ThomasNet News Logo
Sign Up | Log In | ThomasNet Home | Promote Your Business
 Journals
Industry Market Trends ®
Fluid & Gas Flow Journal
Machining Journal
Procurement Journal
Tech Trends Journal
 Industry News
Latest New Product News
Association & Government News
Thought Leaders
 Product News
Adhesives and Sealants
Agricultural and Farming Products
Architectural and Civil Engineering Products
Automatic ID
Chemical Processing and Waste Management
Cleaning Products and Equipment
Communication Systems and Equipment
Computer Hardware and Peripherals
Construction Equipment and Supplies
Controls and Controllers
Display and Presentation Equipment
Electrical Equipment and Systems
Electronic Components and Devices
Explosives, Armaments and Weaponry
Fasteners and Hardware
Fluid and Gas Flow Equipment
Food Processing and Preparation
Green & Clean
Health, Medical and Dental Supplies and Equipment
HVAC
Labels, Tags, Signage and Equipment
Laboratory and Research Supplies and Equipment
Lubricants
Machinery and Machining Tools
Material Handling and Storage
Materials and Material Processing
Mechanical Components and Assemblies
Mechanical Power Transmission
Mining, Oil Drilling & Refining
Mounting and Attaching Products
Non-Industrial Products
Optics and Photonics
Packaging Products & Equipment
Paints and Coatings
Plant Furnishings and Accessories
Portable Tools
Printing and Duplicating Equipment
Retail and Sales Equipment
Robotics
Safety and Security Equipment
Sensors, Monitors and Transducers
Services
Software
Test and Measuring Instruments
Textile Industry Products
Thermal and Heating Equipment
Timers and Clocks
Transportation Industry Products
Vision Systems
Waste Handling Equipment
Welding Equipment and Supplies
 Press Releases
Products in the News
Company News
Mergers & Acquisitions
People in the News
Literature & Websites
 Resources
News Delivery Options
Newsletter Archive
SME
Browse Categories
Browse Companies
Mobile Edition
PR Resources
Licensing
Advertising
Call for Contributors, Guest Writers and Submissions
How to Write an effective Press Release
Trade Associations
HVAC -> Cooling Equipment -> Coolers


Coolers




(Showing headlines 1 - 20)   more ....
Cryogenic Cooler provides efficiency, longer life.

Cryogenic Cooler provides efficiency, longer life.

Sunpower, Inc    Athens, OH 45701
Aug 27, 2014 Optimized for power density, operational life, and efficiency, CryoTel® DS 1.5 Stirling Cryocooler features dual-opposed-piston pressure wave generator and separate cold head to minimize exported vibration and acoustic noise. Optional passive balancer further reduces cold head vibration for sensitive applications. With nominal heat lift of 1.5 W at 77 K, cooler can be employed anywhere liquid nitrogen is used and where temperatures reach 125 to 40 K.

Thermoelectric Air Conditioners cool small enclosures.

Thermoelectric Air Conditioners cool small enclosures.

Thermoelectric Cooling America Corp. (TECA)    Chicago, IL 60639
Jun 25, 2014 Measuring 6 x 4.75 x 6.6 in., Models AHP-250 and AHP-270 offer 129 BTU/hr and 161 BTU/hr, respectively. Enclosure coolers are built with industrial or military grade fans and are suitable for range of environments including mil-spec and NEMA-4X enclosures. Offering maintenance-free electronics protection solution for hard-to-access areas, coolers are suited for military cases, mobile electronics, alarm systems, communications, cameras, and even small kiosks.

Thermoelectric Air Conditioners keep electronics cabinet cool.

Thermoelectric Air Conditioners keep electronics cabinet cool.

Thermoelectric Cooling America Corp. (TECA)    Chicago, IL 60639
May 28, 2014 Available for systems with 3-phase power, thermoelectric electrical cabinet coolers offer cooling capacities from 2,200–6,000 BTU/hr and do not require filters, coolant, or chemicals. Only moving parts are industrial- and military-grade fans, and built-in temperature controller offers Eco-Mode for energy conservation. Able to perform in diverse environments, including NEMA-12/-4/-4X, these maintenance-free air conditioners also come in Heat/Cool versions and can be customized.

Filter Fans cool electrical and electronic enclosures.

EIC Solutions, Inc.    Warminster, PA 18974-1157
May 27, 2014 Designed to remove unwanted heat from enclosures and cabinets, VFF Series provides forced convection cooling for computers, power distribution equipment, industrial automation controls, and food/beverage process controls. Fans draw filtered ambient air into cabinet while simultaneously blowing heated air out exhaust. Featuring injection molded, thermoplastic construction, fans provide 11–368 cfm of airflow and will maintain NEMA ratings of 12, 3R, or 4, depending on model.

Dual Tower CPU Cooler provides quiet operation.

