Air Conditioning Unit is designed for marine industry.Dometic Corp., The
Elkhart, IN 46516
Dec 22, 2006
Marine Air SVCD30 is supplied in seawater-cooled, framed package with single 30,000 BTU compressor/condenser and dual 16,000 BTU evaporator/blower assemblies mounted back-to-back on one chassis. Self-contained for limited-space applications, this 30,000 BTU unit draws return air from 1 or 2 compartments across both evaporator coils and ducts discharge air to 2 or more spaces. Stainless-steel chassis and Heresite coating for exposed components lend to corrosion resistance.
|
Air Conditioning Unit targets salt-air marine environments.Dometic Corp., The
Elkhart, IN 46516
Dec 20, 2006
Developed for jack-up boats and barges, 14,000 BTU air-cooled Model SSA14K includes compressor, evaporator, blower, and other mechanical and electrical components on single chassis that is bolted directly to deck. Built-in return-air and discharge-air plenums cool compartment directly below without duct runs. Chassis and enclosure are stainless steel, while condenser and other components are Heresite-coated for additional corrosion protection.
|
Chiller Unit is suited for large yachts and work boats.Dometic Corp., The
Elkhart, IN 46516
Dec 14, 2006
Designed for circulated-water air conditioning systems, Model MTS25-2 chiller module features hermetic scroll compressor and shell-and-tube marine-grade cupronickel condenser, along with other mechanical and electrical components, on single chassis. With space-saving design that facilitates installation in tight spaces, 25-ton unit also provides front access to condenser tubes, heater rods, flow switch, compressor and replaceable drier cores for repair and maintenance.
|
Graphics Cooler features micro thermofluidic core.Celsia Technologies
Miami, FL 33131
Dec 07, 2006
Iceon(TM) 1000CG graphics card cooling product offers manufacturers of graphics cards, boards, and PCs quiet operation while maintaining very low temparatures. Product includes fan packaged with NanoSpreader(TM) thin and light heat spreader technology, which enables slow fan speeds to increase fan life and decrease noise.
|
 Oil Coolers handle all overheating transformers.Unifin International, Inc.
London, ON N6A4P4
Dec 05, 2006
Designed for new transformers and for replacing existing installations that are overheating, ForZair(TM) Transformer Oil Coolers feature Mono-Aluminum extruded fin-tubes and plate fin technology. Units are available in forced oil-to-forced air, natural convection oil-to-water, and forced oil-to-water models, in 50 and 60 Hz versions. Hinged Fan Panels enable user to open cooler and pressure-wash fin surface. Coolers are pre-engineered to meet requirements of each application.
|
Cooling Unit is suited for wiring closets and server rooms.American Power Conversion
West Kingston, RI 02892
Nov 21, 2006
Capable of providing up to 7 kW of cooling capacity, InfraStruXure® InRow(TM) SC has modulating capacity control and variable speed fans providing required amount of cooling even in lightly loaded situations. Network manageability feature via web, SMNP, and Telnet helps in predictive failure notification while hot-swappable fan modules minimize mean-time-to-recovery. Self contained 12 in. wide (half-rack) solution helps measure and report cooling capacity for real-time capacity management.
|
Cooler suits heat-intensive consumer and gaming CPUs.Celsia Technologies
Miami, FL 33131
Oct 26, 2006
With micro thermofluidic casing, Iceon(TM)1000C desktop cooler is built for cooling computers that are used for heat-intensive graphic and video-rich processing applications. Cooler includes fan along with lightweight 2-phase NanoSpreader(TM) heat spreader which uses razor-thin plates or tubes that integrate with any electronic device. Product offers quiet operation under extreme conditions.
|
Cooling Modules come in ceiling and rack mount models.Emerson Network Power
St. Louis, MO 63136
Oct 23, 2006
Available in nominal 20 kW rating, Liebert XDO overhead, ceiling-mounted fan coil draws hot air from hot aisle and exhausts cool air vertically down into cold aisle. Mounted on top of rack or suspended from ceiling, Liebert XVD vertical fan coil offers nominal 10 kW rating. It draws hot air from hot aisle or rack and exhausts cold air into cold aisle where equipment air intakes are located. Both use waterless pumped refrigerant technology, eliminating potential for water damage.
|
 Generator Coolers feature removable cover plates.Unifin International, Inc.
London, ON N6A4P4
Sep 29, 2006
Designed with plate fin technology, RCP(TM) Coolers remove heat from electrical generators. Removable, bolt-on cover plate facilitates access for cleaning while keeping cooler installed, without disturbing piping. Leak detector configuration is available to prevent catastrophic failure of motor or generator. Coolers are suited for new and existing power generation installations, from nuclear and hydro-electric to gas turbine power.
|
 Graphite Heat Exchanger utilizes multiple bundles.SGL Carbon Technic, LLC
Strongsville, OH 44149
Sep 28, 2006
Allowing operation in countercurrent flow regime, Model RM Multi-Tube Bundle Exchanger handles applications with close temperature approaches or temperature crosses. Bundle modules can be removed for cleaning, inspection, or replacement. Impervious graphite exchangers are used for heating and cooling corrosive chemicals such as hydrochloric acid, sulfuric acid, and phosphoric acid.
