 Air Temperature Control suits temporary heating applications.Chromalox
Pittsburgh, PA 15238
Jan 12, 2005 Electrically heated, 100% efficient HACS produces zero emissions. Available for up to 150 kW and 7,000 scfm air at 5 in. WG, unit is suited for temporary on-site comfort heat, curing plaster, drying paint, spot heating for personnel, and freeze protection for equipment. High limit temperature and low limit airflow controls ensure safety during operation. Painted carbon steel construction offers weather resistance, and all electrical enclosures are NEMA 4 rated. |
HVAC Controller offers flexible comfort control.Siemens Building Technologies, Inc.
Buffalo Grove, IL 60089
Aug 16, 2004 TALON® Predator® Three Zone Controller provides control of up to 3 rooms or zones, with simple setup of individual or averaged sensing, bypass override, and setpoint for each area. LonMark®-certified controller utilizes 6 input, 8 digital output, and 3 analog output platform that accommodates 3 room sensors along with existing 4 PID loops for general-purpose control and I/O point expansion for any points not used as part of application control. |
 Industrial Controllers feature remote setpoint capability.Danaher Industrial Controls
Gurnee, IL 60031
Aug 04, 2004 Designed to improve temperature and process control, + (Plus) Series includes 1/16, 1/8, and Ľ DIN size models 1160+, 1800+, and 1400+ respectively. Equipped with programming interface and plug and play options format, they provide flexible control over processes via dual setpoints that can be selected from remote location. Controllers feature PID control of processes, 3 programmable outputs, transmitter power supply option, and auto-detection of hardware modules. |
Evaporative Cooling Optimizer reduces water waste.Greenheck
Schofield, WI 54476 0410
Aug 04, 2004 Providing complete evaporative cooling control, Water Wizard™ measures outside temperature and humidity and adjusts water supply to provide required amount of water for maximum evaporative cooling. On cool or humid days, product reduces water supply, while on hot or dry days, it increases water supply to meet increased maximum cooling potential. Design facilitates accurate set-up and operation, and cooling levels can be adjusted in-field. |
 Temperature Controller ranges from 100–900°F.Selco Products Co.
Anaheim, CA 92805-4842
Apr 08, 2004 Microprocessor-based Model 2901 features max operating temperature of 158°F with 0–90% RH. Four-digit, .56 in. LCD displays temperature and time in low-light conditions. Available with temperature control only, or with time and temperature control, digital unit includes SSR drive output and 0.23 in. quick-connect input and output connections. Controller requires Type J thermocouple sensor and solid-state relay. Input voltage is factory-fixed or user-selectable. |
 Electronic Temperature Control is suited for boilers.Wayne Combustion Systems
Fort Wayne, IN 46803
Mar 23, 2004 Hydronix Triple Limit Boiler Control features multi-position mounting capabilities, aluminum casing, replaceable plug-in sensors, solid-state relays, and LED indicators with diagnostics. Redundant safety systems monitor relays and sensors and instantly detect errors. Computerized supervisory systems ensure that every aspect of control is operating properly before heat cycle is started. |
Switch combines temperature and level control.Norgren
Littleton, CO 80120
Dec 03, 2003 Temperature/Level Switch is available with variety of switching configurations and temperature settings. Floats are provided as normally open on stems, but can be reversed to normally closed when specified. Switch wiring and installation is through one opening. Suitable for water and hydrocarbons, switch has max operating pressure of 150 psi. Operating temperatures are from -40 to +225°F in oil and -40 to +180°F in water. |
 VAV Actuator provides open protocol control.Siemens Building Technologies Ltd.
Sudbury, ON P3A 2A3 Canada
Oct 27, 2003 Predator® VAV Actuator integrates LonMark® certfied VAV controller in OpenAir direct-coupled damper actuator designed for 3-position floating control. Unit provides control of pressure-independent, single duct VAV/CV zone boxes. Preprogrammed control logic is configurable for variety of applications, including cooling or heating, fan, occupancy, and lighting control. |
 Temperature/Process Control includes assured soak capability.Love Controls
Michigan City, IN 46361
Aug 28, 2003 Series 16S 1/16 DIN Ramp/Soak Profiler Temperature/Process Control includes variable time base, front panel run/hold key, auto/manual station, and peak and valley indication. High-speed switched Vdc output allows fast SSR loads. Inputs include Type J, K, T, E, L, N, R, S, C, or B Thermocouples; 100 or 1000 Ohm DIN Platinum RTD; 100 Ohm 0.00392 Platinum; 0–10 Vdc; -10 to +10 mVdc; or 4–20 mAdc. Single or dual set point outputs include relay, switched Vdc, SSR, or 4–20 mAdc. |
 Temperature Control System meets NFPA 79 safety standards.Mokon Div., Protective Closures LLC
Buffalo, NY 14207
Aug 06, 2003 Duratherm NPS negative pressure, temperature control system temporarily fixes cooling circuit leaks to allow production to continue through end of run. Incorporating venturi jet pump and reservoir, unit controls temperatures up to 180° by pulling rather than pushing water through process. Three-way flow control valve adjusts system from positive pressure when no leaks are present to negative pressure to stop leaks. |
Controller provides temperature management and recording.Yokogawa Corp. Of America
Newnan, GA 30265 1040
Jun 25, 2003 DAQSTATION CX1000 and CX2000 Style 3 units have controllers that integrate paperless recording function with control function and Ethernet interface. Users can perform control and measurement without need to create monitoring windows or program data acquisitions. Products offer support for running individual pattern control for 6 internal loops and incorporate measured/setting value calculation function as well as logic calculation function. |
 Control System regulates re-circulating system temperatures.Armstrong International, Inc.
