 Air Conditioners offer lead-lag controller option.Kooltronic Inc.
Pennington, NJ 08534
Apr 01, 2004 Model KLLC100 is optional for air conditioners equipped with 24 V relay and external connection. Suited for applications requiring multiple air conditioners on single cabinet, dual-stage device allows user to control operation based on either temperature or run-time. For fluctuating heat loads, Lead-Lag Controller will bring second air conditioner on-line as heat load increases, and shut it down as demand for additional cooling diminishes. |
Downdraft Workstation collects fines, dusts, and fumes.Tri-Mer Corp.
Owosso, MI 48867
Apr 01, 2004 Suited for metal-working operations, Downdraft Workstation captures aluminum, magnesium, zirconium, beryllium, titanium, and other volatile dusts, as well as traditional ferrous metal dusts, with 99.5% efficiency at .5 microns. Available in steel, stainless steel, or polypropylene, workstations can include Whirl Wetâ„¢ dust collector. Ten standard sizes range from 1,200–6,000 cfm. Maximum work-surface capacity is 250 lb/ft².
|
 Ceiling Modules provide cleanroom level air filtration.Filtra Corp.
Riverdale, NJ 07457
Mar 30, 2004
Replaceable PharmaSeal® Ducted Ceiling Modules feature guillotine-type control damper with adjustable linkage. Airflow may be adjusted from 10-98% of rated filter flow. Available in 0.063 aluminum or 16 GA 304 stainless steel, modules may be installed in T-bar ceilings or flush-mounted in plaster or sheet rock ceilings. Gel seal filters offer removal efficiencies from 95% at 0.3 micron to 99.9995% at 0.12 micron.
|
 Blower Package includes sound-dampening enclosure.Kaeser Compressors, Inc.
Fredericksburg, VA 22404
Mar 30, 2004 Com-paK Plus Series, with integral ventilation fan, features Omega Plus rotary tri-lobe blower in compact package. All maintenance points are accessible through wide-opening canopy on front of unit. All power and process connections are at rear, allowing multiple units to be mounted side by side without additional access clearance. Enclosure permits typical noise levels of 75 dB(A) or less. |
Roof Fans perform up to 1.25 in. wg and 37,500 cfm.Greenheck Fan Corp.
Schofield, WI 54476 0410
Mar 30, 2004 Suited for general clean air applications, Series L low silhouette, centrifugal fans are available in Fabra hood style or louvered penthouse style versions. Penthouse units offer severe-duty housing that can endure high winds and wind-blown debris. Fans meet stringent Miami-Dade County test protocols for large missile impact, uniform static air pressure, and uniform cyclic wind loading. |
 Boom Lifts offer integrated air-compressor accessory.JLG Industries, Inc.
McConnellsburg, PA 17233 9533
Mar 26, 2004 SkyAirâ„¢ Compressor fits under hood of company's boom lifts and is driven by 7,500 W SkyPowerâ„¢ generator. It delivers air to platform-mounted regulator through airline integrated into powertrack. Compressor can provide up to 9.3 cfm at pressures of 125 lb/in² to operate ½ in. drive impact wrenches, air hammers, drills, and other tools. SkyAir helps promote job site safety by eliminating dangers from airlines hanging over platform rails. |
 Compressed Air Filter can also be used as prefilter.Parker Hannifin Corp., Filtration & Separation Div. Balston Products
Tewksbury, MA 01876
Mar 26, 2004 Designed as point-of-use breathing air filters, BA-Series dual-stage filters are available in ¾ and 1 in. NPT connection sizes. Max pressure is 500 psig, and max temperature is 175°F. Flows go up to 75 scfm. Each housing has 2 elements inside: coalescer, which removes more than 99.97% of oil, water, and solid contaminant, and adsorber, where carbon element collects hydrocarbon vapors. Manual drain port (1/8 in.) is standard. |
Toroidal Conductivity Sensor suits biochemical industry.Emerson Process Management
Knoxville, TN 37932
Mar 26, 2004 Rosemount Analytical Model 245 flow-through toroidal conductivity sensor works with viscous, fibrous, and corrosive samples. Sensor design consists of one pair of isolated, wire-wound toroids, enabling unit to withstand harsh environments of pharmaceutical, biochemical, and food and beverage processing. Available in 4 line sizes from ½â€“2 in., sensor is manufactured with 316L Stainless Steel, EP, and unfilled-PEEK and meets 3-A sanitary standards. |
 Motorized Blower suits low-noise applications.Continental Fan Mfg. Inc.
Buffalo, NY 14215
Mar 25, 2004 Speed-controllable, Model TCC meets AMCA B spark-resistant requirements. It combines computer-designed, flange-mounted scroll housing with TMK Motorized Impeller. Steel housing has corrosion-resistant epoxy coating for maintenance-free operation. Typical applications include electronic cabinet cooling, clean room modules, heat exchangers, air filtration, pharmaceutical equipment, and semiconductor industry. |
 Electronic Temperature Control is suited for boilers.Wayne Combustion Systems
Fort Wayne, IN 46803
Mar 23, 2004 Hydronix Triple Limit Boiler Control features multi-position mounting capabilities, aluminum casing, replaceable plug-in sensors, solid-state relays, and LED indicators with diagnostics. Redundant safety systems monitor relays and sensors and instantly detect errors. Computerized supervisory systems ensure that every aspect of control is operating properly before heat cycle is started. |
Heat Pump suits northern climates.EnerKon Corporation
Freeport, ME 04032
Mar 23, 2004
Cold Climate Heat Pump(TM) provides continuous heating down to and below 0°. It uses multiple stages of heating through Bristol® TS Compressor, booster compressor, and economizer. These components, along with Johnson Metasys Control, respond to indoor and outdoor air conditions for both heating and cooling seasons. Coefficient of performance is 2.7 at 17°F and 2.0 at 0°F. Available in 2.5, 3.5, 4.0, and 5.0 ton models, pump uses EPA-approved R-410A refrigerant.
