(Showing headlines 1 - 20) more ....
|
Thermoelectric Assemblies increase cooling in enclosures.Laird Technologies - EMI
St. Louis, MO 63045
Jul 27, 2009
Suited for telecom battery back-up systems and electronic integration enclosures in harsh environments, AA-100/-150/-200 Air-to-Air Outdoor Thermoelectric Cooler Assemblies feature solid-state operation and do not use compressor or CFC refrigerants. Elements of construction include waterproof connectors, high-density heat sinks with heavy-duty anodization, and overheat protection as well as double environmental seals, fans, and custom thermoelectric modules.
|
Transformer Cooling System optimizes heat transfer.Trantech Radiator Products
Edgefield, SC 29824
May 11, 2009
As 520 mm radiator, E4 optimizes heat dissipation via header diameter on inlet and exit path of oil. Enlarged sump conveys oil from inlet header to plates of radiator on inlet side, and similarly enlarged neck conveys oil from plates to exit header on outlet side. Plate spacing increases hydraulic diameter in plate for same perimeter, reducing friction factor for external flow of air. Improves heat transfer coefficient 18-22%, radiator maintains minimal valves and other connections.
|
 Front Panels also act as heat sinks.Elma Electronic Inc.
Fremont, CA 94538
Apr 29, 2009
Aluminum based black anodized Elma front panel heat sinks dissipate heat while covering open sections of enclosure. Cooling fin extrusion has width of 42 HP and comes in 1U high increments. Each fin is built upon 1.5 HP pitch to leave enough space in between for screw heads. Heat sink front panels come in various sizes and configurations, but are specifically designed for 19 in. technology. EMC versions with mounting bracket for gaskets are also available.
|
 Thermoelectric Cooler operates at low currents.Nextreme Thermal Solutions
Durham, NC 27003
Jan 29, 2009
Designed for optoelectronics and telecommunications industries, OptoCooler HV14 is optimized for standard circuitry and power requirements. It can pump up to 1.5 W of heat and operates at max voltage of 2.7 V and peak current of 1 A. Occupying 2.8 mm² footprint, unit can create temperature differential up to 51°C between its hot and cold sides. Thermal Copper Pillar Bump acts as solid-state heat pump to add thermal management functionality locally on surface.
|
 Cooling Sleeve allows video inspection of areas up to 500°F.Advanced Inspection Technologies
Melbourne, FL 32940
Jan 22, 2009
Videoscope cooling sleeve allows borescope inspectors to insert a videoscope into sleeve for remote visual inspection of high temperature applications. It keeps scope cool by surrounding it in vortex of compressed air, allowing users to inspect steam lines and turbines. Shop air is connected, which maintains appropriate temperature for videoscope to operate. Constructed of high temperature polyurethane, sleeve works with 3.0 m long videoscope.
|
 Condensate Evaporators feature CE and UL approval.Component Hardware Group, Inc.
Lakewood, NJ 08701
Nov 13, 2008
Suited for commercial refrigerators, Condensate Evaporators are available in 230 V/160 W and 230 V/254 W models. Both feature energy-efficient thermostatic control, and 50 oz/1,500 ml die-cast aluminum pan that is PTC-controlled and self-regulating to minimize power consumption when it is not needed. Plug, receptacle, cordset, and insulator pads are all CE approved, indicating conformity with essential health and safety requirements set forth by European Union.
|
 Cold Plate is designed for high power fiber coupled lasers.Elite Thermal Engineering
Bothell, WA 98021
Aug 22, 2008
Model OCP-150 is compact high power 150 W OEM thermoelectric, nickel-plated cold plate to maximize heat spreading for high heat flux laser diodes. It has mounting patterns for nLight's Pearl fiber coupled lasers, LIMO's fiber coupled lasers, and QPC's Brightlase Ultra. Heatsinks for OCP-150 have 3 heatpipes, and all heatpipes and heatsinks are nickel plated and soldered together to maximize heat transfer.
|
Central Cooling Plants have pre-engineered, modular design.McQuay International
Minneapolis, MN 55440
Aug 07, 2008
Pre-assembled to facilitate installation, modular central plants are suited for new construction and expansion projects where fast-track completion schedules or minimal interruption to cooling are priorities. Solutions combine water-cooled chiller with pumps, cooling tower, and interconnected piping. Chiller models include screw, scroll, centrifugal, or magnetic bearing compressor, depending on requirements, while cooling tower includes VFD as standard. Sizes range from 100-600 tons.
|
Peltier Devices are offered in compact sizes.CUI, Inc.
Beaverton, OR 97005
Jul 31, 2008
Offered in sizes 15 x 15, 20 x 20, and 30 x 30 mm with heights ranging from 3.3-5.1 mm, CPXXXXX Series Peltier Devices have no moving parts and are suited for applications where size and weight are limited. They provide input of 2.0-8.5 A, solder melting point of 138°C, and maximum compress of 98.07 N/cm². Available with heights from 3.8-4 mm, 40 x 40 mm version features input of 6.0-8.5 A.
|
 OEM Thermoelectric Cold Plate has dual butterfly mounts.Elite Thermal Engineering
Bothell, WA 98021
Jul 08, 2008
Featuring 2 model BA-01 butterfly mounts, OCP-050A stabilizes uncooled butterfly lasers using external TECs. It features aluminum cold plate and proprietary thermoelectric modules, which maintain enough cooling capacity for 2 of any high-power pump lasers. Butterfly lasers with internal thermoelectric coolers have lower power due to cooling capacity limit of internal TECs. Uncooled butterfly lasers provide higher power limited only by laser diode itself.
|
 Heating and Cooling Coils offered in choice of materials.Diversified Heat Transfer, Inc.
