light on fume extractor indicates when this routine maintenance should be performed. Read More

HVAC

Fume Extraction System comes in 208-230 V single-phase model.

April 20, 2015

Equipped with ZoneFlow™ technology, FILTAIR® Capture 5 provides weld fume capture area up to 5 ft away. ZoneFlow extends capture distance by way of negative pressure zone that is designed to take air into extraction arm at 900 cfm and release filtered air at approximately 90° angle. System also utilizes FilTek™ XL filters that are rated at 15–16 on MERV scale. Operating after each shutdown, automated pulsed cleaning cycles help extend filter life and simplify maintenance. Read More

HVAC

Air Purifier reduces spread of Super Bugs in hospitals.

April 20, 2015

Offering tabletop or bedside purification, Airocide® DS uses photocatalytic biocide reactor to eliminate viral, fungal, and bacterial pathogens from air. Unit converts dangerous bacteria, viruses, and destructive VOC's into harmless water vapor without producing ozone. By destroying all organic matter less than .3 microns in size, filter-less purifier produces air that is 99.999% pathogen-free, and can also reduce surface contamination by removing airborne organisms that settle on fomites. Read More

Waste Handling Equipment, Welding Equipment & Supplies, HVAC

Extraction/Filtration Systems remove fumes, dust, smoke.

April 17, 2015

Able to be flexibly adapted to various process conditions, ULT 1500 and ULT 2500 remove and filter hazardous substances in dust, laser fume, and welding smoke. Geometry of conic filter cartridges increases filter performance and cleanability, and dust deposits are collected directly in 70 l removal container for low-contamination disposal. Rotary nozzle dedusting reduces compressed air consumption, and filtered air can be fed back to working area to avoid heat loss. Read More

HVAC, Chemical Processing & Waste Management, Fluid & Gas Flow Equipment

Synthetic Dust Collector Filter offers moisture resistance.

April 8, 2015

Suitable for harsh, humid environments, HemiPleat® Synthetic is washable and can handle heavy dust loading conditions and/or hygroscopic or sticky dusts. Filter uses lightweight, 100% spun bond polyester media in pleated design that maximizes surface area while maintaining open pleat spacing for optimized dust release during pulse cleaning. Suited for applications up to 160°F, HemiPleat Synthetic comes in standard and nano fiber media versions with MERV 11 and MERV 15 ratings, respectively. Read More

HVAC

Mobile Extraction and Filter Unit operates contamination-free.

April 1, 2015

Able to be maneuvered by hand, MaxiFil Clean protects against welding fumes by collecting pollutants at their point of origin. Flexible extraction arm comes in lengths up to 4 m and allows use in different positions, while filter is integrated as cartridge, has area of ~15 m², and cleans itself automatically during operation. More than 99.97% of welding fumes containing respirable dusts <10 µm is separated. After filtering, unit automatically feeds dust particles to disposable cartridge. Read More

Electrical Equipment & Systems, HVAC, Green & Clean, Display & Presentation Equipment

Low-Profile LED Downlight accommodates shallow ceiling plenums.

April 1, 2015

With 3.5 in. profile housing, Aether downlight fits shallow plenums above .50–1.5 in. thick ceilings in residential and light commercial settings where there are HVAC ducts and heating/water pipes between floors. Energy Star®-rated and wet location-listed unit operates with 22.5 W, delivers up to 1,375 lm, and is available with 25° narrow or 40° flood beam. Color temperatures range from 2700K to 4000K, CRI is up to 90, and luminaire dims via an electronic low voltage or 0–10 V dimmers. Read More

HVAC

Energy Recovery Ventilator reduces building heating/cooling loads.

March 25, 2015

Utilizing total energy core, MiniCore provides 300–1,000 cfm of preconditioned, fresh outdoor air for commercial applications. Total energy core is constructed of hydroscopic resin material layered in cross-flow corrugated structure that separates supply and exhaust air to ensure only fresh air is introduced into indoor space. Horizontal or vertical mounting options as well as configurable intake and discharge connections facilitate installation and integration into various duct configurations. Read More

HVAC

Multi-Speed Blowers utilize electronically commutated motor.

March 20, 2015

Featuring weatherized, direct drive, non-explosion-proof design, Intelli-Sense Multi-Speed Blowers are controlled by 2- or 3-position switch. Units can exhaust fume hoods from 3–7 ft in width at full sash open height and 100 fpm face velocity. Phenolic coated steel models are recommended for low to moderately corrosive applications, while fiberglass units suit highly corrosive environments. For extremely corrosive atmospheres produced by high order oxidizers, PVC models are available. Read More

HVAC, Computer Hardware & Peripherals

CPU Cooler and Fan suit space-restricted systems.

March 20, 2015

With compact heatsink and 14 mm NF-A9x14 PWM fan, NH-L9x65 Cooler stands 65 mm tall, making it suitable for home theater PCs and Small Form Factor cases. Unit provides 4 heatpipes in 95 x 95 mm footprint, guaranteeing 100% RAM and PCIe compatibility on Intel-based ITX mainboards. Available in PWM version, 60 mm NF-A6x25 Fan has NE-FD1 IC for fully automatic speed control via 4-pin fan headers and comes with Low-Noise-Adapter to reduce max speed during PWM control from 3,000 to 2,300 rpm. Read More

HVAC, Laboratory and Research Supplies & Equipment, Green & Clean

Laboratory Hood contains chemical fumes and vapors.

