|
|
Advertisement
|
|
HVAC ->
Cooling Equipment
Cooling Equipment
(Showing headlines 41 - 60) 1 2 3 4 5 6 7 8 9 10 11 12
|
Packaged Assembly cools condensate and hot water.Cemline
Cheswick, PA 15024
Nov 30, 2007
Condensate After Coolers/Leg Assembly mix hot water with cold water, resulting in liquid temperatures acceptable for municipal sewage and local codes. Installed after flash tank, blow down tank, or condensate receiver, after cooler is supplied with check valve, cooling valve (½, ¾, or 1 in.), and thermometer. Unit can be mounted horizontally or vertically, and self-acting thermostatic cooling valve can be field-adjusted to desired set point from 77 to 150°F.
|
Compressor Chiller is available from 30-180 tons.McQuay International
Minneapolis, MN 55440
Oct 10, 2007
McQuay air-cooled scroll compressor chiller is available with R-410A refrigerant that is chlorine-free and has no ozone depletion potential. With up to 10.3 EER at full load and up to 14.7 EER at part load, chiller meets or exceeds ASHRAE Standard 90.1 for energy efficiency. McQuay Open Choices(TM) feature allows MicroTech II® controls to integrate into building automation systems using open, standard protocols such as LonTalk®, BACnet® or Modbus®.
|
Thermoelectric Coolers have up to 100 W/cm² cooling power.Micropelt GmbH
Freiburg 79110 Germany
Oct 05, 2007
Supporting maximum temperature difference (delta T) of over 60° Kelvin, Series MPC-D303 microchip thermoelectric coolers (TECs) target laser and photonic sensor manufacturers. Fabricated on silicon wafer using standard semiconductor processes and soldered at 300°C, chip-sized TECs feature cold side area of only 0.98 mm². With maximum operating temperature of 200°C, they can realize temperature changes faster than 180° K/sec.
|
Refrigerating/Heating Circulators feature 13 L reservoir.PolyScience Div. Of Preston Industries Inc.
Niles, IL 60714 4588
Sep 20, 2007
Offering precise temperature control for range of applications, 9500 Series is available with choice of 3 controllers and integrated simplex or duplex pump. Products are capable of operating temperatures up to 200°C and provide cooling capability down to -30°C with ±0.01°C temperature stability. Model 9512 features programmable controller with LCD, multi-language help menus, and time/temperature programming. It stores up to ten 50-step programs and offers data logging capability.
|
Immersion Coolers achieve temperatures as low as -100°C.PolyScience Div. Of Preston Industries Inc.
Niles, IL 60714 4588
Sep 20, 2007
Offering alternative to dry ice and liquid nitrogen, VLT Series can be used to achieve low temperature capability with non-refrigerated circulators or boost cooling capacity of refrigerated circulators. Non-controlled models provide temperatures from -40 to -100°C, while controlled models achieve temperatures from -40 to -85°C. Equipped with rigid coil probe, coolers are suited for use with solvent traps, freeze point apparatus, impact testing, and lyophilization.
|
Precision Cooling System is offered in 3 upflow models.Emerson Network Power
St. Louis, MO 63136
Sep 14, 2007
Available in capacities of 28, 35, and 42 kW, Liebert DS(TM) systems provide support for applications that require cooling delivered from top of unit (upflow). Use of digital scroll compressors allows capacities to adapt to room condition changes as small as ±1°F and ±1% RH, and Paradenser condenser system permits use of green refrigerants. Liebert iCOM(TM) control system, which provides diagnostic and maintenance support, also enables multiple units to communicate and work together.
|
Cooling Systems protect workers from heat stress, fatigue.Salisbury Electrical Safety, LLC
Skokie, IL 60077
Sep 04, 2007
Mounted to short and full brim hardhats, PRO-AIR(TM) ACAIR3000(TM) provides forced ambient air throughout headwear to keep workers cool. Microprocessor-controlled unit, powered by rechargeable batteries, offers automatic and manual functions. Also available, ACAIR2000(TM) is designed for arc flash hood applications. It provides continuous air supply to worker while reducing hazardous effects of shield fogging. Rechargeable batteries offer 3 hr of continuous operation per charge.
|
 Temperature Controller works with fluid dispensing systems.Sealant Equipment & Engineering, Inc.
Plymouth, MI 48170-0965
Aug 17, 2007
Peltier series Thermoelectric Temperature Controller combines Peltier thermoelectric device, temperature sensor, and temperature control mounted to manifold where fluid passes through to be heated, maintained, or cooled. Mounted in-line or on fluid dispensing equipment, product uses Peltier-Seebeck effect to directly convert electrical voltage to thermal differentials and heat or cool fluid materials to temperature set point. Accessories are available.
|
Chilling/Heating Dry Baths feature 5-program memory.Torrey Pines Scientific, Inc.
San Marcos, CA 92069
Aug 16, 2007
Peltier-driven and fully programmable, EchoTherm(TM) IC35 Series stores 5 programs in memory - with 10 steps per program - for instant recall and use. Each program can be made to repeat automatically from 1-99 times. Heavy-duty dry bath models IC35 (-10 to +100°C) and IC35XT (-20 to +100°C) can freeze, chill, or heat samples in variety of sample blocks that hold 0.5-50 ml centrifuge tubes, test tubes, vials, assay plates, and round-bottom flasks. Each measures measure 8.5 x 10 x 4 in.
|
 Blast Chiller is designed for small, low-volume kitchens.ITW
Glenview, IL 60025
Jul 26, 2007
Model FXBC10 has 10 kg capacity and can blast chill product from 70ºC to 3ºC within 90 min to maintain food quality and ensure HACCP food safety law compliance. Chiller enables left-over food from hot servery counter to be quickly and safely chilled for later use with complete confidence in its quality and safety. Suited for restaurateurs, hoteliers, and publicans, it also aids in advance food preparation by chilling larger batches for later use.
