|
|
|
HVAC ->
Heating Equipment ->
Water Heaters
Water Heaters
(Showing headlines 1 - 20) more ....
|
 Water Pump Heater is customizable.Rain For Rent
Bakersfield, CA 93303
Oct 07, 2009
Available from 4-24 in. configurations, Freeze Sentry(TM) water pump heater thaws ice and protects volutes from harsh winter freezing. Portable unit with 12 or 120 V plugs can control equipment temperatures with fast, consistent heat. It can be used to securely cover and heat pump volutes, priming systems, and inlet/outlet areas while at same time maintain open-access to critical valves.
|
 Portable Heater prevents water and liquids from freezing.Rain For Rent
Bakersfield, CA 93303
Sep 11, 2009
Available in various configurations to cover pipe, manifolds, wellheads, pump volutes, barrels, boxes, frac tanks, upright tanks, and water-truck valves, Freeze Sentry(TM) prevents liquids from freezing, while providing clear access to critical valves. Featuring 120 V plugs, product helps to control equipment temperatures with fast, consistent heat.
|
Heat Transfer Appliance suits solar hot water projects.Heliodyne, Inc.
Richmond, CA 94804
Jul 22, 2009
Commercial Solar Station, intended for commercial solar hot water projects, is packaged closed-loop heat transfer appliance that accommodates projects of up to 100 flat plate collectors with single module. Larger projects can combine modules in parallel for limitless sizing potential. Featuring plug and play installation, system includes touchscreen interface, controller for remote Wi-Fi based monitoring and data storage, single/double wall heat exchanger, and integrated VS pumps.
|
 Water Heater combines operational, maintenance efficiency.Lochinvar Corp.
Lebanon, TN 37090
May 01, 2009
Installed with separate storage tank to minimize maintenance concerns, 3 ARMOR® models feature stainless steel heat exchanger, 5:1 modulating turndown, and SMART SYSTEM(TM) operating control. These 98% thermally efficient units, available with inputs from 600,000-800,000 BTU/hr, help eliminate wasted fuel and minimize operating expenditure. Protected against harmful effects of lime scale buildup, products permit direct-vent distances up to 100 ft for combustion air and vent runs.
|
Heat Exchangers are available with copper brazed plate.Diversified Heat Transfer, Inc.
Ridgewood, NY 11385
Feb 26, 2009
Offered in sizes to meet various dimensioning and installation requirements, brazed plate heat exchangers are available with stainless steel plate packs, with thermal output from 1,700 to 8.5 million BTUs/hr, and copper brazing. Various accessories and internationally accepted connection types are available. Areas of use include radiant heating, snow melt, HVAC, and commercial/domestic hot water applications.
|
Water Heaters help reduce energy costs via reclamation.McQuay International
Minneapolis, MN 55440
Nov 25, 2008
Ranging from 500-3,000 MBh, Templifier(TM) water heaters reduce energy costs by recovering waste heat and making it available for space heating and domestic hot water. They can heat water up to 160°F and employ hermetic scroll compressors, which are designed for quiet operation and use R-134a refrigerant. Open Choices(TM) control feature facilitates integration with building automation system using BACnet®, LonTalk®, or Modbus® open standard protocols.
|
 Indirect Water Heater features energy-efficient design.Lochinvar Corp.
Lebanon, TN 37090
Mar 27, 2008
Available in 5 models and sizes, Squire Indirect Water Heater eliminates need for additional gas line, electrical connections, and vent ducts required with direct-fired, tank-type water heaters. Unit features 304 SS heat exchanger coil, 2 in. thick insulation, and plastic jacket that provide rustproof finish, even in wet and corrosive environments. When used with high-efficiency condensing boiler, Squire uses energy generated to heat home to also heat domestic water.
|
 Chiller offers energy-efficient water cooling and heating.Aqua Products Co., Inc.
Newberry, SC 29108
Jan 04, 2008
Utilizing York® air source heat pump and R-410A refrigerant, Model RCS GREEN Reverse Cycle Chiller(TM) (RCC) can heat water to 115°F and cool water to 40°F. System can be sized to heating requirements of home. Available in 2-3 ton and 4-5 ton capacity models, chiller has optional APCHPL16 Aqua Solar Heat Pipe hot water collectors, which feature 16 glass vacuum tubes with high-intensity film and heat pipe to absorb solar energy.
|
 Wall-mounted heating boiler is Energy Star qualified.Lochinvar Corp.
Lebanon, TN 37090
Aug 16, 2007
KNIGHT wall-mounted fully modulating condensing heating boiler features 5:1 turndown burner and adjusts heat output according to demand. Boiler offers an efficiency rating of at least 93%, and permits intake with venting running up to 40 feet using 2 in. pipe. Also features Smart System operating control with user-friendly interface, outdoor reset with sensor, three pump control, night setback, and password security. Optional software enables recording, tracking, and data analyzation.
|
 Indirect Water Heater shares heat with hydronic boiler.Lochinvar Corp.
Lebanon, TN 37090
May 24, 2007
Energy Saver Indirect Water Heater(TM) accepts heat from external heat source that warms space heating fluid, which then passes through unit's internal heat exchanger. As fluid passes through glass-coated, conductive tube, heat is shared between space heating fluid and domestic water in storage vessel. This results in 2 supplies of hot water from one boiler. Non-CFC foam insulation maximizes heat retention, while glass-lined steel tank provides clean hot water.
|
 Water Heater offers thermal efficiencies up to 98%.Lochinvar Corp.