March 18, 2015

Designed to operate at low air volumes, Protector® XStream® Laboratory Hood uses patented features that work together to reduce concentrations of contaminants in areas behind sash opening and near user's breathing zone. Upper dilution air supply bathes sash interior with clean air, eliminating chemical fumes along sash plane, while Eco-Foil air foil with Clean-Sweep™ openings minimizes energy consumption. Operating Protector XStream at OSHA-approved 60 fpm consumes only 690 cfm. Read More

HVAC, Chemical Processing & Waste Management, Fluid & Gas Flow Equipment

Filtration Systems support GFR plastic part production.

March 18, 2015

Suitable for production of glass fiber reinforced plastic parts, Extraction and Filtration Systems remove and intensively filtrate styrene, fine dusts, and chips from process air. Two-step design utilizes self-cleaning cartridge filters in first step and HEPA-type filters in second step to capture finest suspended matter. By ensuring binding of aggressive polyester dust mixture particles, metering device helps protect ducts and equipment against wear and extends filter life. Read More

HVAC, Laboratory and Research Supplies & Equipment

Laboratory Fume Hoods have chemical-resistant fiberglass liners.

March 17, 2015

Operated as low as 60 fpm, Protector® Premier® hoods have interior with molded, one-piece, fiberglass-reinforced polyester liner that offers fire-resistance and facilitated cleanup. Eco-Foil™ air foil, featuring Clean-Sweep™ airflow slots, lets clean air continuously flow through to create constant, protective barrier of protection from contaminants. Automatic air bypass system, preset fiberglass baffle, and vertical-rising tempered safety glass sash with cable pulley also are standard. Read More

Fluid & Gas Flow Equipment, HVAC

Backdraft Damper helps meet 2014 NFPA rquirements.

March 17, 2015

KB Duct Backdraft Damper helps installers meet 2015 NFPA requirements regarding installation of Explosion Isolation Device on all suction side ducts that transport material with KST value above zero. Constructed from heavy-duty welded steel, KB-NRV no-return explosion isolation valve protects workers and facilities from damaging effects of baghouse or filter explosion. Features include flanged inlet and outlet with coflanges, inspection access door, grounding lug, and locking mechanism. Read More

HVAC

Motorized Axials offer vibration-free operation.

March 16, 2015

Coupling DC motor and impeller to minimize space requirements, Models DXG and DXP are suitable for either supply or exhaust use, and in applications where transient electrical noise is prohibited. Both motor and impeller are located directly in air stream, providing heat dissipation and efficient motor cooling. Available in 24 and 48 Vdc, precision-balanced RoHS-compliant units feature 1–10 Vdc or PWM motor control and offer capacities up to 1,441 cfm. Read More

HVAC, Laboratory and Research Supplies & Equipment

Floor-Mounted Lab Hoods accommodate oversized apparatus.

March 12, 2015

Protector® XL bypass airflow fume hoods with chemical-resistant panel liners offer max visibility of 73.5 in. high. Allowing operation down to 60 fpm, hoods with vertical-rising sashes meet SEFA-1 standard. Widths of 4, 5, 6, and 8 ft are available. Containment-enhancing features include 2 tempered safety glass sashes with powder-coated aluminum sash handles and powder-coated steel sash tracks with Clean-Sweep slots. Hoods with 4 horizontal sashes are available in 8, 10, 12, and 16 ft widths. Read More

Fluid & Gas Flow Equipment, Chemical Processing & Waste Management, Green & Clean, HVAC

Particle Filtration System features 300 cfm airflow.

March 10, 2015

Working in conjunction with fJETXL and fJET-24 flatbed digital inkjet printers, Clean Air 300 uses combination HEPA and carbon tray for maximum removal of fumes and gases with high particulate content. System does not require any ventilation to outside, and connects via custom ports located above print heads which then connects via flexible hose. Using large filters for extended life, Clean Air 300 includes deep-bed gas filter, filter monitor gauge, and thermal overload protection. Read More

Cleaning Products & Equipment, HVAC

Wet/Dry Vacuum Cleaner operates in rugged environments.

March 10, 2015

Designed to collect dust, debris, and liquid in rugged environments such as building and construction sites, Eliminator Pro II delivers 130 cfm airflow while using 8.5 A of energy. Unit features 26 x 17 x 36 in. footprint and 12 gallon collection tank that is equipped with 32 mm drain hose. Multi-stage filtration system includes disposable bag (optional), cloth main filter, and HEPA filter cartridge. With tilting motor head, vacuum facilitates servicing. Read More

HVAC, Laboratory and Research Supplies & Equipment

Filtered Ductless Fume Hood helps laboratories conserve energy.

March 6, 2015

Designed for laboratories that are difficult to vent due to location, Protector® Echo™ operates independent of building's exhaust system and without removing tempered air from laboratory. Neutrodine™ filters handle jobs of 6+ other kinds of carbon filters, and sensor package, backup filters, and optional g-Guard® remote monitoring software work with range of chemicals. In case of chemical breakthrough or loss of airflow, alarm sounds and communication system alerts designated email address. Read More