 Condensing Boiler features 316L SS fire-tube technology.Lochinvar Corp.
Lebanon, TN 37090
Feb 08, 2011
Available in 5 models ranging from 1.5-3.5 million Btu/hr with thermal efficiencies up to 99%, CREST® Condensing Boiler features low-NOx combustion system with stainless steel heat exchanger and dual-system burner with up to 25:1 turndown. Top-mounted, single micro-metal fiber burner serves as 2 combustion systems in one, each with its own blower and gas valve assembly. Operating at flow rates from 20-350 gpm, boiler includes SMART TOUCH user control with 8 in. multi-color touchscreen display.
|
 Hybrid Ventilation Unit incorporates energy recovery capability.Thomas & Betts Corp.
Memphis, TN 38125
Dec 21, 2010
Designed to help meet standards of acceptable levels of indoor air quality (IAQ), Z Series integrates energy recovery wheel into dedicated heat pump system for ventilation and temperature control. Unit can recover more than 80% of exhaust air energy year-round, and energy efficiency ratio (EER) is greater than 17 in cooling mode. In heating mode, coefficient of performance is greater than 10.
|
 Wall-Mount Boiler has optimized fire tube design.Lochinvar Corp.
Lebanon, TN 37090
Nov 26, 2010
Available in 7 models with 55,000-399,000 Btu/hr inputs, KNIGHT® boiler features welded, stainless steel heat exchanger that uses ovular tubes with dimpled design that slows flue products and extracts available latent energy. SMART SYSTEM(TM) control has cascading sequencer that allows installation of up to 8 units for 3.2 million Btu/hr max capacity. Along with fully modulating 5:1 turndown burner, features include water backed combustion chamber that provides thermal efficiencies up to 99%.
|
 Hybrid Ventilation Unit provides year-round performance.Reznor V3?
Memphis, TN 38125
Nov 16, 2010
Compliant with design goals of LEED and ASHRAE standards (90.1 and 62.1), Z Series combines heat pump and energy recovery wheel into one tested and verified, plug-and-play, commercial ventilation unit. When the outdoor air temperatures are between -10 and +45°F, unit modulates DX heat pump system and total enthalpy wheel to provide 70°F heated air to space. During warmer months, unit delivers dehumidified, 70°F fresh air to building with EER exceeding 17.0.
|
Scotch Marine Boilers feature 2-pass design.Hurst Boiler & Welding Co., Inc.
Coolidge, GA 31738
Sep 16, 2010
Available in steam or hot water versions with 15-800 hp ratings and pressures to 300 psig, Series 250 features 2-pass design that eliminates refractory baffles between flue gas passes. Units have front-mounted smoke box with slip-on stack connector and large combustion chamber with low heat release for complete combustion. Built in accordance with ASME Codes, boilers are insulated with 2 in. high-density mineral wool, lagged with 22 gauge grip jacketing, and have baked on epoxy enamel.
|
 Commercial Pool Heater incorporates smart control system.Lochinvar Corp.
Lebanon, TN 37090
Aug 16, 2010
Offering efficiency of up to 97%, inputs up to 800,000 Btu/hr, and fully modulating 5:1 turndown, XLP Commercial Pool Heater consists of stainless steel heat source piped to Cupro-Nickel heat exchanger, which is salt water approved and features shell and tube design that heats pool water indirectly, completely isolating water from combustion process. SMART SYSTEM(TM) user interface provides access to all information needed to set-up, troubleshoot, and monitor all equipment functions.
|
 Flexible Water Tube Boilers offer thermal efficiency of 90%.Bryan Steam LLC
Peru, IN 46970
Jun 30, 2010
Triple-Flex(TM) ultra-high efficiency condensing flexible water tube boiler models, TF 150, TF 200, and TF 250 offer inputs from 1,500-2,500 MBH with sub 30 ppm NOx utilizing hybrid metal fiber burner. Other features include replaceable stainless steel flexible tubes, variable speed combustion air blower, and easy to remove access panels for service and inspection of boiler interior.
|
 Direct Steam Injection Water Heaters are custom-engineered for operating conditions.Kadant Johnson, Inc.
Three Rivers, MI 49093
Jun 10, 2010
Nominally available in 1.5-6 in. sizes, direct steam injection water heaters raise temperature of water and water-based slurries by injecting steam directly into fluid. They accommodate various industrial processing applications and are custom-engineered based on operating conditions to ensure optimal performance and efficiency. Absence of moving parts, with exception of actuator and modulating spindle, promotes reliability and service life.
|
 Indirect-Fired Gas Heater achieves efficiencies of over 90%.Munters Corporation - Dehumidification Division
Amesbury, MA 01913
May 10, 2010
Suited for spray dryers and industrial processes with high temperature rises, VariMax(TM) IFRG heats process air streams without contaminating air with products of combustion. Standard features include stainless steel heat exchanger, FM or IRI certified gas trains, and complete heater controls. Ultra-high efficiency heater is custom designed for each application with 1,000°F max temperature rises and exit temperatures up to 1,200°F.
|
Solar PV Encapsulant Sheet maximizes reflectivity.DuPont
Research Triangle Park, NC 27709-4425
May 04, 2010
DuPont(TM) PV5223 is white reflective encapsulant that is placed on backside of Oerlikon Solar's thin film coatings. It reflects sunlight back through module's active layer, allowing for 94% reflectivity of module. Measuring 0.45 mm thick, sheet offers optimal durability and, by eliminating need for reflective paint, simplifies manufacturing process.
|
Cabin Heater promotes electric vehicle safety and comfort.BorgWarner
Auburn Hills, MI 48326
Feb 19, 2010
Installed in air conditioning system and connected to vehicle's 400 V electrical system, cabin heaters achieve 3,000 W output to effectively defrost windshields and provide warm, comfortable driving environment for drivers and passengers. Each is designed with high-voltage connection as well as ceramic components and can be modified for all-electric and hybrid vehicles with various electrical system voltages.
|
 Electric Steam Boiler incorporates safety features.SUSSMAN Electric Boilers, a Div. of Sussman-Automatic Corp.