|
Rack Enclosure features integrated cooling capabilities.Emerson Network Power
St. Louis, MO 63136
Jul 16, 2007
Suited for small and mid-size data centers, Liebert XDK-W features nominal rating of 25 kW. Closed architecture solution utilizes air circulation internal to enclosure that is completely sealed from room air and environmental conditions. Server heat load is absorbed by rack's integrated cold water system through air-to-water heat exchanger in bottom of rack, while coolant distribution unit maintains fluid temperature above actual dew point to prevent condensation.
|
Vortex Tubes are suited for high-temperature applications.EXAIR Corporation
Cincinnati, OH 45249-1621
Jul 10, 2007
High Temperature Vortex Tubes convert ordinary supply of compressed air into one hot stream and one cold stream for spot cooling applications in environments up to 392°F. Compressed air is sole source of power, eliminating use of chemicals and refrigerants, and cold air temperatures are adjustable from -50°F to ambient. With cooling capacities of 135-10,200 BTU/hr, stainless steel tubes have no moving parts and offer total airflow of 2-150 scfm @ 100 psig inlet air pressure.
|
 Thermoelectric Cooler seamlessly embeds into application.Nextreme Thermal Solutions
Research Triangle Park, NC 27709-3981
Jul 09, 2007
Featuring 0.3 x 0.3 x 0.1 mm footprint, thin film eTEC(TM) addresses thermal management needs of electronics, photonics, biotech, and defense/aerospace industries. Solid state unit features millisecond response time, rapidly cooling or heating to maintain precise temperature. Operating by Peltier effect, device pumps max heat flux of 150 W/cm² with some designs delivering as much as 400 W/cm². Input power can be dynamically controlled to provide active cooling.
|
 Air Conditioning System provides spot cooling for workers.Aqua Products Co., Inc.
Newberry, SC 29108
Jun 20, 2007
Hydro-Star Spot Cooling System utilizes Superflex fittings, which adjust to let individual employees determine direction of cool air flow. Comprised of Glycol Chiller (Model DCP) and commercial, high-pressure, water-cooled air handler, system provides stream of cool, dry air exclusively to each employee at their work station via 3 in. air line. System can also take 100% outside air, cool by 15 to 25°F, and dehumidify it in one pass.
|
PCU and Battery Cooling System suit hybrid vehicles.DENSO Corp.
Aichi 448-8661 Japan
Jun 19, 2007
Including boost converter that raises main battery voltage (288 V) up to maximum system voltage (650 V), Power control unit has 2 inverters to convert dc into ac for main traction motors. PCU can be used in hybrid vehicle systems with different output levels by changing number of stacked power devices and cooling tubes. Battery cooling system uses cooled air from cooling unit of rear air conditioning system and cabin air to cool main battery.
|
 Oil Coolers suit demanding applications.Unifin International, Inc.
London, ON N6A4P4
Jun 12, 2007
Pre-engineered to meet requirements of specific applications, flexible ForZair(TM) Transformer Oil Coolers come in 50 and 60 Hz versions of forced oil-to-forced air, natural convection oil-to-water, and forced oil-to-water models. They feature mono-aluminum extruded fin-tubes and plate fin technology for optimal heat transfer efficiency. Hinged fan panels design facilitates opening of cooler and pressure-washing fin surface to maintain performance of cooler and transformer.
|
 Temperature Forcing System offers -90 to 200°C range.Thermonics Inc.
Santa Clara, CA 95054
May 11, 2007
With airflow rate of 20 cfm, Model T-2500HFE is designed to accurately control temperatures of high power electronic components. It can control device temperatures with power consumption up to 140 W to within ±1°C. In addition, system can be used to test multiple units in parallel, and to cool large test chambers such as those used in PCB testing.
|
 Transformer Oil Coolers range from 125-750 kW.Unifin International, Inc.
London, ON N6A4P4
May 10, 2007
Available in standard sizes and configurable designs, ForZair(TM) Mobile Coolers utilize mono-aluminum extruded fin-tubes and plate fin technology for optimal heat transfer. Units handle oil flows of 200-650 gpm and top oil rise of 35-63°C. Featuring galvanized finish as standard, coolers are also available with 2-part epoxy paint option for chemically aggressive environments or 3-part system for marine environments.
|
Cabinet Cooler uses compressed air.EXAIR Corporation
Cincinnati, OH 45249-1621
May 10, 2007
Dual Cabinet Cooler incorporates vortex tube to circulate 20°F compressed air without refrigerants and maintains NEMA 12, 4 or 4X rating of enclosure. Drain filter separator keeps moisture out of enclosure to protect sensitive electronics from harsh environments. Dual Cabinet Cooler is UL listed, accurate at ±2°F of set temperature, and available in 4,000, 4,800, and 5,600 Btu/hr capacities.
|
Truck Air Conditioning System works while engine is off.Behr GmbH & Co. KG
Stuttgart 70469 Germany
May 09, 2007
Integrating with OEM auxiliary HVAC systems, ducts, and controls, NIA/C No-Idle System provides air conditioning to heavy-duty truck cabins while engine is turned off. It features externally mounted compressor/condenser for quiet sleeping environment, maintains comfortable cabin temperatures day or night, and offers one-button starting. Compliant with no-idle regulations, system cuts fuel consumption, engine wear, and emissions.
|
(Showing headlines 41 - 60) 1 2 3 4 5 6 7 8 9 10 11 12
|
|
|