Hot Water Boiler produces low NOx levels.Parker Boiler Co.
Los Angeles, CA 90040
Dec 22, 2003 Direct-fired Parker T-6800LR Ultra Low NOx Hot Water Boiler is available in sizes to 6,300,000 BTU Input with bent tube all welded design. Integral finned tube convective section (R Unit) raises efficiencies up to 85%, while NOx levels below 12 ppm at 3% O2 and CO levels below 100 ppm meet SCAQMD Requirements. LR model has metal fiber burner system that offers even distribution of heat over entire tube bundle area. |
 Heat Pump Water Heater offer simplified installation.Applied Energy Recovery Systems
Norcross, GA 30067
Dec 18, 2003 Available for new or existing home water heaters, environmentally sound E-Tech R106K-5 extracts low grade heat from ambient air, upgrades it, then transfers it as energy to heat water up to 130°F. Air passing through unit is cooled and dehumidified and can be used for cooling basements, garages, and workshops. Water heater-mounted units require indoor location with 1,000 ft³ min space, adequate ventilation, and temperature range of 46 to 110°F. |
 Scotch Boiler is available in sizes up to 800 hp.Burnham Corp.
Lancaster, PA 17604
Nov 26, 2003 Series 4S Four-Pass Wetback Scotch Boiler, for high- and low-pressure steam or hot water, incorporates positive water flow circulation and maximum heat transfer from water-backed surfaces. Rear access door incorporates lightweight, vacuum-formed insulation and eliminates need for hinges and heavy davits. Boiler uses no proprietary parts or gaskets on boiler trim or burner, ensuring availability of replacement parts. |
 Water Heater eliminates need for storage tank.Leslie Controls, Inc.
Tampa, FL 33637
Oct 28, 2003 Safety Shower Water Heater System provides required volume of precisely heated water in any ambient condition, without heated storage tanks. Skid-packaged unit utilizes Constantemp Feedforward Steam Hot Water Heater that is accurate to ±3°F. Continuous recirculation maintains water temperature and prevents lines from freezing. Capacities to 120 gpm are available. |
 Steam Boilers produce dry steam.Miura Boiler West, Inc.
Wheeling, IL 60090
Oct 13, 2003 EX gas/oil series high-pressure steam boilers produce dry, 99+% saturated, steam through 3-stage process. Process includes initial separation in vertical water tubes, second separation in upper header and baffle plate, and final separation in cyclone separator. Design minimizes carryover, while low water content water-tubes accelerate steam production (5 min from cold start). |
 Indirect Fired Water Heater is available in four sizes.Burnham Corp.
Lancaster, PA 17604
Aug 26, 2003 Porcelain (glass) lined Alliance G combines longevity and corrosion-resistance of porcelain enameled tank and coil with heat recovery of indirect fired water heater. Each tank is surrounded by CFC-free foam insulation and includes aquastat, clean out inspection plate, and sacrificial anode rod. Product is wrapped in steel jacket (40 and 50 gal sizes) or plastic jacket (79 and 100 gal sizes). |
 Energy System is rated up to 356 kW.DTE Energy Technologies, Inc.
Detroit, MI 48226
Jul 29, 2003 Model ENI 415 is a combined heat and power, on-site energy system with pre-engineered packaged design for indoor or outdoor installations. It can support peak and full load requirements, providing full power in event of utility outages. System is suited for base load and waste heat utilization applications. Waste heat applications can provide both chilled and hot water, enabling commercial and industrial customers to offset natural gas and electricity consumption. |
Energy System meets stringent emissions requirements.DTE Energy Technologies, Inc.
Detroit, MI 48226
Jul 29, 2003 Model ENE 210 combined heat and power, on-site energy system features cooled exhaust, gas recirculation engine technology. Pre-engineered packaged design can be installed indoors or outdoors. System is suited for base load power applications. Additional system efficiency can be gained by utilizing system’s waste heat. Waste heat applications can provide hot water, enabling commercial and industrial customers to offset natural gas and electricity consumption. |
 Electric Unit Heater ranges in size from 3-10 kW.INDEECO
St. Louis, MO 63144
Jul 18, 2003 Series UHI comes with built-in controls and can be wall or ceiling mounted. Standard voltages include 208, 240, 277, and 480 in single and 3-phase. Cabinets are heavy gauge galvanized steel and tubular elements are 304 SS. Individually adjustable louvers direct airflow where needed. Single point, line voltage connection enables heater, fan, and controls to be connected to same branch circuit. Built-in, automatic reset thermal cutout provides overtemperature protection. |
 Air Heating Burner handles temperatures to 2,500°F.Eclipse, Inc.
Rockford, IL 61103 1299
Jul 03, 2003 RatioAir velocity burner has integral packaged blower that is available in 4 different models with capacities from 1–5 mm BTU/hr. Ratio regulator automatically compensates for changes in operating conditions and ensures ratio-controlled operation over turndown range of more than 50:1. Direct drive air butterfly eliminates linkages, and burner achieves gas velocities of up to 500 ft/sec. It suits applications that require use of unusual fuels and confined firing chambers. |
 Water Heater inhibits ignition of flammable vapors.Lochinvar Corp.