Three Rivers, MI 49093
May 28, 2003 Electronic Mixing Center (EMC) combines integrated circuit board technology with precision hydraulics for water temperature control within institutional re-circulating hot water systems. Unit also employs building management system, PC interface capability, and site-programmable, high-temperature system flush for Legionella abatement. With overnight, low-temperature, energy-efficient mode options, product offers ±1°F control from 1–75 gpm. |
 Gas/Temperature Controls are integrated into one device.Fenwal
Ashland, MA 01721
Apr 28, 2003 Custom Gas Ignition and Temperature Controls operate with RTD, thermocouple, and thermistor sensors and combine direct spark or hot surface ignition with precise temperature control. They can provide single- and multi-speed fan control, custom temperature and ignition algorithms, GUIs and displays, LED diagnostics, and communications interface. Packaging options include standoff mounting, potting for extreme environments, and range of connectors and enclosures. |
 Control modulates infrared heating systems.Roberts-Gordon, Inc.
Buffalo, NY 14240
Feb 13, 2003 ULTRAVAC™ Control, for CORAYVAC® infrared heaters, can modulate burner input rate with outdoor air temperature to match heating system's input to building's heat requirement. Multi-feature zone temperature sensor provides localized control resulting in additional comfort for building occupants. PC-based software package provides total heating system management from user's desktop. Optional modem offers remote system management. |
 Microcontrollers maintain water temperature.HB Controls, Inc.
Bridgewater, MA 02324-4302
Jan 20, 2003 Microcontrollers, for use in instant hot water heaters for home, hotel, or industrial use, can be wired to circuit card in space-saving, wall-mounted heating unit programmed to maintain temperature within ±0.5°F. To save energy, temperature is maintained only as long as water flows. |
Temperature Control Unit offers vacuum option.Thermal Care Inc.
Niles, IL 60714
Dec 13, 2002 Oiltherm Hot Oil Temperature Control Unit circulates oil through process and automatically maintains oil temperature at selected setpoint. With vacuum option, venturi in Oiltherm allows oil to be sucked from mold, in preparation for mold changes or removal of unit. Positive/negative mode allows mold to run with leak. Unit includes stainless steel heat exchanger and can run continuously. It is suited for city water supply, water for chillers, and cooling towers. |
 Refrigeration Control Module features optional transformer.Mine Safety Appliances Co.
Pittsburgh, PA 15230
Nov 20, 2002 Chillgard LC Control Module, with transformer option, enables unit to power up to 6 remote Chillgard LS Photoacoustic Infrared Refrigerant Monitor sensors. Standard powering uses 24 Vac/dc. Unit works with Chillgard LS Refrigerant Monitor gas sensor modules to provide remote signaling and control capability in refrigerant monitoring applications. It communicates with up to 8 sample points from Chillgard LS Monitor over RS-485 communication line. |
 Temperature Control regulates from 6 to 12 zones.American MSI Corporation
Moorpark, CA 93021
Oct 25, 2002 Altanium® CM temperature control system mounts directly on mold junction-box and eliminates need for thermocouple cables. With width of 9.5 in., height of 9.7 in., and depth of 6.25 in., unit can fit on any hot runner mold system, leaving space for robots, optronics, and hoses. Transverse latching mechanism assures that control remains securely in place. |
 Temperature Control System suits semiconductor processing.Omega Engineering, Inc.
Stamford, CT 06907
Oct 21, 2002
OMEGA® iR2(TM) temperature measurement and control system uses 2-color ratio technique for temperatures from 300 to 3,000°C, even when measuring small, moving target with changing emissivity viewed from outside window. It comes with compact lens and fiber optic cable. System features through-the-lens laser sighting for precise focus and alignment. It includes full PID control output, and choice of networking options including Ethernet and serial communications.
|
 Environmental Chamber Control adjusts temperature and humdity.Eurotherm Controls
Leesburg, VA 20175
Jun 12, 2002 X26 can store 50 programs with up to 100 steps per program. Program profiles can be set up via controller's front panel using iTools or via Windows setpoint program editor. Real-time clock can be set to start programs at defined times of day and/or week. It has boost heat, boost cool, compressor on/off outputs, program holdback to guarantee soak time at proper temperature and humidity, and 6 sets of PID parameters. Options include Modbus® communications. |