|
|
|
|
|
HVAC
(Showing headlines 981 - 1000) << 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 ...
|
 Temperature Controller works with fluid dispensing systems.Sealant Equipment & Engineering, Inc.
Plymouth, MI 48170-0965
Aug 17, 2007
Peltier series Thermoelectric Temperature Controller combines Peltier thermoelectric device, temperature sensor, and temperature control mounted to manifold where fluid passes through to be heated, maintained, or cooled. Mounted in-line or on fluid dispensing equipment, product uses Peltier-Seebeck effect to directly convert electrical voltage to thermal differentials and heat or cool fluid materials to temperature set point. Accessories are available.
|
 Fiber Optic Data Logger Thermometer promotes freedom of use.Omega Engineering, Inc.
Stamford, CT 06907
Aug 17, 2007
Powered by 4 standard alkaline AA or rechargeable batteries that provide at least 5 hr of continuous use, HHTFO-101 lets operators move about freely in order to measure temperatures at various critical sensing points. Single-channel instrument, equipped with LCD and RS232 com link, is CE-compliant and available with optional Windows software. Suited for multiple applications, this data logger comes with universal charger and 4 AA NiMH batteries.
|
 Wall-mounted heating boiler is Energy Star qualified.Lochinvar Corp.
Lebanon, TN 37090
Aug 16, 2007
KNIGHT wall-mounted fully modulating condensing heating boiler features 5:1 turndown burner and adjusts heat output according to demand. Boiler offers an efficiency rating of at least 93%, and permits intake with venting running up to 40 feet using 2 in. pipe. Also features Smart System operating control with user-friendly interface, outdoor reset with sensor, three pump control, night setback, and password security. Optional software enables recording, tracking, and data analyzation.
|
Chilling/Heating Dry Baths feature 5-program memory.Torrey Pines Scientific, Inc.
Carlsbad, CA 92010
Aug 16, 2007
Peltier-driven and fully programmable, EchoTherm(TM) IC35 Series stores 5 programs in memory - with 10 steps per program - for instant recall and use. Each program can be made to repeat automatically from 1-99 times. Heavy-duty dry bath models IC35 (-10 to +100°C) and IC35XT (-20 to +100°C) can freeze, chill, or heat samples in variety of sample blocks that hold 0.5-50 ml centrifuge tubes, test tubes, vials, assay plates, and round-bottom flasks. Each measures measure 8.5 x 10 x 4 in.
|
 Fume Hoods pass 3-stage ANSI/ASHRAE test.Lab Fabricators Co.
Cleveland, OH 44103
Aug 14, 2007
Featuring redesigned air plenum and directional air vanes, 90% Energy Efficient Fume Hoods create uniform, low-velocity air curtain that contains and carries away fumes inside hood to rear exhaust port. Supplemental air is not forced down and on to hood operator. Combined supplemental air and exhaust air form push-pull effect that requires minimal energy power consumption of conditioned room air while offering maximum protection to lab personnel from toxic fumes.
|
 Filtration Assembly resists concrete dust buildup.Ruwac Industrial Vacuums
Holyoke, MA 01041
Aug 08, 2007
MicroClean filtration system for portable vacuum line features manual quick release assembly that drops accumulated concrete dust from filter. Design keeps filter integrity intact to ensure dust-free operation and dustless environments for concrete workers. Available as upgrade for any existing portable machine for concrete dust recovery, dry-material filter assembly is included with all vacuums.
|
 Tube Axial Fan offers direct drive capacity to 29,000 cfm.Continental Fan Mfg. Inc.
Buffalo, NY 14215
Aug 06, 2007
Available in diameters from 12-42 in., ADD Tube Axial Fan is constructed with heavy-duty, welded steel housing and angle ring flanges, with spark-resistant, cast aluminum airfoil axial impeller. Unit is powered by TEFC industrial duty motor and includes externally mounted and wired junction box. Mountable in ductwork in any position, fan is suited for process ventilation, in-line duct boosters, general ventilation, and fumes, dust, or smoke removal.
|
 Sealed Combustion Boiler has spark pilot ignition system.RBI Water Heaters
Westfield, MA 01085
Aug 02, 2007
LCD Dominator(TM) Series uses sealed combustion chamber, alloy burners, and multi-speed blowers for efficient staging. Sealed combustion chamber provides flexibility of using outside air or mechanical room air for combustion. Available as indoor/outdoor units, jacketed boilers feature construction that promotes ease of serviceability. Series includes 12 models with range of 225-2,300 MBH.
|
 Blast Chiller is designed for small, low-volume kitchens.ITW
Glenview, IL 60025
Jul 26, 2007
Model FXBC10 has 10 kg capacity and can blast chill product from 70ºC to 3ºC within 90 min to maintain food quality and ensure HACCP food safety law compliance. Chiller enables left-over food from hot servery counter to be quickly and safely chilled for later use with complete confidence in its quality and safety. Suited for restaurateurs, hoteliers, and publicans, it also aids in advance food preparation by chilling larger batches for later use.
|
 Blower Systems include 15 ft duct and polyester carry bag.Allegro Industries
Garden Grove, CA 92841-1410
Jul 20, 2007
Featuring portable design with carry handles and shoulder strap attachment, Air Bag Blower Systems are available with 8 or 12 in. metal blower, each with 9-blade fan and steel construction. Air Bag 8 features ¼ hp motor and delivers up to 700 cfm, while Air Bag 12 is equipped with ½ hp motor and produces 1,800 cfm. Both units contain single-ply vinyl/polyester PVC coated ducting. Zippered ends allow blower use without removing blower from carry bag.
|
Reaction Calorimeter enables online heat data measurement.Mettler Toledo, Inc.
