HVAC

HVAC, Optics & Photonics

Cable Blowing Machine installs micro fiber cable.

June 24, 2015

Engineered to install micro fiber cable into pre-installed 0.157–0.708 in. diameter microduct, Whisper Micro Cable Blower can place 0.078–0.334 in. diameter cable at speeds up to 260 fpm. Product features integral air valve, pressure gauge, and electronic monitoring system that provides digital read-outs of speed and distance. Operated by single person, portable Whisper is suited for both interior and exterior fiber cable placement applications. Read More

Fluid & Gas Flow Equipment, HVAC, Material Handling & Storage

Compressed Air Filters exhibit minimal pressure differential/loss.

June 23, 2015

Deep-pleat KE (KAESER Extra) aerosol filters achieve residual aerosol content of 0.01 mg/m³ and saturation differential pressure of no more than 200 mbar. Range covers 4 element grades for filtration of aerosols, dust, and oil vapors so that compressed air can be treated to suit needs of specific application in accordance with ISO 8573-1 purity classes. Suitable for pressures up to 16 bar at temperatures of up to 66°C, there are 9 model sizes for flow volumes from 21.2–501.5 cfm. Read More

HVAC, Green & Clean

HVAC Systems combine energy efficiency and comfort.

June 23, 2015

Intended for residential and light commercial markets, Champion HVAC Systems come in variety of tonnages, fuel sources, and configurations. Heating and cooling equipment is rated in accordance with AHRI Standard 210/240 and 340/360 at AHRI conditions. Product line also meets relevant ASHRAE 90.1, ENERGY STAR®, and EPACT 2005 standards. Read More

HVAC

Air Measuring Dampers provide accurate control.

June 17, 2015

To control airflow volumes to target set point, thermal dispersion-based AMD-TD series combines functionality of thermal dispersion airflow station and control damper. Vari-Green® airflow measurement probes and transmitters enable airflow measurement down to 100 fpm. While factory-supplied controllers are available with analog or BACnet MS/TP operation, optional factory-supplied controller makes series turn-key solution. There are 4 models that feature various blade styles. Read More

Controls & Controllers, HVAC, Test & Measuring Instruments, Sensors, Monitors & Transducers

Temperature Controllers has UL listing and integrated design.

June 16, 2015

UL-Listed HALO® combines multiple sensor inputs, including process temperature, limit temperature, and current sensing, to allow monitoring of multiple heaters wired in parallel. Designed for use in remote locations that may pose limited accessibility issues for maintenance personnel, unit also offers Modbus RS-485 communications, DIO, hi/low alarm output, and ramp/soak temperature profiles. Plug-and-play operation is supported with SENTINEL® Gas and Pump Line heaters. Read More

HVAC

Tankless Water Heaters feature Energy Factor up to .93.

June 16, 2015

Suited for both indoor and outdoor applications, Ultra Series RUCS/RUS75 and RUCS/RUS65 feature BTU ratings of 160,000 and 130,000, respectively. Condensing tankless units offer concentric/dual-pipe venting options and status monitor control while delivering endless supply of hot water. Heaters are suited for installations that do not require high BTUs, such as smaller single-family homes and multifamily residential projects. Read More

Sensors, Monitors & Transducers, HVAC, Test & Measuring Instruments

Wireless Sensor provides machine monitoring.

June 11, 2015

Measuring RMS velocity in in./sec or mm/sec, and temperature, Wireless Vibration and Temperature Sensor helps identify machine problems before they become too severe. Sensor is optimized to work with 1-wire serial radio devices. Operators can set vibration thresholds based on ISO 10816 standard. When threshold has been exceeded, wireless node can provide local indication, send signal to central location, and send vibration/temperature data to gateway for collection and trending. Read More

HVAC, Green & Clean

HVAC Systems target light commercial applications.

June 11, 2015

Consisting of packaged heating and cooling units, packaged heat pumps, and split systems, TempMaster® Product Line offers variety of tonnages, fuel sources, configurations, and heating/cooling varieties. Products are rigorously tested and rated in accordance with AHRI Standard 210/240 and 340/360 and meet relevant ASHRAE 90.1, ENERGY STAR, and EPACT 2005 standards. Read More

HVAC

Solution Gas Compressors handle low-volume applications.

June 10, 2015

With compression element designed for low-volume solution gas applications, Hydraulic Casing Gas (HCG) compressors do not have such common failure points as pneumatic control valves or liquid separation and handling equipment. This design eliminates any possibility of liquid lock. Also, independence of pump jack enables both pump jack and compressor to be individually managed as to maximize oil production. Capacity control system reduces and maintains casing pressure at settable level. Read More

HVAC, Test & Measuring Instruments

Active Temperature Sensors serve HVAC, building technology market.

June 5, 2015

Available with 0–10 V or 4–20 mA outputs, active temperature sensors include duct mounted types, versions for wall mounting (indoors and outdoors), strap-on version for mounting on ducts and pipes, and version with remote probe. Immersion wells with mounting spring turn duct versions into immersion sensors for temperature measurement in fluids. Factory scaling is freely selectable and can be changed by user, and external fixing holes allow device to be mounted with closed cover. Read More

Chemical Processing & Waste Management, Fluid & Gas Flow Equipment, HVAC, Green & Clean

HVAC Air Filter features energy efficient design.

