HVAC
(Showing headlines 521 - 540) << 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 ...
|
 Chilling Station features centralized, modular design.Frigel
East Dundee, IL 600118
Jun 11, 2009
Incorporating Turbocor variable speed centrifugal technology, Ecoflex is supplied cool water from Ecodry System and can be fully integrated into processor's cooling system through intelligent microprocessor controller. System's compressor features oil-free magnetic bearings and soft start to conserve energy. Suited for injection molding applications where individual press side units are not required, Ecoflex units can be linked together as higher capacities are needed.
|
 Condenser Fan features fully reversible double flange design.Continental Fan Mfg. Inc.
Buffalo, NY 14215
Jun 11, 2009
Available in diameters from 12-42 in. and capacities ranging to 34,000 cfm, compact AFK Flange fan is made of heavy gauge steel with baked polyester coating and has airfoil adjustable pitch cast aluminum impeller. It features advanced computer selection program and can be duct mounted if needed. Suited for OEM applications or replacement fans, unit is available with GRP (polypropylene) blades and can be built for supply or exhaust configurations.
|
 Infrared Temperature Sensor suits autosports applications.Variohm Components
Towcester Northamp NN12 6HP United Kingdom
Jun 05, 2009
With 150, 200, and 800ºC temperature ranges, ETIS series is designed for demanding tire, brake, and exhaust temperature measurement in autosports. It has 1,000 G shock rating and is packaged in lightweight aluminum housing measuring 20 x 18 x 12 mm and weighing 26 g. Available with front facing M3 fixing holes and 1 m long shielded leads, unit operates in ambient temperatures between 0-120ºC with 30-70 mm measurement stand-off distance and target area of approximately 20 mm dia.
|
Solar Panel delivers conversion efficiency of 19.3%.SunPower Corp.
San Jose, CA 95134
Jun 04, 2009
Designed for installation in residential and commercial applications, SunPower® 315 Solar Panel features anti-reflective coated glass that optimizes capture of diffuse off-angle light and subsequently maximizes energy generation. This 96-cell, 315 W panel incorporates all-back contact solar cells to maximize energy production, resulting in fewer panels per rooftop while also offering aesthetically pleasing appearance.
|
 Abort Gate increases dust collection equipment safety.Imperial Systems, Inc.
Jackson Center, PA 16133
Jun 03, 2009
Featuring heavy-duty, fully welded steel construction and OSHA safety yellow paint, High Speed Abort Gate can be located prior to inlet of dust collection system to prevent ingress of flame or burning ember. It can be actuated by leak detection or broken bag sensors and may also be placed on return air side of dust collector to redirect contaminated air to safe location. Other features include gate accelerating springs; fail-safe electro-magnets; steel gate seals; and limit switches.
|
 Portable Cooling System cools up to 1,000 sq ft.Port-A-Cool
Center, TX 75935
Jun 02, 2009
Port-A-Cool® JetStream 1600 portable evaporative cooling unit is suited for mechanic's bays, work shops, small work areas, and patios. It includes louvers to direct airflow, built-in cord wrap, and water fill options utilizing built-in reservoir or garden hose. Using tap water and 115 V of electricity, device lowers temperatures by 15-25°F. Its 1-piece housing eliminates leaks and rust while KUUL® Pads cooling media maximize operational capabilities.
|
 Portable Chiller utilizes EPA-compliant R410a refrigerant.Sterling
New Berlin, WI 53151
Jun 02, 2009
Available in air- and water-cooled versions, GP Series features leaving coolant temperature range of 20-80°F and electronic modulating capacity control that maintains temperature to within 0.1°F. Electronic sensors monitor leaving/entering fluid temperatures, compressor suction/discharge pressure, condenser inlet temperature, pump pressure, and tank level. LCD shows operating status, set point, and to-process temperature on multiple screens. R410a refrigerant is chlorine-free.
|
 Inductive Sensors can operate in environments up to 230°C.Automation Systems Interconnect Inc.
Mechanicsburg, PA 17055
Jun 02, 2009
Featuring sizes ranging from miniscule 4-30 mm, inductive sensors are available in short-housing models with option of square or rectangular shape. They offer choice of NAMUR, AC/DC, NPN or PNP output, NO or NC output, and programmable output, and come with 2, 3, or 4-wire, connector or cable, with 360° LED indicator. Choice between shielded or unshielded sensors is available for high-heat and standard applications.
|
 Medical Ventilator is designed for mice.Harvard Apparatus, Inc.
Holliston, MA 01746 1371
Jun 01, 2009
Suitable for any animal with tidal volumes of 30-350 µL and respiratory rates of 60-400 breaths/min, MiniVent features rod clamp that allows it to be positioned directly next to animal. Ventilator employs valveless rotary plunger that eliminates clogging during ventilation cycle. Inspiration and expiration is controlled by synchronized forward and rotating movement of cylinder and plunger. Compact and lightweight unit reduces tidal volume error due to system compliance to 3 µL.
|
 Condensing Boilers have replaceable SS flexible tubes.Bryan Steam LLC
Peru, IN 46970
Jun 01, 2009
Triple-Flex(TM) condensing flexible water tube boilers fire at 3,000 MBH input, with sub 30 ppm NOx levels, utilizing hybrid metal fiber 5:1 turndown burner and SOLA hydronic safety controls and interface systems. Other features include variable speed combustion air blower and removable access panels making boiler interior accessible for service and inspection. Triple-Flex(TM) boilers deliver operating efficiencies of 99% in new buildings designed for condensing boiler conditions.