Long Island City, NY 11101
Feb 16, 2010
Stainless steel SSB model features float-type low water cut-off control that automatically maintains proper water level for safe operation and shuts off boiler when water supply falls below safe level. Industrial-grade, heavy-duty 0.420 in. dia stainless steel sheathed heating elements with one piece resistance welded terminations provide extended operating life and security. Other features include water level sight glass, main on-off switch, and steam stop-valve.
|
 Steam Heaters protect field instrumentation.INTERTEC Instrumentation Ltd
Sarnia, ON N7T 7H5
Feb 05, 2010
Offering choice of vertical, horizontal, or panel mount styles, STEAM series is available with 4 power outputs from 65-490 W and suits enclosure-scale freeze/condensation protection or temperature maintenance applications. Products are developed from anodized aluminum, finned convection heater profiles and suited for use in refineries and other plants. Steam heating elements come with press-fitted 12 mm OD stainless steel tube for connection to steam/hot water service line.
|
 Condensing Water Heaters have high-efficiency design.Armstrong International, Inc.
Three Rivers, MI 49093
Jan 15, 2010
Optimized for precise temperature control, Flo-Eco(TM) storage type water heaters deliver 95% efficiency in most operational modes and suit all types of building environments.
Unit incorporates Brain® digital re-circulating valve, and optional hot water management system console can be linked with BacNet, LonWorks, ModBus, and can be Web enabled. Tuff-Tank replaceable tank liner is rated for continuous use at temperatures to 185°F. Compact design can be moved through a 28 x 80 in. doorway.
|
Electric Heaters handle nitrogen and DI water.Infinity
Worcester, MA 01604
Jan 15, 2010
Available up to 16 kW with process temperatures to 600°C, Compact Resistive Element Heaters Generation 2 replace bulky conventional electric heaters in semiconductor, pharmaceutical, and food industries. Units are available with or without factory turnkey control package, and are designed to withstand no-flow or non-submerged operation for short periods of time without burning out.
|
 Gas-Fired Boilers operate with 85% efficiency.Bryan Steam LLC
Peru, IN 46970
Dec 16, 2009
Available in 6 models with inputs from 900-3,000 mbh, forced draft HE-AB Series features 7 ft² of heating surface per boiler horsepower and operates at normal temperatures without special venting/condensing material. Combustion efficiency results from integrated extended surface heat extractor, while flexibility of bent water tube design eliminates all possible damage from thermal shock and stresses caused by poor or unequal internal circulation.
|
Packaged Water Heaters use plate type heat exchanger.Cemline
Cheswick, PA 15024
Dec 11, 2009
Suited for use in many hydronic heating style applications including systems using low temperature boiler water, BPH/PFH heaters have ability to heat up to 5,000,000 Btu/hr of hot water. Plate type heat exchanger allows for maximum heat transfer between boiler water and domestic water. Heaters come completely packaged, ready for use and require only connection to services. BPH heater uses brazed plate heat exchanger, while PFH uses plate and frame style heat exchanger.
|
Solar Water Heaters come factory-packaged and ready for use.Cemline
Cheswick, PA 15024
Dec 11, 2009
Designed for operating using either energy from external solar collector or as dual-energy source unit, Solar Water Heaters use solar controller and double walled brazed plate heat exchanger to maximize heat transfer. Additional heating source, using boiler water, steam, or electricity, can be use in situations where solar energy is lacking or unavailable. They are available in variety of storage tank volumes from 120-680 gal with ability to heat up to 2,500,000 BTU/hr of hot water.
|
Cooling/Heating Systems are offered in indoor and outdoor models.Mitsubishi Electric Automation, Div.
Vernon Hills, IL 60061
Oct 28, 2009
Suited for single- or multi-zone applications, MSY/Z-GA indoor models of split-ductless M-Series STAR LINEUP, on MSZ models, provide energy efficiency up to 17.5 SEER and 9.5 HSPF. Model MSZ-GA24NA is compatible with MXZ-A outdoor unit to meet multi-zone requirements. Systems offer rated BTU/hr of 24,000 and wide vane operation for optimal air delivery. Featuring compressor with permanent rare-earth magnet, they are available in cooling-only and heat pump models.
|
 Air Conditioners/Heat Pumps are offered in various models.Mitsubishi Electric Automation, Div.
Vernon Hills, IL 60061
Oct 27, 2009
Compatibile with MXZ-2B20NA multizone systems, MSY/Z-GE systems, part of split-ductless M-Series STAR LINEUP, feature single-zone cooling-only and heat pump models. Systems include 8 models with rated BTU/hr capacities from 9,000-18,000. ENERGY STAR® rated models are also available. Devices offer efficiencies of up to 20.5 SEER and provide quiet operation as low as 19 dBA.
|