Nashville, TN 37210 3807
May 13, 2003 Residential water heater, with Shield Combustion System™, employs Lock-Shield flame arrestor plate with 18,000 air louvers that prevent ignited flammable vapors from traveling backwards out of combustion chamber/water heater. Thermal switch detects increases in heat and shuts down gas supply to pilot and main burner. Piezo igniter provides pushbutton ignition of pilot flame, while sight glass allows unrestricted view into combustion chamber for observation of burner and pilot flames. |
 Water Heater has double-wall heat exchanger.Leslie Controls, Inc.
Tampa, FL 33637
May 01, 2003 Constantemp heater provides instantaneous hot water at desired temperature. Heat exchanger consists of tube within tube, with air space in between to prevent contamination of potable water by toxic heating substance. Feed-forward blending device ensures hot- and cold-water blend ratio is accurately proportioned to maintain set temperature for flow demands up to 7,200 gph. Integrated fail-safe system prevents overheating/scalding. |
 Water Heater Module mounts to wall.FlatPlate, Inc.
York, PA 17404
Mar 27, 2003 DHW Green Hot Water Heater Module, for domestic hot water heating, eliminates cold showers when connected to hydronic boilers. Capacity range is 75,000–400,000 Btu/hr, with up to 1,000,000 Btu/hr available when full boiler hot water heating and fast recovery are required. System module includes heat exchanger, pumps, hand and balancing valves, temperature gauges, control interface and electrical connections. |
Water Heaters feature dual O-ring system.AMTROL Inc.
West Warwick, RI 02893
Mar 27, 2003 BoilerMate™ Series tanks have seamless inner corrosion-proof, nonmetallic, polyethylene reservoirs, and CFC-free molded insulation. Dual O-Ring Sealing System for WH-7 and WH-9 Series water heaters provides second seal that protects interior section of water heaters. Dual O-ring offers confirmation of seal and guards against future leaks. If seal is not secure, second O-ring inhibits internal water heater damage caused by internal leaks. |
Water Heaters have dual O-ring sealing system.AMTROL Inc.
West Warwick, RI 02893
Mar 06, 2003 Indirect-fired Series WH-7 and WH-9 BoilerMate™ Classic incorporate sealing system which provides second seal that acts as backup for protection of interior section of water heaters. Sealing system disperses water that leaks down exterior sides of water heater if seal is not secure and inhibits internal water heater damage caused by internal leaks. Products use seamless inner corrosion-proof, nonmetallic, polyethylene reservoirs and CFC-free molded insulation. |
Gas Water Heater/Boiler provides installation flexibility.Lochinvar Corp.
Nashville, TN 37210 3807
Feb 11, 2003 Commercial Copper-Fin II provides 990,000–2,070,000 Btu/hr and 85% (water heater) and 84% (boiler) efficiency. Unit incorporates independent dual-ignition systems, gasketless heat exchanger, and multiple referenced gas valves. Multiple blowers maintain proper airflow, while built-in sequencer automatically controls each function. With 7 venting options, multi-stack frame unit has fan-assisted combustion process, which produces NOx emissions at rates of less than 30 ppm. |
Gas Water Heater can be used in negative air conditions.Lochinvar Corp.
Nashville, TN 37210 3807
Feb 11, 2003 With fully condensing, sealed combustion chamber, tank type TurboCharger™ is suited for tight mechanical rooms. Unit offers direct vent design, which draws all combustion air from outside and vents all byproducts outdoors. Submerged combustion chamber, premix power burner, and triple pass flue system create thermal efficiencies to 98%. Single model configuration is offered with storage capacity of 100 gal and firing rate of 200,000 Btu/hr in natural gas. |
 Heat pump has 10 SEER cooling efficiency.Excel Comfort Systems, Inc.
Blackville, SC 29817
Feb 06, 2003 SH10B heat pump offers 2–5 ton cooling capacity and up to 7.00 HSPF. Copeland Compliant scroll compressor has insulated cabinet for sound control and vertical air discharge. Unit has evaporator coil with anti-microbial coating, permanently lubricated motors, and galvanized steel base rails. All models feature adjustable time and temperature defrost controls and 4- and 5-ton models are convertible to downshot for rooftop applications. |
 Hot Water Tanks add storage to existing water heaters.AMTROL Inc.
West Warwick, RI 02893
Jan 08, 2003 StorageMate™ insulated tanks are offered in 41, 80, and 119 gallon models. Smallest model utilizes dense, polyethylene liner, while larger models are constructed of stainless steel. Tanks can function as recirculating aquaboosters with tank-less coils, hydronic buffer tanks for low-mass boilers and radiant systems, and as additional storage. Optional mechanical aquastats control temperature. Applications include whirlpool baths, hot tubs, dishwashers, and laundry machines. |
 Heating System provides space heating for warehouses.Greenheck Fan Corp.
Schofield, WI 54476 0410
Oct 29, 2002 GreenHeat System uses direct gas-fired burner designed and ETL listed for 140°F temperature rise. It includes discharge diffuser to evenly distribute high temperature air for consistent space heating. Louvers, roof fans and propeller fans are available to complete package. |