June 5, 2015

Rated A+ by Eurovent, Hi-Flo F7 50+ Bag Filter is made of glass-fiber media with conical shaped pockets. Aerodynamic design prevents filter pockets from overlapping each other or coming in contact with filter housing, optimizing airflow through filter. Green thread used for stitching has been chosen for its ability to handle strong airflows. For easy identification, media grade and minimum efficiency are printed on each pocket. Read More

HVAC

Round Dust Collectors feature integrated cam-lock canister.

June 4, 2015

Suited for vacuum applications and other high-pressure conditions, Schust Round Collectors can operate with pressures as low as -70 in. of water column. Units feature mobile, self-centering, cam-lock canister that seals directly to collector housing, eliminating need for rotary valve. Compact bottom load bag configuration provides space savings for indoor applications. Stainless steel construction is available. Read More

Controls & Controllers, HVAC, Thermal & Heating Equipment, Test & Measuring Instruments

HPLC Column Temperature Controller features 5-program memory.

June 3, 2015

Designed to hold columns up to 30 cm long by ¼ or 3/8 in. diameter in mounting clips, EchoTherm™ Model CO50 features temperature range of 4.0–100.0°C, readable and settable to 0.1°C. Programmable chiller/heater uses PID control software to regulate temperature to ±0.2°C, and has Stable Temperature LED that illuminates when target temperature is stable to within ±0.2°C. Offering 5-program memory of 10 steps per program, Peltier-based CO50 can repeat any program from 1–99 times automatically. Read More

HVAC, Laboratory and Research Supplies & Equipment

Ductless Fume Hoods offer optional BACnet network interface.

June 2, 2015

Available in 5 standard sizes from 30–69 in. wide, Purair ECO™ Fume Hoods are designed for both chemical and particulate protection over broad range of laboratory and industrial applications. Energy-efficient ductless containment cabinets minimize stress on facility HVAC systems without compromising protection for personnel and environment. Hoods are available with choice of controllers, including ECOair™ touchpad control with color display interface. Read More

Test & Measuring Instruments, HVAC, Sensors, Monitors & Transducers

One-Color Sensors offer non-contact temperature measurement.

June 1, 2015

Designed for measurements on metals and bright/shiny materials, 16-bit Metis M3 Pyrometers are stand-alone, self-contained IR thermometers with on-board temperature display and direct analog and digital outputs for integration into PLC, DCS, and digital indicators. Models M309, M316, and M318 have spectral ranges of 0.7–1.1 µm, 1.45–8 µm, and 1.65–2.1 µm and temperature ranges spanning 550–3,300°C, 200–330°C, and 100–1,300°C, respectively. Response times are <1 ms, adjustable up to 10 sec. Read More

HVAC

External Mount Duct Fans suit space-restricted areas.

June 1, 2015

When space restrictions prevent use of inline duct fans, EXT External Mount Duct Fans offer through-the-wall solution, and can be sidewall mounted on exterior of building. Units feature external rotor motors, enclosed motor housing for dust and lint, automatic reset thermal overload protection, and built-in backdraft damper. Available in 4, 6, and 8 in. duct sizes, speed-controllable fans provide exhaust and ventilation in tight attic mountings, high rise buildings, and apartments/townhouses. Read More

Fluid & Gas Flow Equipment, HVAC, Green & Clean

Automotive Air Filters extend change intervals to 3 years.

May 29, 2015

Featuring advanced dual-stage filtration system that combines synthetic oil wetted pre-filter with pleated filter, microGreen® Extended Performance Air Filters are 99% efficient and extend change intervals up to 3 years or 45,000 miles. Filters capture and hold 3x more dirt than OEM models, keeping engines cleaner over extended use and time. Available as direct replacements for conventional filters, microGreen® filters come in axial, conical, panel, and radial designs. Read More

Controls & Controllers, HVAC, Green & Clean

Web/Smartphone Controls work with mini-split heat pumps.

May 27, 2015

Web and Smartphone (iPhone/Android) controls for mini-split heat pumps let users control temperature settings online as part of energy management dashboard. Up to 8 heating and cooling periods can be set up, and thermostat templates can be applied to multiple locations. Also, users can see costs and full impact when combined with room sensors, such as PowerWise air quality sensors, that can show temperature, humidity, CO2, and VOC levels. Read More

Fluid & Gas Flow Equipment, HVAC

Three-Stage Aerospace Filtration System delivers HEPA efficiency.

May 27, 2015

Designed for HEPA-required paint booth exhaust systems using chromate formulations, HEPA-XFP™ fits into standard 3-stage filtration frames without requiring HEPA framework. First stage uses CPA (multi-layered polyester) media, and second stage is ME/PT panel. Latter has air-entry layer of multi-layered, multi-density polyester and air-leaving media of ¼ in. thick, densified polyester. Constructed using 3 plies of electrostatic media, third stage consists of HEPA -XFP™ 6 Pocket Bag Filter. Read More

HVAC

Customizable Active Desiccant System achieves low dew points.

May 27, 2015

Comprised of 5 standard models with ratings up to 20,000 cfm, ASCENDANT™ Series cooling and active desiccant dehumidification hybrid system features regeneration input and serves applications requiring dew point temperatures as low as 20°F and air humidity levels as low as 15 grains. Operation, which does not require exhaust energy recovery, is possible as partial or dedicated outdoor air system (DOAS) or as true variable air volume (VAV) unit. Integrated DDC optimizes system operation. Read More