Central Cooling Plants have pre-engineered, modular design.McQuay International
Minneapolis, MN 55440
Aug 07, 2008
Pre-assembled to facilitate installation, modular central plants are suited for new construction and expansion projects where fast-track completion schedules or minimal interruption to cooling are priorities. Solutions combine water-cooled chiller with pumps, cooling tower, and interconnected piping. Chiller models include screw, scroll, centrifugal, or magnetic bearing compressor, depending on requirements, while cooling tower includes VFD as standard. Sizes range from 100-600 tons.
|
Peltier Devices are offered in compact sizes.CUI, Inc.
Beaverton, OR 97005
Jul 31, 2008
Offered in sizes 15 x 15, 20 x 20, and 30 x 30 mm with heights ranging from 3.3-5.1 mm, CPXXXXX Series Peltier Devices have no moving parts and are suited for applications where size and weight are limited. They provide input of 2.0-8.5 A, solder melting point of 138°C, and maximum compress of 98.07 N/cm². Available with heights from 3.8-4 mm, 40 x 40 mm version features input of 6.0-8.5 A.
|
 OEM Thermoelectric Cold Plate has dual butterfly mounts.Elite Thermal Engineering
Bothell, WA 98021
Jul 08, 2008
Featuring 2 model BA-01 butterfly mounts, OCP-050A stabilizes uncooled butterfly lasers using external TECs. It features aluminum cold plate and proprietary thermoelectric modules, which maintain enough cooling capacity for 2 of any high-power pump lasers. Butterfly lasers with internal thermoelectric coolers have lower power due to cooling capacity limit of internal TECs. Uncooled butterfly lasers provide higher power limited only by laser diode itself.
|
 Heating and Cooling Coils offered in choice of materials.Diversified Heat Transfer, Inc.
Ridgewood, NY 11385
Apr 10, 2008
Coils are manufactured from tube materials consisting of copper, 90/10 cupronickel, SS, or carbon steel. Steam Coils have standard steam and steam distributing coils. Also available are industrial HVAC heating and cooling air-handling coils and plate fin, helical fin, L-footed, and solder-bonded air coils with 3/8-1 in. OD tubing for steam and water applications. Econo Line shell and tube heat exchangers, 4-30 in., are offered in steam-to-liquid or liquid-to-liquid styles.
|
 Automatic Fogging Machine features dual timer assembly.Mist Cooling Inc
Richmond, TX 77469
Mar 20, 2008
Suited for industrial, residential, commercial, and hospitality applications, Model FM920 automatic fogging machine features ceramic piston sleeves for creating pressure of 920 psi. Dual timer assembly, with settings for minutes and seconds, allows users to set exact misting and stop times desired. Pump automatically stops when water supply is interrupted, and 0.1 mm mesh inlet filter prevents debris from entering pump.
|
 Tramp Oil Separator features compact design.Master Chemical Corporation
Perrysburg, OH 43552
Mar 12, 2008
Intended for use with water-miscible coolants and parts washing fluids, Master Coalescer Jr.(TM) works with CNC machines with small, hard to access coolant sumps. It includes removable media pack that provides up to 132 square ft of coalescing surface, and comes with electric 120 V diaphragm pump that primes to 48 in. Tramp oil separator is also available in portable model that features 2 rigid and 2 swivel casters and hinged pull handle with magnetic latch.
|
Thermoelectric Coolers have up to 100 W/cm² cooling power.Micropelt GmbH
Freiburg 79110 Germany
Oct 05, 2007
Supporting maximum temperature difference (delta T) of over 60° Kelvin, Series MPC-D303 microchip thermoelectric coolers (TECs) target laser and photonic sensor manufacturers. Fabricated on silicon wafer using standard semiconductor processes and soldered at 300°C, chip-sized TECs feature cold side area of only 0.98 mm². With maximum operating temperature of 200°C, they can realize temperature changes faster than 180° K/sec.
|
Cooling Systems protect workers from heat stress, fatigue.Salisbury Electrical Safety, LLC
Skokie, IL 60077
Sep 04, 2007
Mounted to short and full brim hardhats, PRO-AIR(TM) ACAIR3000(TM) provides forced ambient air throughout headwear to keep workers cool. Microprocessor-controlled unit, powered by rechargeable batteries, offers automatic and manual functions. Also available, ACAIR2000(TM) is designed for arc flash hood applications. It provides continuous air supply to worker while reducing hazardous effects of shield fogging. Rechargeable batteries offer 3 hr of continuous operation per charge.
|
 Temperature Controller works with fluid dispensing systems.Sealant Equipment & Engineering, Inc.
