Heat Pumps

Green & Clean, Fluid & Gas Flow Equipment, HVAC

Water Source Heat Pumps offer economizer option.

July 29, 2015

Available on 2–6 ton horizontal and vertical Versatec Base, Versatec Ultra Envision2 Compact, and 7-25 ton horizontal and vertical Envision XL products, Waterside Economizer option allows use of building’s interior loop water to provide free cooling. Economizer works by passing air through internal coil cooled by loop water rather than by mechanical refrigeration. Unit contains water-to-air heat exchanger, 3-way valve, and controls that manage flow of water through heat exchanger. Read More

HVAC, Green & Clean

HVAC Systems target light commercial applications.

June 11, 2015

Consisting of packaged heating and cooling units, packaged heat pumps, and split systems, TempMaster® Product Line offers variety of tonnages, fuel sources, configurations, and heating/cooling varieties. Products are rigorously tested and rated in accordance with AHRI Standard 210/240 and 340/360 and meet relevant ASHRAE 90.1, ENERGY STAR, and EPACT 2005 standards. Read More

Fluid & Gas Flow Equipment, HVAC, Green & Clean

Hydronic Geothermal Heat Pump uses vapor injection technology.

April 8, 2015

Offering efficiencies up to 16.1 EER and 3.3 COP, 5 Series 504W11 Energy Star®-rated water to water heat pump operates in heating-only or heating/cooling mode and leverages OptiHeat vapor injection technology. Latter creates exiting water temperatures up to 150°F using additional heat exchanger that diverts excess heat and reinjects it into system. Additional system components include Copeland scroll compressors, R410-A refrigerant, and Aurora communicating controls platform. Read More

HVAC, Fluid & Gas Flow Equipment

Dishwasher Heater Pump enhances cleaning, sanitization.

March 16, 2015

With integrated heating and circulation function, Super Series is driven by brushless motor technology and delivers performance needed for cleaning and sanitizing. It enables washing temperatures up to 185°F, which kills germs while reducing washing and drying time. Promoting safety and reliability, heating elements are designed to prevent accidental contact by users or with dishwasher contents. Hydraulic and heater design maximizes operational efficacy for water heating and circulation. Read More

HVAC

Heat Pump Water Heater cuts facility's carbon footprint.

February 24, 2015

Consisting of 2 pieces of equipment, Ilios™ HEWH-500-AS Split System combines engine-driven heat pump portion, which is contained in small acoustic enclosure within building mechanical space, and remote air-source evaporator package, which can be placed outside mechanical room. Since remote evaporator has minimal service needs, it can be placed in difficult-to-access areas. Tightly packaged in 3 x 5 ft enclosure, indoor component easily retrofits into existing mechanical spaces. Read More

HVAC

Cold Climate Heat Pumps support multiple zones.

November 24, 2014

Available in capacities from 22–54 K Btu/h, Hyper-Heating INVERTER™ MXZ Units are suited for residential heating and cooling in extreme conditions. Outdoor systems feature 100% heating capacity at 5°F and guaranteed operation down to -13°F. Single multi-zone unit is capable of connecting to up to 8 indoor units. H2i MXZ units are compatible with Mitsubishi Electric’s ductless and ducted indoor air handlers, including H2i MSZ-FH, which features 3D heat imaging technology. Read More

HVAC

Portable Heat Pump combines heating and cooling.

October 13, 2014

Combining both cooling and heating capabilities in single, self-contained unit, Climate Pro™ 18 offers cooling capacity of 14,600 Btu/h, heating capacity of 13,700 Btu/h, and minimum operating temperature with plenum of 24°F. Controller features large LCD that displays diagnostics and step-by-step instructions to start, set up, or restore operation. To ensure long-term reliability, systems are designed with hermetically sealed refrigeration units and fan motors. Read More

HVAC, Fluid & Gas Flow Equipment

Geothermal Heat Pump utilizes ozone-safe R410A refrigerant.

October 13, 2014

Featuring Copeland UltraTech™ 2-stage scroll compressors and 5-speed ECM blowers, 3 Series 300A11 offers efficiencies up to 22.3 EER and 4.1 COP. Residential unit comes standard with all-aluminum air coils for corrosion protection and extended system life. When used with IntelliZone2 24 V zoning system, 3 Series can precisely control temperature in up to 4 zones. Aurora communicating controls platform provides setup, troubleshooting, and diagnostics. Read More

HVAC, Green & Clean

Residential Geothermal Heat Pump is offered as split system.

July 17, 2014

Offering up to 33.0 EER (part load) and up to 24.0 EER (full load) GWHP, Greensource CDi Series SM Model is available in split system that lets installer separate condenser section up to 75 ft away from fan coil section to isolate sound (as low as 52 dB), vibration, and unwanted heat from conditioned space. Condenser may be located indoors or outdoors. Also included, Bosch communicating thermostat displays alerts and controls air temperature as well as humidity levels. Read More

HVAC

HVAC System features high-efficiency design.

March 21, 2014

Combining 2-stage compressor, variable frequency drive, and indoor/outdoor coil and motor, Luxaire® Ovation™ Ultra High Efficiency Packaged Unit delivers AHRI-listed efficiencies up to 18.1 SEER and 14.35 EER. Unit is available in cooling and electric/gas heat configurations, features slide-out blower and motor for servicing, and is ASHRAE 90.1 & 189.1 (2010) compliant with IntelliSpeed (2-speed) option and IntelliComfort II controls standard. System installs on curb, slab, roof rack, or frame. Read More

HVAC

Heat Pump System is optimized for total life cycle expense.