|
 Ultrasonic Humidifier features duct-mountable design.Humidifirst
Harrisburg, PA 17101
Mar 22, 2004 Model DT-60 produces 60 lb/hr of 1 micron mist while consuming 1,410 W. Multiple units can be proportionally controlled by Model HC-300 microprocessor. Unit benefits HVAC industry by allowing smaller duct sizing and reduced air restriction. |
Baghouse Filters offer alternative to polyester felt bags.Donaldson Co., Inc.
Minneapolis, MN 55440-1299
Mar 22, 2004 Dura-Lifeâ„¢ filters utilize Durapexâ„¢ media technology and assist in reducing emissions levels in industrial applications to meet indoor/outdoor environmental standards. Engineered with Apex® technology, which consists of hydroentanglement manufacturing process, products help reduce amount of dust that escapes into air. They are suited for manufacturing industries such as lumber, food, rubber, chemical, stone, mining and paper. |
 Dust Collectors provide filtration and separation.Tri-Mer Corp.
Owosso, MI 48867
Mar 17, 2004 Suited for collection of large particulate and pre-filtering, Cyclonic Particulate Collectors feature separate dust collector trap and direct-drive fan. Products are custom manufactured in carbon steel, stainless steel, exotic metals, or all polypropylene, with urethane, rubber, or refractory linings. They are suited for use where high dust loadings, high temperatures, highly abrasive dusts, or sticky dusts exist. |
 Flow Sensors use thermal dispersion technology.Fluid Components Intl.
San Marcos, CA 92069 5115
Mar 15, 2004 Series 180 Flow Sensors, with no moving parts, provide switching, alarming, rate metering, and totalizing of air, gases, or liquids. Line sizes from 0.25–6 in. are supported. Thermowell-mounted, platinum RTD sensors prevent contamination by process fluid. Mean time between failure exceeds 60,000 hr. Applications include fuel and air feed lines, additive dispensing control, oil and lubricant circulation, pump protection circuits, cooling system controls, and over/under flow limit switches. |
 Portable Chillers offer 1½, 2, or 3 hp compressors.PolyScience Div. Of Preston Industries Inc.
Niles, IL 60714 4588
Mar 12, 2004 DURACHILLâ„¢ Chillers provide up to 35,827 BTU/hr heat removal. They offer user-adjustable temperature, pressure, and flow rate alarms, as well as automatic condenser pressure cutouts. Units are suited for process temperatures from 41–95°F and can maintain set point temperature with ±0.9°F stability. Air- and water-cooled chillers include digital microprocessor temperature control and LED temperature and pressure/flow rate displays. |
 Centrifugal Fan offers capacities to 4,000 cfm.Continental Fan Mfg. Inc.
Buffalo, NY 14215
Mar 12, 2004 Ranging in diameter from 12–24 in., in-line Model TID features TEK backward curved airfoil impeller, non-overloading power characteristics, and AMCA B construction. Fan is suited for OEM applications or new construction. |
 Coolant Recovery System helps reduce endotoxins.Sanborn Technologies, North American Filtration of Massachusetts, Inc.
Walpole, MA 02081
Mar 11, 2004 Pioneer integrated on-site coolant recovery system includes disc centrifugation and flash pasteurization to end rancidity, coolant odor, and dermatitis caused by coolant contact. Reduction of bacteria in coolants helps prevent development of endotoxins. Unit removes solids to 1 micron and tramp oil to 0.25%, and processes water-soluble and semi-synthetic coolants. It can return 95% of recoverable fluids for reuse. |
 Portable Fume Extractor protects welders.Sentry Air Systems
Houston, TX 77092
Mar 11, 2004 Protecting welders from inhalation problems associated with toxic metallic fumes, Sentry Portable Welding Fume Extractor draws and filters irritating/dangerous fumes away from welding work stations. Freestanding fan/filter unit achieves air volume of 50–350 cfm. Constructed of 16 ga. carbon steel, modular unit incorporates 6 in. round, 58 in. long, self-supporting flex arm. Unit achieves efficiencies to 99.97% @ .3 microns with HEPA filters. |
 Cold Air Tubes deliver sub-zero air.ITW Vortec
Cincinnati, OH 45242-4719
Mar 11, 2004 With no moving parts, Cold Air Tubesâ„¢ convert compressed air into low pressure stream of cold air that reaches temperatures as low as -20°F. They kill heat buildup that can slow production or create problems on parts and equipment. At less than 10 in. long, maintenance-free cooling component is adaptable for numerous applications, with 3 models available offering different cooling capacities. Tubes provide quiet operation and instant on/off. |
(Showing headlines 1581 - 1600) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105
|
|
|