|
 Chip Conveyor features coolant filtration and separation.Mayfran International
Cleveland, OH 44143-0038
Sep 19, 2006
ConSep single-platform chip conveyor/coolant separator removes chips and contaminates to 50 microns in size. Separator has internal chip handling (auger) system, which also handles fines and sediment, and backwash that automatically cycles to indexing filter drum's poly fiber media, making unit maintenance free. Clear access panel enables visual inspection of cleaning process, and filtered coolant is held in holding tank for return to machine tool.
|
 Coolant System monitors volume and mix ratios.Mayfran International
Cleveland, OH 44143-0038
Sep 19, 2006
Mounted to machine coolant tank, Coolant Control Center (CCC) provides continuous real time in-line monitoring of coolant, measuring coolant concentration, PH, conductivity, temperature, and volume. System features PLC for coolant correction and programming routines for precise maintenance of machining fluids. Measuring 16.92 x 38.89 x 11.92 in., CCC has ¾ in. water inlet union and works with 220 V 2-phase electric connector or 400 V 3-phase power hookup.
|
 Fluid Recovery System can be moved to any location.Kinefac Corporation
Worcester, MA 01603-1260
Sep 18, 2006
Maneuverable in factory aisles, compact system removes solid contaminants from coolant and lubricant fluids used in metalworking processes. It utilizes Centrifuge and Clari-Clean centrifuge bowl cleaner, which are mounted on cart to allow fluid cleaning operation to be brought to any machine. Portable system features 8 gpm circulation system and removes contaminants to standard drum, located on 6 x 3 ft cart.
|
Horizontal Row Cooler suits high density computer systems.Emerson Network Power
St. Louis, MO 63136
Sep 15, 2006
Utilizing waterless pumped refrigerant technology, Liebert XDH is designed for data center applications where there is limited overhead space due to overhead cabling or low ceiling height. Unit fits within row of electronic equipment racks inside hot-aisle-cold-aisle arrangement. Able to cool more than 30 kW per rack, Liebert XDH features flexible piping with quick-connect fittings that allow expansion as well as re-positioning without interruption of cooling.
|
Fan Tray features cross-flow cooling technique.New Age Fans
Fairfield, NJ 07004
Sep 13, 2006
Baffled fan tray utilizes cross-flow cooling fan and features adjustable depth as well as local and remote alarms. Due to its unique configuration, tray requires only 75 cfm. This low-wattage (6 W), 19 in. rack-mount fan tray assembly is CSA-, NEBS-, and UL-compliant. Applications include cooling of rack- and cabinet-mounted electronic equipment in telecommunications, commercial, military, and electronic industries.
|
 Rack Mount Coolers come in 110 cfm and 375 cfm models.BMF Power
Abington, MA 02351
Sep 06, 2006
Utilizing dual radial airflow ball-bearing fan systems, RMF Series is available in 1U and 2U high packages that provide rack heat extraction and system temperature control. Up and Out design draws heated air from rack up into fan system and out back of rack, drawing damaging heat away from sensitive system components. Optional front panel mounted, digital thermometer with remote probe enables monitoring of overall rack temperature conditions from -4 to +428°F.
|
Air Conditioners utilize nanotechnology.Rittal Corporation
Springfield, OH 45504
Aug 31, 2006
Suited for use in industrial environments where dust and oil-laden air can clog condenser coils, TopTherm air conditioners are manufactured with condenser coil designed with RiNano protective coating. Comprised of different classes of nanoparticles, RiNano forms solid, homogeneous bond with condenser surface. This produces glass-like surface layer that repels water, dirt, and oil, promoting long-term constant cooling performance.
|
 Bulk Powder Cooling System provides zero emissions.Solex Thermal Science, Inc. (formerly Bulkflow Technologies, Inc.)
Calgary, AB T2Z3V6 Canada
Aug 16, 2006
Equipped with tube exchanger that minimizes thermal stress and accommodates thermal expansion, Bulk Powder Cooling System cools bulk solids with temperatures up to 1,832°F. Bulk powder flows via gravity over water-cooled tubes. Geometry of tubes is uniform with even temperatures throughout tube wall to avoid hot spots and high local stresses. Integrating with existing equipment, system helps prevent product attrition and caking.
|
Refrigerant Dehydrator operates continuously.Redi/Controls, Inc.
Greenwood, IN 46143 1406
Jul 28, 2006
Able to process 4,200 lb of refrigerant per week, Model CD-120 removes moisture, acid, sludge, and particulates from any flooded evaporator AC/R refrigeration systems. Totally automatic unit features 4 filter cores and uses only gravity, heat, and pressure differential to operate. For installation, dehydrator requires 120 Vac power supply and two 3/8 in. connections. Refrigerant charge does not have to be pulled to install.
|
 LFT Chassis includes closed-loop liquid cooling system.Parker Hannifin Corp.
Oxford, MI 48371
Jun 26, 2006
Designed for defense and aerospace applications, Liquid Flow-Through (LFT) Electronics Chassis incorporates coolant, control system, smart pump, filter, accumulator, heaters for cold-system startup, and 3 different board-level heat-absorbing technologies. It is capable of cooling up to maximum of 850 W/slot, total of 2,000 W with dielectric fluids such as hydrofluoroethers and synthetic oil, or 4,000 W with non-dielectric fluids like water or water/glycol mixtures.
|