March 6, 2014

As one integrated system, modular VRV IV promotes energy efficiency, individual user control, and reliability. Variable refrigerant temperature auto climate adjustment technology allows continuous adjustment of VRV IV refrigerant temperature, while larger capacity single modules and systems allow for flexible design. VRV IV configurator software package, included, allows remote configuration of operational settings that can then be used at several installation sites. Read More

HVAC, Fluid & Gas Flow Equipment, Thermal & Heating Equipment, Materials & Material Processing

Miniature Thermoelectric Modules offer optimal heat dissipation.

February 5, 2014

Built using Tlam thermally conductive circuit boards, Tlam OptoTEC® series is designed for applications where temperature stabilization of sensitive optical components is critical. Circuit boards have thin layer of thermally conductive dielectric material between copper foil layer and metal backing plate. Comprising 7 modules, series can create temperature differential (ΔT) of up to 67°C and pump from 1.5–9.0 W of heat at 25°C. At 85°C, series can create ΔT of 77°C and pump 1.6–9.9 W of heat. Read More

HVAC

High Efficiency Water Heater uses both water and air sources.

January 23, 2014

Using low-grade waste heat as well as geothermal/groundwater as free energy source, Ilios Model HEWH-500-WS offers both hot water and chilled water simultaneously. Unit is designed to fit through standard doorways and is also rated for outdoor installation in places where mechanical space is limited. Heater is equipped with acoustic enclosure to ensure quiet operation, and system qualifies for 10% ITC under mechanical CHP category. Read More

HVAC, Fluid & Gas Flow Equipment

Air Conditioners, Heat Pumps offer ductless delivery.

September 18, 2013

Available for residences and commercial buildings, Luxaire® mini-split air conditioners and heat pumps enable delivery of heating and cooling to structures without ductwork. Systems combine outdoor units and wall-mounted indoor units linked by conduit that requires 3–4 in. opening. Supplied with wireless remote controller with built-in temperature sensor, single- and multi-zone models offer modulating compressor technology, cold blow prevention feature, and multi-part filter system accessory. Read More

HVAC, Green & Clean

Heat Pump System helps optimize vehicle efficiency.

October 3, 2012

Utilizing ambient air and ancillary heat, Heat Pump System optimizes cabin conditioning for hybrid and electric vehicles. System's electric compressor cools cabin by operating refrigerant cycle in one direction and heats cabin by operating cycle in reverse direction. By minimizing power drawn from lithium-ion battery, vehicles equipped with heat pump system can operate longer on single charge. Read More

HVAC, Mechanical Power Transmission, Green & Clean

Steam Turbine for geothermal power plants.

November 8, 2011

Rated up to 60 MW, SST-400 GEO combines SST-400 steam turbine gearbox, generator, and base frame with TurboCare steam path technologies. Corrosion-resistant materials prevent fatigue-related crack formation and fractures, and design is suitable for live steam temperatures up to 250°C and steam pressures to 12 bar absolute. Able to be deployed in plants with different thermal fluids, turbine can be used in plants that operate with dry steam, flash principle, or flash/binary combined cycle. Read More

HVAC, Fluid & Gas Flow Equipment

Double Suction Case Pumps come in 1,160 and 1,760 rpm.

July 17, 2009

Available in bronze fitted and all iron versions, TC Series have standard operating temperature at 250ºF and 175 psig in accordance with ANSI Standard B16.1. Mechanical seal has tungsten carbide rotating element and stationary seat, and carbon steel or stainless steel shafts come with replaceable bronze or stainless steel sleeves. Suitable applications include in heating, air conditioning, pressure boosting, cooling water transfer and water supply. Read More

HVAC

Heat Pump suits northern climates.

March 23, 2004

Cold Climate Heat Pump(TM) provides continuous heating down to and below 0°. It uses multiple stages of heating through Bristol® TS Compressor, booster compressor, and economizer. These components, along with Johnson Metasys Control, respond to indoor and outdoor air conditions for both heating and cooling seasons. Coefficient of performance is 2.7 at 17°F and 2.0 at 0°F. Available in 2.5, 3.5, 4.0, and 5.0 ton models, pump uses EPA-approved R-410A refrigerant. Read More

HVAC, Fluid & Gas Flow Equipment

Heat Pump Water Heater offer simplified installation.

December 18, 2003

Available for new or existing home water heaters, environmentally sound E-Tech R106K-5 extracts low grade heat from ambient air, upgrades it, then transfers it as energy to heat water up to 130°F. Air passing through unit is cooled and dehumidified and can be used for cooling basements, garages, and workshops. Water heater-mounted units require indoor location with 1,000 ft³ min space, adequate ventilation, and temperature range of 46 to 110°F. Read More

HVAC, Fluid & Gas Flow Equipment

Heat pump has 10 SEER cooling efficiency.

February 6, 2003

SH10B heat pump offers 2-5 ton cooling capacity and up to 7.00 HSPF. Copeland Compliant scroll compressor has insulated cabinet for sound control and vertical air discharge. Unit has evaporator coil with anti-microbial coating, permanently lubricated motors, and galvanized steel base rails. All models feature adjustable time and temperature defrost controls and 4- and 5-ton models are convertible to downshot for rooftop applications. Read More