Columbus, OH 43240
Jul 19, 2007
Offering at-a-glance characterization, RTCal(TM) provides process R&D chemists and engineers with tool that can be used alone or together with heat flow method to provide additional data. Measurement is based on built-in heat flux sensor and independent of properties or behavior of reaction mass. While unit does not require any calibration, it lets user make adjustments to actual chemistry and optimization of process parameters online.
|
Rack Enclosure features integrated cooling capabilities.Emerson Network Power
St. Louis, MO 63136
Jul 16, 2007
Suited for small and mid-size data centers, Liebert XDK-W features nominal rating of 25 kW. Closed architecture solution utilizes air circulation internal to enclosure that is completely sealed from room air and environmental conditions. Server heat load is absorbed by rack's integrated cold water system through air-to-water heat exchanger in bottom of rack, while coolant distribution unit maintains fluid temperature above actual dew point to prevent condensation.
|
Ceiling Fans move air more efficiently.Big Ass Fans
Lexington, KY 40575
Jul 12, 2007
PowerfoilPlus High-Volume/Low-Speed (HVLS) ceiling fans utilize hybrid airfoil technology that redirects airflow away from floor. Upturned length at the end of the airfoil pushes air out at an angle, creating more widespread air pattern capable of passing over obstructions. provide efficient delivery of air to occupants.
|
Dust Collector offers downdraft velocity of up to 100 fpm.United Air Specialists Inc.
Cincinnati, OH 45242 2832
Jul 11, 2007
With air volumes up to 2,500 cfm, Model SDB captures smoke, dust, and powders resulting from operations such as grinding, polishing, hand sanding, and dry buffing. System features 80 x 55 in. grated work surface that can accommodate loads up to 75 lb/sq-ft. It automatically self-cleans when pulses of compressed air dislodge dust from filters upon shutdown. By drawing particles and contaminants away from worker's breathing zone, SDB help companies comply with OSHA regulations.
|
Vortex Tubes are suited for high-temperature applications.EXAIR Corporation
Cincinnati, OH 45249-1621
Jul 10, 2007
High Temperature Vortex Tubes convert ordinary supply of compressed air into one hot stream and one cold stream for spot cooling applications in environments up to 392°F. Compressed air is sole source of power, eliminating use of chemicals and refrigerants, and cold air temperatures are adjustable from -50°F to ambient. With cooling capacities of 135-10,200 BTU/hr, stainless steel tubes have no moving parts and offer total airflow of 2-150 scfm @ 100 psig inlet air pressure.
|
Thermoelectric Cooler seamlessly embeds into application.Nextreme Thermal Solutions
Durham, NC 27003
Jul 09, 2007
Featuring 0.3 x 0.3 x 0.1 mm footprint, thin film eTEC(TM) addresses thermal management needs of electronics, photonics, biotech, and defense/aerospace industries. Solid state unit features millisecond response time, rapidly cooling or heating to maintain precise temperature. Operating by Peltier effect, device pumps max heat flux of 150 W/cm² with some designs delivering as much as 400 W/cm². Input power can be dynamically controlled to provide active cooling.
|
Temperature Sensor installs in any thermowell.Moore Industries International, Inc.
North Hills, CA 91343
Jul 09, 2007
Suited for new and retrofit applications, WORM Flexible Sensor replaces restrictive straight sensor probes. Unit bends around and through top or face of thermowell enclosure and snaps into place without removal of enclosure, conduit, connection head, or any assembly components. Immune from external temperature effects, WORM is available with 100 and 1,000 W platinum, copper, and nickel RTDs, as well as J- and K-type thermocouples.
|
 Process Air Heater heats nitrogen/inert gas up to 1,400°F.Osram Sylvania, Inc.
Danvers, MA 01923
Jul 03, 2007
Featuring digital display temperature control, SKORPION(TM) Process Air Heater provides full closed-loop PID temperature regulation with ±2° accuracy. Device includes serpentine coil design for maximum heat transfer efficiency, blower motor, air intake, and intelligent over-temperature sensing system. All-metal air source ensures operation in dusty environments, and unit also features adjustable air damper for flow control.
|
 Monolithic Sensor measures humidity and temperature.E+E Elektronik GmbH
Engerwitzdorf A-4209 Austria
Jun 26, 2007
Featuring temperature sensor and capacitive humidity sensor located on same glass substrate, HMC01 takes stable measurements in demanding industrial applications with continuous high humidity - even those with risk of condensation. Unit can be operated in controlled heating mode to prevent high humidity drift and expel foreign molecules. Local sensor temperature can be determined exactly, which allows for accurate calculation of dew point temperature.
|
Fume Extraction System offers range of operating modes.OK International
Garden Grove, CA 92841
Jun 22, 2007
Featuring brushless motor technology that eliminates wearout of motor parts, Model BVX-200 Fume Extraction System delivers high torque and power for improved extraction performance and elimination of dust produced by brush friction. Features include low electrical noise and RF interference and elimination of sparking between brushes and commutator rings.
|
(Showing headlines 981 - 1000) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105
|
|
|