Transformer Coolers feature portable design.Unifin International, Inc.
London, ON N6A4P4
Mar 19, 2007
Installed on transformer, ForZair(TM) HeatSink auxiliary coolers immediately reduce temperature of dielectric cooling oil. Units can be transferred from one overloaded substation to another, providing relief wherever it is needed most. They employ mono-aluminum extruded fin-tubes and Cardinal transformer oil pumps with glandless design that prevents leaks. To augment cooling on 1-60 Mva OA, FA, or FOA transformers, coolers come ready for fully self-contained operations.
|
 Automatic Cooler is used for dry-block calibration.AMETEK Test & Calibration Instruments
Largo, FL 33773
Mar 08, 2007
Capable of reaching temperatures from -90 to +125°C, JOFRA(TM) ATC-125 Ultra Cooler incorporates ATC Series dual-zone control technology to ensure precise temperature homogeneity throughout calibration well. Unit achieves cryogenic temperatures through Free Piston Stirling Cooler technology, which consists of Stirling heat pump in 290 g, compact unit. Helium gas acts as heat transport medium, while mains power variance immunity technology promotes temperature stability.
|
Cold Gun minimizes heat build-up in machining operations.EXAIR Corporation
Cincinnati, OH 45249-1621
Feb 01, 2007
Producing stream of 20°F air, High Power Cold Gun is suitable for continuous use without possibility of freezing up. Stainless steel vortex tube converts ordinary supply of compressed air into cold air, while flexible ball and socket hose directs cold air to point where heat is generated. Eliminating filtration, clean-up, and disposal of liquid coolants, gun is suited for laser cutting, tool sharpening, drill and cutter grinding, milling, drilling, and band sawing.
|
Graphics Cooler features micro thermofluidic core.Celsia Technologies
Miami, FL 33131
Dec 07, 2006
Iceon(TM) 1000CG graphics card cooling product offers manufacturers of graphics cards, boards, and PCs quiet operation while maintaining very low temparatures. Product includes fan packaged with NanoSpreader(TM) thin and light heat spreader technology, which enables slow fan speeds to increase fan life and decrease noise.
|
 Oil Coolers handle all overheating transformers.Unifin International, Inc.
London, ON N6A4P4
Dec 05, 2006
Designed for new transformers and for replacing existing installations that are overheating, ForZair(TM) Transformer Oil Coolers feature Mono-Aluminum extruded fin-tubes and plate fin technology. Units are available in forced oil-to-forced air, natural convection oil-to-water, and forced oil-to-water models, in 50 and 60 Hz versions. Hinged Fan Panels enable user to open cooler and pressure-wash fin surface. Coolers are pre-engineered to meet requirements of each application.
|
Cooler suits heat-intensive consumer and gaming CPUs.Celsia Technologies
Miami, FL 33131
Oct 26, 2006
With micro thermofluidic casing, Iceon(TM)1000C desktop cooler is built for cooling computers that are used for heat-intensive graphic and video-rich processing applications. Cooler includes fan along with lightweight 2-phase NanoSpreader(TM) heat spreader which uses razor-thin plates or tubes that integrate with any electronic device. Product offers quiet operation under extreme conditions.
|
 Generator Coolers feature removable cover plates.Unifin International, Inc.
London, ON N6A4P4
Sep 29, 2006
Designed with plate fin technology, RCP(TM) Coolers remove heat from electrical generators. Removable, bolt-on cover plate facilitates access for cleaning while keeping cooler installed, without disturbing piping. Leak detector configuration is available to prevent catastrophic failure of motor or generator. Coolers are suited for new and existing power generation installations, from nuclear and hydro-electric to gas turbine power.
|
 Graphite Heat Exchanger utilizes multiple bundles.SGL Carbon Technic, LLC
Strongsville, OH 44149
Sep 28, 2006
Allowing operation in countercurrent flow regime, Model RM Multi-Tube Bundle Exchanger handles applications with close temperature approaches or temperature crosses. Bundle modules can be removed for cleaning, inspection, or replacement. Impervious graphite exchangers are used for heating and cooling corrosive chemicals such as hydrochloric acid, sulfuric acid, and phosphoric acid.
|
Horizontal Row Cooler suits high density computer systems.Emerson Network Power
St. Louis, MO 63136
Sep 15, 2006
Utilizing waterless pumped refrigerant technology, Liebert XDH is designed for data center applications where there is limited overhead space due to overhead cabling or low ceiling height. Unit fits within row of electronic equipment racks inside hot-aisle-cold-aisle arrangement. Able to cool more than 30 kW per rack, Liebert XDH features flexible piping with quick-connect fittings that allow expansion as well as re-positioning without interruption of cooling.
|
 Rack Mount Coolers come in 110 cfm and 375 cfm models.BMF Power
Abington, MA 02351
Sep 06, 2006
Utilizing dual radial airflow ball-bearing fan systems, RMF Series is available in 1U and 2U high packages that provide rack heat extraction and system temperature control. Up and Out design draws heated air from rack up into fan system and out back of rack, drawing damaging heat away from sensitive system components. Optional front panel mounted, digital thermometer with remote probe enables monitoring of overall rack temperature conditions from -4 to +428°F.
|
 LFT Chassis includes closed-loop liquid cooling system.Parker Hannifin Corp.
