Fan Controller regulates RPM according to real-time demand.Degree Controls Inc.
Milford, NH 03055
Oct 05, 2009
To ensure required linear air velocity is maintained despite external influences, C-600 controls and modulates fan RPM based on real-time air velocity and/or temperature measurements. User-programmable air velocity and temperature set points are leveraged to increase or decrease fan RPM, and I²C- or UART-based communication to host system can relay real-time information. If cooling fan is unable to generate desired flow requirement, controller initiates low-flow alarm to system.
|
Digital Controller controls air curtain operation.Berner International Corp.
New Castle, PA 16101
Sep 14, 2009
In addition to temperature/fan speed control, Intelliswitch 2(TM) provides programming and diagnostics capabilities. All functions are supported by microprocessor that features 16 MHz clock speed, 64 kb program memory, 4 kb RAM, and analog/digital conversion. Operating switch, timer/delay, thermostat, and 10-speed fan control are all built-in. Measuring 4 3/8 x 4 1/8 in., RoHS-compliant controller operates with Maxair and Zephyr air curtain models.
|
Management Solution conserves energy in HVAC systems.Rockwell Automation
Milwaukee, WI 53204
Sep 04, 2009
Without requiring changes to existing mechanical systems or controls, FanMaster energy saving package lets users convert constant volume HVAC air handler to variable air flow. System is comprised of CO2 transmitter, damper blade position indicator, 2 duct insertion temperature transmitters, controller, and touchscreen operator interface. Unit controls PowerFlex 400 AC drive and conserves energy by enabling users to adjust fan speed.
|
Water Temperature Control offers capacities up to 24 kW.Mokon
Buffalo, NY 14207
Aug 07, 2009
Available in standard heating capacities from 3-24 kW, Hydrotherm Circulating Water Temperature Control System offers ratings from 208-600 V, pump sizes from ½-3 hp, and flow rates from 15-60 gpm. System features microprocessor-based controller, hybrid-epoxy powder coated cabinetry with 14 gauge base, 16 gauge electrical enclosure, and stainless steel components for wetted surfaces, including stainless steel pump, heater canister, and pump suction manifold.
|
 Fan Speed Control targets condenser applications.Johnson Controls, Inc.
Milwaukee, WI 53201
Aug 05, 2009
Housed in weather-resistant enclosure, Model P266 is designed for single-phase Permanent Split Capacitor motors used in variety of outdoor low-ambient refrigeration and air conditioning condenser applications. Control includes stainless steel electronic pressure transducer that prevents refrigerant leaks, as well as field adjustable speed, pressures, start voltage, and minimum speed/cutoff.
|
HVAC Control reduces system complexity in vehicles.Visteon
Dearborn, MI 48126
Jul 29, 2009
Intended for automotive HVAC controls, pulse count system enables vehicle manufacturers to use non-feedback DC motor actuators. Position of actuator in HVAC system is determined by reading pulses from motor, and climate control algorithms control DC motor actuators via power and ground wires only. Offered as ASIC with embedded inductor-based sense element, system is self-calibrating and monitors key operating parameters to maintain optimal performance.
|
 Hybrid Control regulates condensing/non-condensing boilers.Heat-Timer Corporation
Fairfield, NJ 07004
May 01, 2009
Mini-MOD-CNC automatically mixes and matches non-condensing boiler operation and condensing boiler operation to optimize efficiency of combined (hybrid) system. It also allows for mixed control of modulating and staging boilers, since condensing boilers typically have modulating burners and non-condensing boilers typically have staging or on/off burners. Control automatically switches to high mass boilers when building heat requirements approach design loads.
|
 Fan Drives and Controller reduce fuel consumption and noise.Horton, Inc.
Roseville, MN 55113
Apr 22, 2009
Designed to aid in cooling of hotter-running, reduced-emission engines, VMaster® and Stratis(TM) Di Viscous Fan Drive and Controller systems offer precision, variable-speed performance. Endurance-tested VMaster Di responds rapidly to changing cooling requirements and offers optimized torque transmission and fan idling speed. Stratis Viscous Fan Drives feature reservoir, actuator, and valve system that optimizes response time to increase airflow and cooling.
|
 Dual-Function Fan Control replaces thermal time delays.Vtronix LLC
Weston, FL 33326
Mar 27, 2009
Measuring 2½ x 2½ in., single-speed R60B provides control of line voltage fan motor used in heat pumps, air-conditioning, and forced air systems. This electronic fan control board, powered by 24 Vac input, accepts 24 Vac fan signal from thermostat. Fixed 1 sec fan ON delay eliminates thermostat bounce, while fixed 45 sec post fan OFF delay increases efficiency by purging air ducts of residual air. Secure screw-in terminals are provided for R, C, and G connections.
|
 Head Pressure Control suits humidity-sensitive environments.ICM Controls
Syracuse, NY 13212
Mar 05, 2009
With support for both dual pressure or temperature inputs, ICM333 operates as pressure or temperature-sensitive motor fan speed control, regulating head pressure by varying amount of airflow through condenser. Unit is compatible with single-phase systems operating at 120-480 Vac. Other features included are integral heat pump bypass circuitry, allowing for electronic bypass of speed control, and tamper-proof dials for adjusting temperature/pressure set points.
|
Condensing Boiler Blower/Control ensures constant combustion.EBM - Papst, Inc.