Plymouth, MI 48170-0965
Aug 17, 2007
Peltier series Thermoelectric Temperature Controller combines Peltier thermoelectric device, temperature sensor, and temperature control mounted to manifold where fluid passes through to be heated, maintained, or cooled. Mounted in-line or on fluid dispensing equipment, product uses Peltier-Seebeck effect to directly convert electrical voltage to thermal differentials and heat or cool fluid materials to temperature set point. Accessories are available.
|
Cooling Seat Cushion fits most cars, trucks, and SUVs.Nocord
Richmond, VA 23224
Jan 10, 2007
Utilizing centrifugal fan, SummerSeat pulls in fresh air to cool back and bottom of driver or passenger. Foam cushioning, microfiber mesh, and Eva(TM) Cooling Plastic promotes cool air flow, while adjustable cooling control lets user set desired level of comfort. Product draws minimal power from vehicle's battery and has energy saving automatic shut-off timer that deactivates seat every hour. Optional ac adapter is available for office use.
|
 Chip Conveyor features coolant filtration and separation.Mayfran International
Cleveland, OH 44143-0038
Sep 19, 2006
ConSep single-platform chip conveyor/coolant separator removes chips and contaminates to 50 microns in size. Separator has internal chip handling (auger) system, which also handles fines and sediment, and backwash that automatically cycles to indexing filter drum's poly fiber media, making unit maintenance free. Clear access panel enables visual inspection of cleaning process, and filtered coolant is held in holding tank for return to machine tool.
|
 Coolant System monitors volume and mix ratios.Mayfran International
Cleveland, OH 44143-0038
Sep 19, 2006
Mounted to machine coolant tank, Coolant Control Center (CCC) provides continuous real time in-line monitoring of coolant, measuring coolant concentration, PH, conductivity, temperature, and volume. System features PLC for coolant correction and programming routines for precise maintenance of machining fluids. Measuring 16.92 x 38.89 x 11.92 in., CCC has ¾ in. water inlet union and works with 220 V 2-phase electric connector or 400 V 3-phase power hookup.
|
 Fluid Recovery System can be moved to any location.Kinefac Corporation
Worcester, MA 01603-1260
Sep 18, 2006
Maneuverable in factory aisles, compact system removes solid contaminants from coolant and lubricant fluids used in metalworking processes. It utilizes Centrifuge and Clari-Clean centrifuge bowl cleaner, which are mounted on cart to allow fluid cleaning operation to be brought to any machine. Portable system features 8 gpm circulation system and removes contaminants to standard drum, located on 6 x 3 ft cart.
|
Refrigerant Dehydrator operates continuously.Redi/Controls, Inc.
Greenwood, IN 46143 1406
Jul 28, 2006
Able to process 4,200 lb of refrigerant per week, Model CD-120 removes moisture, acid, sludge, and particulates from any flooded evaporator AC/R refrigeration systems. Totally automatic unit features 4 filter cores and uses only gravity, heat, and pressure differential to operate. For installation, dehydrator requires 120 Vac power supply and two 3/8 in. connections. Refrigerant charge does not have to be pulled to install.
|
 Side-Mount Cooling Units condition electronic enclosures.Pfannenberg
Lancaster, NY 14086
May 02, 2006
Offered in NEMA 12, NEMA 3R/4, and stainless steel NEMA 4/4X versions, DTS 3000 Series cools electrical and electronic enclosure applications in various industries. Capacities range from 4,000-20,000 BTU, and operating voltages are 115, 230, and 460 Vac. While stainless steel NEMA 4/4X unit is suited for all wash-down related applications, all units feature unobstructed airflow management for optimized cooling performance and energy management.
|
 Cooling Systems maintain enclosure temperature at 80-90°F.ITW Vortec
Cincinnati, OH 45242-4719
Apr 27, 2006
Suited for NEMA Type 4 and 4X rated electrical cabinets, UL listed, Vortex A/C(TM) cooling systems are available in 3 models that deliver 900, 1,500, or 2,500 Btu/hr. Units feature noise levels of 62 dBA and operate in environments up to 175°F. Vortex tube technology converts filtered compressed air into low pressure, refrigerated air stream.
|
 Heat Sinks cool condensed electronic packages.Advanced Thermal Solutions Inc.
Norwood, MA 02062
Jan 24, 2006
Fabricated from lightweight extruded aluminum, maxiFLOW(TM) heat sinks are utilized for cooling BGAs and hot components inside electronic systems. Featuring low profile spread fin arrays to enable convectional air cooling within restricted/low air flow conditions, they are available in lengths and widths ranging from 10 x 10 mm to 60 x 60 mm, and heights starting at 2 mm.
|
Thermoelectric Cooling Modules suit high power laser diodes.Elite Thermal Engineering
Bothell, WA 98021
Oct 05, 2005
Utilizing DCS technology, Cold Plates enable scalable cooling and mitigate heat-spreading problem of using both heatsink and cold plate. Technology is targeted for cooling high power laser diodes such as those found in material processing lasers, medical research, and high power fiber lasers. All cold plates have mounting patterns for most diodes, and custom patterns are available upon request.
|
 Coolant Delivery System provides automatic filtration.Knoll America, Inc.
Madison Heights, MI 48071
Jun 29, 2005 Capable of removing particles down to 25 microns from emulsions and oils, Turbo Force coolant delivery system automatically back-flushes contaminants into chip conveyor for individual machines or through central filtration system for multiple station operations. Available with pumps offering flow rates of 1-180 gpm at up to 1,750 psi, system is designed for high-volume, high-pressure applications in abrasive milling, turning, and drilling processes. |
 Cooling Tower Packing is compatible with all tower types.Tri-Mer Corp.
Owosso, MI 48867
Jun 22, 2005 Manufactured from 100% virgin polypropylene, Tri-Packs CT facilitates continuous formation of droplets throughout packed bed. Shape of ribs, struts, and drip rods give media optimal wetting characteristics and maintains uniform liquid distribution throughout tower. Free of corners and valleys, media eliminates puddling, while preventing dry spots and compression interlock. Supplied in 4 sizes, Tri-Packs CT is corrosion-proof and resistant to most chemicals. |