Ridgewood, NY 11385
Apr 10, 2008
Coils are manufactured from tube materials consisting of copper, 90/10 cupronickel, SS, or carbon steel. Steam Coils have standard steam and steam distributing coils. Also available are industrial HVAC heating and cooling air-handling coils and plate fin, helical fin, L-footed, and solder-bonded air coils with 3/8-1 in. OD tubing for steam and water applications. Econo Line shell and tube heat exchangers, 4-30 in., are offered in steam-to-liquid or liquid-to-liquid styles.
|
 Automatic Fogging Machine features dual timer assembly.Mist Cooling Inc
Richmond, TX 77469
Mar 20, 2008
Suited for industrial, residential, commercial, and hospitality applications, Model FM920 automatic fogging machine features ceramic piston sleeves for creating pressure of 920 psi. Dual timer assembly, with settings for minutes and seconds, allows users to set exact misting and stop times desired. Pump automatically stops when water supply is interrupted, and 0.1 mm mesh inlet filter prevents debris from entering pump.
|
 Tramp Oil Separator features compact design.Master Chemical Corporation
Perrysburg, OH 43552
Mar 12, 2008
Intended for use with water-miscible coolants and parts washing fluids, Master Coalescer Jr.(TM) works with CNC machines with small, hard to access coolant sumps. It includes removable media pack that provides up to 132 square ft of coalescing surface, and comes with electric 120 V diaphragm pump that primes to 48 in. Tramp oil separator is also available in portable model that features 2 rigid and 2 swivel casters and hinged pull handle with magnetic latch.
|
Thermoelectric Coolers have up to 100 W/cm² cooling power.Micropelt GmbH
Freiburg 79110 Germany
Oct 05, 2007
Supporting maximum temperature difference (delta T) of over 60° Kelvin, Series MPC-D303 microchip thermoelectric coolers (TECs) target laser and photonic sensor manufacturers. Fabricated on silicon wafer using standard semiconductor processes and soldered at 300°C, chip-sized TECs feature cold side area of only 0.98 mm². With maximum operating temperature of 200°C, they can realize temperature changes faster than 180° K/sec.
|
Cooling Systems protect workers from heat stress, fatigue.Salisbury Electrical Safety, LLC
Skokie, IL 60077
Sep 04, 2007
Mounted to short and full brim hardhats, PRO-AIR(TM) ACAIR3000(TM) provides forced ambient air throughout headwear to keep workers cool. Microprocessor-controlled unit, powered by rechargeable batteries, offers automatic and manual functions. Also available, ACAIR2000(TM) is designed for arc flash hood applications. It provides continuous air supply to worker while reducing hazardous effects of shield fogging. Rechargeable batteries offer 3 hr of continuous operation per charge.
|
 Temperature Controller works with fluid dispensing systems.Sealant Equipment & Engineering, Inc.
Plymouth, MI 48170-0965
Aug 17, 2007
Peltier series Thermoelectric Temperature Controller combines Peltier thermoelectric device, temperature sensor, and temperature control mounted to manifold where fluid passes through to be heated, maintained, or cooled. Mounted in-line or on fluid dispensing equipment, product uses Peltier-Seebeck effect to directly convert electrical voltage to thermal differentials and heat or cool fluid materials to temperature set point. Accessories are available.
|
Cooling Seat Cushion fits most cars, trucks, and SUVs.Nocord
Richmond, VA 23224
Jan 10, 2007
Utilizing centrifugal fan, SummerSeat pulls in fresh air to cool back and bottom of driver or passenger. Foam cushioning, microfiber mesh, and Eva(TM) Cooling Plastic promotes cool air flow, while adjustable cooling control lets user set desired level of comfort. Product draws minimal power from vehicle's battery and has energy saving automatic shut-off timer that deactivates seat every hour. Optional ac adapter is available for office use.
|
 Chip Conveyor features coolant filtration and separation.Mayfran International
Cleveland, OH 44143-0038
Sep 19, 2006
ConSep single-platform chip conveyor/coolant separator removes chips and contaminates to 50 microns in size. Separator has internal chip handling (auger) system, which also handles fines and sediment, and backwash that automatically cycles to indexing filter drum's poly fiber media, making unit maintenance free. Clear access panel enables visual inspection of cleaning process, and filtered coolant is held in holding tank for return to machine tool.
|
 Coolant System monitors volume and mix ratios.Mayfran International
Cleveland, OH 44143-0038
Sep 19, 2006
Mounted to machine coolant tank, Coolant Control Center (CCC) provides continuous real time in-line monitoring of coolant, measuring coolant concentration, PH, conductivity, temperature, and volume. System features PLC for coolant correction and programming routines for precise maintenance of machining fluids. Measuring 16.92 x 38.89 x 11.92 in., CCC has ¾ in. water inlet union and works with 220 V 2-phase electric connector or 400 V 3-phase power hookup.
|
 Fluid Recovery System can be moved to any location.Kinefac Corporation
Worcester, MA 01603-1260
Sep 18, 2006
Maneuverable in factory aisles, compact system removes solid contaminants from coolant and lubricant fluids used in metalworking processes. It utilizes Centrifuge and Clari-Clean centrifuge bowl cleaner, which are mounted on cart to allow fluid cleaning operation to be brought to any machine. Portable system features 8 gpm circulation system and removes contaminants to standard drum, located on 6 x 3 ft cart.
|
(Showing headlines 1 - 20) more ....
|
|
|
|
 |