Noctua, Inc.    Mountain View, CA 94043
Apr 18, 2014 Featuring 150 mm wide fin-stack and widely spaced heatpipes, Model NH-D15 enables uniform heat distribution for optimal efficiency. Recessed lower fins enable NH-D15 to provide 64 mm clearance for tall memory heatsinks in single fan mode. Cooler also features pro-grade SecuFirm2™ multi-socket mounting system and NF-A15 fans that support PWM for automatic speed control through mainboard. Using supplied Low-Noise Adapter, max fan speed can be reduced to 1,200 rpm for quieter operation.

Electrical Cabinet Coolers are resistant to heat and dirt.

Electrical Cabinet Coolers are resistant to heat and dirt.

Exair Corp.    Cincinnati, OH 45249-1621
Apr 16, 2014 By circulating 20°F air throughout electrical enclosures in hot, remote, and/or dirty environments, NEMA 12 Cabinet Cooler® Systems prevent high temperature malfunctions. Cooling capacity of up to 275 Btu/hr suits small electrical enclosures with problematic overheating, and models with 550 Btu/hr capacities are also available. Mounting through standard electrical knockout while maintaining NEMA 12/4/4X rating of enclosure, maintenance-free systems do not have any moving parts.

Hydration Packs help combat worker heat stress.

Hydration Packs help combat worker heat stress.

Ergodyne    St. Paul, MN 55108
Mar 25, 2014 Offering 600D water-resistant polyester shell with 2 L bladder, Chill-Its® Hydration Series provides on-the-go hydration solution for workers in extreme environments. Closed cell insulation keeps water cool for hours while TPE polymer bladder maintains taste of water. Shoulder straps are vented for breathability and have 8 mm EVA foam padding for comfort. For workers who need added protection of staying seen on the job, 5155HV model is available in hi-vis orange as well as lime.

CPU Coolers feature pulse width modulation.

CPU Coolers feature pulse width modulation.

FZtech Inc    New Taipei City 235  Taiwan
Jan 30, 2014 Compatible with Intel® LGA1366 type CPUs up to 85 W, Freezer 120 Series is available with pulse width modulation, with fan speed changing automatically, based on CPU loading activity. Fan speed operates within range of 800–4500 rpm with maximum airflow of 27.02 cfm and noise range of 0–39 dBA. Measuring 90 x 90 x 26.5 mm, coolers have 2 ball bearings and are rated for 12 V operation.

Thermoelectric Air Conditioner has half ton cooling capacity.

Thermoelectric Air Conditioner has half ton cooling capacity.

Thermoelectric Cooling America Corp. (TECA)    Chicago, IL 60639
Jan 24, 2014 Model AHP-6263 is 3-phase, 240 Vac air conditioner configured for use in NEMA-12/-4/-4X environments. Cooling using 86% less energy than active cool mode, Eco-Mode promotes energy conservation via built-in temperature controller that provides passive cooling. Customization is available, as is 250 Vdc version for crane applications.

Refrigerator Cryostat offers alternative to liquid helium.

Refrigerator Cryostat offers alternative to liquid helium.

Janis Research Co., Inc.    Wilmington, MA 01887
Jan 17, 2014 Operating continuously from 1.5–300 K, Model PTSHI-950-LT 1.5 K offers cryogen-free, turnkey alternative to liquid helium. Top-loading, closed-cycle system features pushbutton sample temperature adjustment and 50.8 ID sample chamber. Capable of achieving 1.5 K in less than 8 hours, system can locate sample in either static exchange gas or vacuum. Applications include neutron scattering, electrical transport measurements, magnetic measurements, optical spectroscopy, and spintronics.

Thermoelectric Air Conditioners keep electronic enclosures cool.

Thermoelectric Air Conditioners keep electronic enclosures cool.

EIC Solutions, Inc.    Warminster, PA 18974-1157
Nov 11, 2013 Used for cooling electronic enclosures, ThermoTEC thermoelectric coolers offer sustained, peak performance in environments with temperatures as high as 170°F. Select models can be configured to operate in ambient temperatures up to 190°F. NEMA 4X rating enables use indoors or outdoors, while solid-state electronics and lack of moving parts (except fans) minimize maintenance concerns. Sizes range from 200–2,500 BTU, and temperature can be controlled to within fractions of 1°.

Vent Free Recirculating Coolers promote flexible placement.

Julabo USA, Inc.    Allentown, PA 18109
Sep 19, 2013 Operated with set point entered via 3-key control panel, F series features stainless steel construction with centrifugal pump. Temperatures can be read from distance on LED display, and PID temperature control ensures temperature stability of ±0.5°C. Smallest model, F250, provides -10 to +40°C temperature range with 250 W of cooling capacity at 20°C, while F500 features 500 W capacity and integrated pump that delivers 24 Lpm at 7.1 psi. Bath fluid filling port is accessible on top.

Enclosure Cooling Units offer multiple mounting options.

Enclosure Cooling Units offer multiple mounting options.

EIC Solutions, Inc.    Warminster, PA 18974-1157
Sep 16, 2013 With different mounting options, Thermoelectric Air Conditioners for electronic enclosures help users meet varying installation space requirements. Standard through-mount option assures optimum airflow which promotes efficient cooling of cabinet contents. If there is no room in enclosure interior, extension frame mount is available which creates alcove in cabinet panel. Conversely, recessed frame mount places cooling unit entirely within cabinet so that all external enclosure surfaces are flat.