Farmington, CT 06034
Mar 05, 2009
Consisting of intelligent ebm-papst blower and control unit, LambdaConstant System for condensing boiler systems adjusts automatically to optimum combustion, even when variable gas types are present. Burner temperature control is independent of gas quality and burner load is independent of ambient conditions. With modulation range of 1:10, system meets variety of output requirements, from low heat output to full power output for hot water supply.
|
Air Conditioner Controller is RoHS-compliant.MovinCool/Denso Sales of California, Inc.
Long Beach, CA 90810-1868
Mar 03, 2009
Available for OfficePro® and Classic Plus spot air conditioners, controller features LCD that displays current time, day of week, room temperature, set temperature, fan hi/lo mode, and cool on/off mode. Users can track total operating time and lock control panel to prevent unauthorized personnel from changing settings. If condensate tank becomes full, water-level alert system turns air conditioner off and sends electrical output signal to activate alarm or other warning device.
|
HVAC Bypass Controller minimizes electrical system harmonics.Mitsubishi Electric Automation, Div.
Vernon Hills, IL 60061
Feb 04, 2009
Suited for NEMA 12 ventilated enclosures, Pow-R-Gate HVAC bypass controller utilizes 18-pulse variable-frequency technology and meets IEEE 519-192 requirements at input terminals. It is rated up to 800 hp at 460 V. Multifunction programming and display unit, with average setup of 8 parameters, allows selection of manual/automatic bypass. Unit includes 3 contactor bypass configuration, PID control, and disconnect as well as RS485 and Modbus® RTU.
|
 Temperature Controller has easy-to-read dual display.Omega Engineering, Inc.
Stamford, CT 06907
Jan 12, 2009
Including ON/OFF, PID, auto-tuning or manual tuning control functions, CN730 series of ¼ DIN temperature controllers suit applications in water, automotive, and food processing industries. They accept variety of thermocouple and RTD inputs. Process value and set-point value are simultaneously displayed with process value in red and setpoint in green. Accuracy is ±0.25% of span, ±1 least significant digit, and resolution is 1°.
|
 Dimmers/Fan Speed Controls do not de-rate when ganged.Pass & Seymour/Legrand
Syracuse, NY 13221
Oct 31, 2008
LS Series Slide Dual Dimmer features two 300 W, single-pole, slide-to-off dimmers and installs in one gang box. LS Series Decorator Preset Dimmer with Independent Switch comes with single-pole, 3-way preset dimmer and single-pole, 3-way switch functions. LS Series Dual Fan Speed/Dimmer combines single-pole, 3-way preset dimmer and single-pole, 3-way preset de-hummer fan speed control. All controls support optional locator light via installation of Trade Master Snap-In Light Module.
|
 Dimmer controls 120 V 2-wire dimming ballasts.Pass & Seymour/Legrand
Syracuse, NY 13221
Oct 28, 2008
Able to operate single pole or 3-way circuits, Harmony Dimmer includes captive paddle on/off air-gap switch, preset dimmer slide, green LED locator light, and EMI/RFI reduction circuitry. It can handle up to 8 A total load in single and 2-gang installations, and features adjustable low-end trim pot and power failure memory. Available in matte finish, product comes in white, ivory, light almond, black, and brown.
|
 A/C Controller suits users with fluctuating heat loads.Vtronix LLC
Weston, FL 33326
Sep 25, 2008
Designed to operate 2 independent air conditioners based on temperature/run-time, Model W110 Lead-Lag Controller controls each A/C for specified change-over time setting. With lead-lag controller, high temperature sensor, and humidistat, it monitors abnormalities by detecting/showing alarm signals such as fire alarm and air overload. Micro-processor based unit brings second air conditioner on-line as heat load increases and shuts it down as demand for additional cooling diminishes.
|
Building Controls deliver flexibility for integrators.Siemens Building Technologies, Inc.
Buffalo Grove, IL 60089
Sep 10, 2008
Featuring open architecture based on BACnet or LonTalk protocols, TALON® building automation controls offer integration capabilities and set of tools to aid in design, installation, and commissioning tasks. Products help meet demands for reliable access to flexible control technologies and relevant technical information. Integration drivers enable precise HVAC system management; tightly integrated control of security, fire, and lighting systems; and building management capabilities.
|
 Digital Switch controls water temperature.Dwyer Instruments, Inc.
Michigan City, IN 46361 0373
Sep 05, 2008
Series TSWB Digital Temperature Switch has high and low set point for controlling water temperature; low set point can either be manually or automatically reset. Control also has conductivity level probe input, which supplies 12 Vac to probe to check for low water condition. Unit includes 3 relay outputs which can be assigned in field to high water temperature set point, low water temperature set point, or low water level input.
|
CO2-Based DCV System promotes building energy efficiency.Cemtrex Inc.
Farmingdale, NY 11735
Aug 25, 2008
Green-DCV (Demand Controlled Ventilation) system acts as indoor air quality system coupled with energy efficiency system by monitoring fluctuating occupancy levels inside all types of commercial buildings and controlling HVAC systems for optimum performance. Components include centralized monitoring and analyzer station, fast loop air routers, controls for exit dampers and variable air volume boxes, as well as Web-enabled interface to Building Management System.
|
(Showing headlines 1 - 20) more ....
|
Latest Products in the News |
Hench Control Inc. - September 3, 2009 Hench Control's Impact on Sustainability for Industrial Refrigeration
Leviton Manufacturing Co., Inc. - August 4, 2006 Leviton's Vizia Collection Named Among Electronic House Magazine's Top Products of the Year
More Products in the News...
|
|
|
|
 |
ThomasNet News Advertisers
|
 |
|