Oxford, MI 48371
Jun 26, 2006
Designed for defense and aerospace applications, Liquid Flow-Through (LFT) Electronics Chassis incorporates coolant, control system, smart pump, filter, accumulator, heaters for cold-system startup, and 3 different board-level heat-absorbing technologies. It is capable of cooling up to maximum of 850 W/slot, total of 2,000 W with dielectric fluids such as hydrofluoroethers and synthetic oil, or 4,000 W with non-dielectric fluids like water or water/glycol mixtures.
|
Cabinet Coolers offer side mounting kits.EXAIR Corporation
Cincinnati, OH 45249-1621
May 18, 2006
Side Mount Kits for Cabinet Coolers enable mounting to side of electrical enclosure for applications where top mounting is not possible due to limited space or obstructions. Coolers circulate 20°F air throughout enclosure, protecting sensitive electronics from heat, dirt, and moisture while maintaining NEMA 4/4X rating of enclosure. Side Mount Kits are suited for large or small electrical enclosures with Cabinet Coolers having capacities to 2,800 btu/hr.
|
 Light Scattering Detector analyzes pharmaceutical compounds.Polymer Laboratories, Inc.
Amherst, MA 01002
May 12, 2006
Evaporative Light Scattering Detector, Model PL-ELS 2100, is available with optional Integrated Cooled Evaporator, Model PL-ELS 2100 Ice, which operates at temperatures down to 10°C to meet requirements for pharmaceutical analysis of non-UV absorbing, low molecular weight, semi-volatile analytes. Addition of evaporation gas not only allows low temperature operation with aqueous mobile phases, but also facilitates removal of water at sub-ambient temperatures.
|
 Cooling Systems maintain enclosure temperature at 80-90°F.ITW Vortec
Cincinnati, OH 45242-4719
Apr 27, 2006
Suited for NEMA Type 4 and 4X rated electrical cabinets, UL listed, Vortex A/C(TM) cooling systems are available in 3 models that deliver 900, 1,500, or 2,500 Btu/hr. Units feature noise levels of 62 dBA and operate in environments up to 175°F. Vortex tube technology converts filtered compressed air into low pressure, refrigerated air stream.
|
Sanitary Sample Coolers allow safe taking of samples.Carltex Inc
Greenlawn, NY 11740
Feb 27, 2006
Designed for use in pharmaceutical plants and clean rooms, Sanitary Sample Coolers are constructed of polished 316L SS to take samples from steam or heated water systems for chemistry/TOC, conductivity, and microbiological studies. Available both fixed or portable, cooler includes bracket for wall mounting and can be steam sterilized or de-pyrogenated using a hot air process.
|
 Sand and Gravel Cooler creates optimal packaging conditions.Carman Industries Inc.
Jeffersonville, IN 47130
Oct 13, 2005
Operating at 150 TPH, Carman Sand Cooler works with rotary dryers to reduce temperature and moisture. Vibrating fluid bed sand and gravel cooler, able to reduce product temperature from 225°F to 150°F, uses ambient air evaporative cooling and stores cool, dry product, without condensation, in plastic packaging. Construction includes wear liner in inlet chute, ¼ in. thick air distribution deck, and integral exhaust manifold. Reactive counterbalance minimizes vibration transmission.
|
 Evaporative Cooler has space-saving design.Champion Cooler Corp.
Little Rock, AR 72209 2543
Aug 08, 2005 Designed for use in residential areas, model N30G complies with most homeowner's association codes, covenants, and restrictions. It extends 12 in. from house and features bi-directional grille that adjusts vertically and horizontally. Equipped with 1/3 hp direct drive motor, cooler has solid steel cabinet with powder coat finish and comes with installation kit. UL-listed unit cools garages, storage spaces, and workrooms. |
 Portable Evaporative Cooler increases worker comfort.Cool-Space, Inc.
Fishers, IN 46038
May 04, 2005 Designed for cooling individual workers as well as spot cooling in open spaces, COOLSPACE Jr. utilizes 3 in. thick cross corrugated cooling pads and 2-speed centrifugal blower. It provides up to 20° cooler air for hours with 12 gal reservoir. Stand-alone unit can also be connected to garden hose for automatic water level maintenance. Mounted on 4 casters, portable unit has recessed, rubber-matted top for tools and operates from 115 V electrical supply. |
Cabinet Coolers suit large electrical enclosures.EXAIR Corporation
Cincinnati, OH 45249-1621
Apr 12, 2005
Rated at 2,800 btu/hr, Cabinet Coolers mount to NEMA 12, 4, or 4X enclosures through standard electrical knockout to protect electronics from harsh environments. Vortex tube cools ordinary compressed air to 20°F, while automatic drain filter separator ensures no moisture passes to inside of enclosure. Thermostat control minimizes compressed air use and keeps enclosure at ±2ºF of temperature setting. All models are UL Listed to US and Canadian standards.
|
Truck HVAC System drives engine accessories electrically.Caterpillar, Inc.
Peoria, IL 61629
Apr 12, 2005 MorElectric System provides electrically powered heating, ventilating, and air-conditioning system, allowing all HVAC components to be removed from engine compartment. Electric power comes from 7,300 W generator that replaces alternator. When coupled with Auxiliary Power Unit, system provides driver with comfortable cab environment when main engine is off. Using Shore Power, truck is plugged into pedestal at truck stop, providing low emission idling solution. |