CPU Coolers offer pulse width modulation option.

CPU Coolers offer pulse width modulation option.

FZtech Inc    New Taipei City 235  Taiwan
Aug 08, 2013 Measuring 60 x 58 x 31 mm, Freezer 200 Series is compatible with Intel® Mobile type CPUs up to 65 W. Standard 2-ball bearing units feature fan speed of 5,300 rpm with airflow of 11.06 cfm and 33 dBA noise. With PWM, fan speed changes automatically based on CPU loading activity. PWM-enabled models support fan speeds from 500–5,300 rpm with max airflow of 11.06 cfm and noise range of 14–33 dBA. All fans used in coolers have rated voltage of 12 V.

CPU Coolers include fans with automatic speed control.

Noctua, Inc.    Mountain View, CA 94043
May 24, 2013 Model NH-U12DX i4 CPU coolers feature NF-F12 120 mm fan and 45 mm fin depth, allowing access to RAM slots. Integrating two NF-B9 92 mm fans, NH-U9DX i4 units measure 125 mm high, supporting use with standard 4U server cases. Products support LGA1356, LGA1366, and square and narrow ILM LGA2011-based Xeon platforms. They are fitted with SecuFirm2™ mounting system and include industrial-grade NT-H1 thermal compound and low-noise adaptors to minimize fan speed and noise.

A/C Electronics Enclosure Coolers conserve compressed air use.

A/C Electronics Enclosure Coolers conserve compressed air use.

ITW Vortec    Cincinnati, OH 45242-4719
May 16, 2013 Providing protection for electrical and electronic components, Vortex A/C Enclosure Cooler models 7770, 7670, and 7570 offer 5,000 BTU/hr cooling capacity and employ 2-stage cooling system that helps conserve compressed air. Only first cooling stage is used during regular usage, but second cooling stage is activated when cooling demand increases. Additionally, model 7570 is designed for hazardous locations and UL Classified for use in Class I, Div 2; Class II, Div 2; and Class III areas.

Cooling Package suits industrial engines in harsh environments.

Volvo Penta Of The Americas, Inc.    Chesapeake, VA 23320
May 01, 2013 Able to withstand cleaning with high-pressure water, Heavy-Duty Cooling Packages are available on 2013 Volvo Penta D5, D7, D13, and D16 Stage IIIB/Tier 4i engines as well as D13 and D16 Stage II engines, which cover 129–565 kW range. Systems are available as suction- and pusher-type models for all heavy-duty radiator units. Heavy-duty cable harnesses use split synthetic polyester tubing as cable protection. Wrapped around cables, tubing making cables practically immobile, even at high vibrations.

Slim Single-Tower CPU Coolers deliver quiet operation.

Noctua, Inc.    Mountain View, CA 94043
Apr 17, 2013 While NH-U12S comes with NF-F12, 120 mm FocusedFlow™ fan, NH-U14S features 6 heatpipe design and NF-A15, 140 mm fan. Both fans support PWM for automatic speed control through mainboard, and max fan speed can be reduced from 1,500–1,200 rpm using supplied Low-Noise Adaptor for quieter operation. Design facilitates RAM access and promotes compatibility with tall memory modules. Other standard features include pro-grade SecuFirm2™ multi-socket mounting system and NT-H1 thermal compound.

Stainless Steel Cabinet Coolers resist heat and corrosion.

Stainless Steel Cabinet Coolers resist heat and corrosion.

Exair Corp.    Cincinnati, OH 45249-1621
Apr 12, 2013 Resistant to wear, corrosion, and oxidation, Dual 316 Stainless Steel Cabinet Cooler® Systems circulate 20°F air throughout electrical enclosure to prevent malfunctions due to elevated temperatures. Available cooling capacities include 4,000, 4,800, and 5,600 Btu/hr, and automatic drain filter separator ensures no moisture passes to inside of electrical enclosure. Optional thermostat control minimizes compressed air use and keeps enclosure at ±2°F of temperature setting.

Hydraulic Oil Coolers serve mobile and industrial markets.

Parker Hannifin Corporation    Cleveland, OH 44124
Feb 11, 2013 Heavy-duty hydraulic oil coolers are offered in 4 designs to accommodate needs of mobile and industrial applications. For industrial use, ULAC with AC motor has 400 hp max cooling capacity. ULOC cooling system, with 60 HP max cooling capacity, is also suited for industrial use. Mobile applications are accommodated via ULDC with DC motor which has 40 hp max cooling capacity and ULHC with hydraulic motor, which also serves industrial use and has 215 hp max cooling capacity.




(Showing headlines 1 - 20)   more ....


Home  |  My ThomasNet News®  |  Industry Market Trends®  |  Submit Release  |  Advertise  |  Contact News  |  About Us
Brought to you by Thomasnet.com        Browse ThomasNet Directory

Copyright © 2014 Thomas Publishing Company. All Rights Reserved.
Terms of Use - Privacy Policy