Lebanon, TN 37090
Mar 13, 2007
Available in 5 commercial models with inputs from 150,000-500,000 BTU/hr, ARMOR Water Heater is designed to be installed with separate storage tank for protection against harmful effects of lime scale buildup. Along with stainless steel heat exchanger, product is equipped with fully modulating 5:1 turndown burner and SMART SYSTEM(TM) control with built-in cascading sequencer. Water heater can be vented using PVC or CPVC pipe and permits direct-vent distances up to 100 ft.
|
 Boilers and Water Heaters operate on natural gas or propane.AERCO International, Inc.
Northvale, NJ 07647
Jan 23, 2007
KC1000 high-efficiency boilers and water heaters support sealed combustion in all climates and can be configured to support dual fuel applications. Using natural gas, 78 x 22 x 57 in. units maintain low NOx emissions over entire 11:1 operating range, and can be used in single unit or modular arrangements. One million BTU/hr condensing units feature control software that integrates with BAS/EMS systems and can be accessed remotely.
|
Water Heaters work with any hydronic heat source.Diversified Heat Transfer, Inc.
Ridgewood, NY 11385
Jan 12, 2007
Available in 4 models with 40, 55, 79, and 119 gal capacities, Techtanium Indirect Water Heaters are supplied with 2 magnesium anti-corrosion anodes, exterior steel jacket with powder coat paint, polyurethane foam insulation, and carbon steel tank with oven-glazed titanium glass liner. Units save energy by providing hot water with minimal heat loss.
|
On-Demand Water Heaters promote concrete production.Heatec, Inc.
Chattanooga, TN 37407
Jan 03, 2007
Designed for ready-mix concrete plants, FIRESTORM(TM) raises temperature of water used to make concrete up to 180°F at flow rates from 20-300 gpm. It uses fully modulating, fired burner and exhibits thermal efficiency up to 99%. Controls are automated using PLC technology, and parts subject to corrosion are made from stainless steel. Offered in various sizes, heaters enable ready-mix plants to extend their working season.
|
 Boilers and Heaters have integrated sequencer.Lochinvar Corp.
Lebanon, TN 37090
Dec 15, 2006
With BTU inputs from 1.5-2 million, Power-Fin 1500, 1700, and 2000 models feature internal cascading sequencer for creating lead/lag system in which lead boiler or water heater controls rotating operation and firing rate of up to 7 additional units. They include 2-line, 16-character LCD, 0-10 Vdc BMS input, and 3-pump control capability. With 5:1 turndown modulating performance, systems can fire from 100% down to 20% of rated input to match demand.
|
 Heat Recovery Unit provides free hot water.Turbotec Products, Inc., Div. of Thermodynetics
Windsor, CT 06095
Dec 12, 2006
Engineered to minimize water heating equipment load, Enviro-Pak hot water maker and heat recovery unit uses excess refrigeration energy of existing or newly installed air-conditioning or refrigeration systems in 1.5-5 ton range. Unit can be used with R-22 or R410a applications, and can provide increase in SEER for older systems up to 3 SEER points. Offered with white powder coat paint or stainless steel jacket, system includes indicator lights for operational and safety diagnostics.
|
 Gas Fired Condensing Boiler is IBR-rated.RBI Water Heaters
Westfield, MA 01085
Nov 07, 2006
With full modulation and 3:1 turndown, Futera Fusion(TM) boiler meets changing demands of environmentally sensitive or green building design. Boiler features solid bronze headers, gasket-less heat exchanger, finned copper or cupronickel tubing, and metal-fiber burner. System automatically adjusts energy input to match heating load without over-firing or wasting fuel. Boiler is 29 in. wide and available in sizes from 500-2,000 MBH.
|
 Water Heater uses plate type heat exchanger.Cemline
Cheswick, PA 15024
Mar 29, 2006
Vertically packaged SPH Series water heaters provide solution for producing domestic hot water with hydronic boilers including cast iron, copper tube, water tube, or specialty high efficiency condensing boilers. Completely packaged and ready for use, heater is available in range of storage tank volumes from 60-500 gal with ability to heat up to 2,500,000 BTU/hr of hot water.
|
Steam Heater provides instant hot water.Hydro-Thermal Corp.
Waukesha, WI 53188
Aug 09, 2005 Usable in any process where instantaneous hot water is required, EZ Heater features 100% energy efficient design that eliminates plugging and fouling issues experienced with heat exchanges. Direct steam injection heater, customized to meet exact requirements, accommodates flow ranges to 600 gpm, can reach temperatures to 350°F, and provides ability to produce up to 250° temperature rise. Self-cleaning functions minimize maintenance issues. |
 Infrared Water Heater eliminates fluid contamination.Heraeus Noblelight Inc.
Duluth, GA 30096
May 26, 2005 Ultrapure Water Heater consists of quartz glass twin-tube IR emitter enclosed by larger quartz glass tube with internal gold coating. Offering heating efficiencies exceeding 95%, halogen-free unit can be fit in-line and achieves temperature rises to 80°K depending on liquid throughput and emitter arrangement. Power rating is 6.3 kW for heated length of 600 mm, but heated lengths up to 2 m are possible. Max emission is rated from 900–1,400 nm. |
(Showing headlines 1 - 20) more ....
|
Latest Products in the News |
American Power Service - October 27, 2009 The New Paradigm: Rebuilding Aging Feedwater Heaters, On-Line, with Minimal Downtime
More Products in the News...
|
|
|
|
 |
ThomasNet News Advertisers
|
 |
|