|
 Cooling Enclosures suit network closet, server room areas.American Power Conversion
West Kingston, RI 02892
May 28, 2009
Featuring up to 7 kW of cooling capacity, 600 mm wide rack enclosure, as well as front and rear containment options, InRow® SC Systems can be deployed as fully contained IT environment or partially contained system that can be added as retrofit. Self-contained solutions monitor and actively adjust cooling capacity to ensure proper server inlet temperatures. Intelligent and manageable components make the system network-enabled and self-monitoring.
|
 Vane-Axial DC Fans suit high static pressure applications.Knight Electronics
Dallas, TX 75243
May 28, 2009
Available in 12, 24, and 48 Vdc configurations and 120 x 38, 92 x 38, 80 x 38, and 60 x 38 mm frame sizes, VA Series Fans feature dual ball bearing system with brushless DC, auto restart, polarity-protected motor. Units maximize airflow even in nearly sealed enclosures, making them suited for networking and telecommunications equipment, industrial electronic cabinets, and medical imaging equipment. PWM, tachometer, alarm, and thermal control options are available.
|
Temperature Measurement System has multi-sensor capability.SenGenuity, a division of Vectron International
Hudson, NH 03051
May 27, 2009
Delivering performance for real-time, in-process temperature sensing applications, wireless TempTrackr(TM) allows for parallel interrogation of several independent passive temperature sensors. SAW-based sensors maintain unique identification within system architecture and require no power source. Along with 4 dipole antennas and wireless interrogator, TempTrackr Multi-Sensor kit includes 4 sensors capable of reading temperatures between 0 and +120°C from max distance of 70 in.
|
 Sensors monitor hydraulic systems aboard aircraft.Kavlico
Moorpark, CA 93021
May 22, 2009
Housed in stainless steel with MIL-38999 style connector, Combined Pressure and Temperature Sensors are available in pressure ranges of 0-500 through 0-10,000 psia with temperature range of -55 to +125°C and accuracy of ±1.0% FSO. Operating on 5-15 Vdc, sensors can be configured with amplified 0.5-4.5 Vdc or non-amplified 50-100 mV at 10 Vdc excitation output. Sensors can withstand harsh environments, and are suited for active control systems, system status, and health monitoring.
|
 Fume Extractor removes smoke, fumes, and heat at source.Vent-A-Fume, A Div. of Vent-A-Kiln Corp.
Buffalo, NY 14207
May 22, 2009
Available in 4 models with fume extraction capacities from 400-1,150 cfm, Place-A-Vent is designed for removing and ventilating fumes produced by welding, brazing, soldering, laser cutting, plasma cutting, and similar operations. It employs negative pressure system that exhausts all fumes quickly to outside or into existing ductwork. Accessories include flexible gooseneck hood support arms and customized systems are also available.
|
Environmental System prevents ventilation air contamination.Kathabar Dehumidification Systems Inc.
Somerset, NJ 08873
May 22, 2009
Secure Environmental System(TM) (SES) ecologically safe technology which prevents contamination of building ventilation air from outside sources. It also exchanges temperature and humidity between airstreams with bactericidal and virucidal desiccant transfer solution, which provides energy recovery and removes airborne contaminants. Ventilation and exhaust air are handled by separate units; no cross leakage or microbiological cross-contamination of exhaust air to ventilation air can occur.
|
 Injection Systems help mitigate multi-pollutant emissions.Nol-Tec Systems, Inc.
Lino Lakes, MN 55014
May 20, 2009
Using dilute-phase positive-pressure pneumatic conveying technology, Sorb-N-Ject(TM) Technology injection systems continuously transfer dry bulk sorbent material from storage silos to injection ports on boiler flue gas ducts, which reacts with multi-pollutants in flue gas to reduce emissions. Fluidizing bin bottom installed on each silo prevents stored material from rat holing, bridging, or arching. System includes loss-in-weight feeder hopper with reverse jet pulse dust filter system.
|
Cable Kit simplifies floor warming coverage.Easy Heat Inc.
East Granby, CT 06026
May 18, 2009
Warm Tiles® DFT 120 V floor warming cable kit allows contractors to install full floor warming coverage simply by lacing free form cable on floor wherever heated area is required. Cables can be used over variety of substrates including plywood, backer board, and concrete, and are placed 3 in. apart in typical room above heated area, and 1.5 in. apart for room above unheated area, on concrete slabs, or in high heat loss room. Kits are available for heating areas from 11-108 sq ft.
|
 Vehicle Air Conditioning Condenser Unit 24 x 18 in. footprint.Visionaire, Inc.
Grand Prairie, TX 75051
May 15, 2009
With internal hydraulic compressor drive that requires flow of 8 gpm at 1,200-1500 psi, Model 3110 condenser unit for work equipment can be paired with wide variety of in-cab air conditioners and heater components. It is rated at 24,000 BTU/hr and features formed and welded steel construction, powder coating, and fully hydraulic component isolation. Optional equipment includes diesel fired coolant heater and variety of cab air filtration and pressurization systems.
|
 Industrial Steam Boilers suit laboratory applications.SUSSMAN Electric Boilers, a Div. of Sussman-Automatic Corp.
Long Island City, NY 11101
May 14, 2009
Designed for industrial marketplace, Model ES electrically heated saturated steam boiler suits laboratory, hospital, industrial plant, pilot plant, as well as food and chemical processing applications requiring steam from 0-100 psig. It features automatic pressure and liquid level controllers as well as ASME Code pressure vessel and safety valve. Installation only requires water feed connection and electrical hook-up.
|
(Showing headlines 521 - 540) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102
|
|
|