HVAC

Test & Measuring Instruments, HVAC, Sensors, Monitors & Transducers

Infrared Temperature Sensor suits autosports applications.

June 5, 2009

With 150, 200, and 800ºC temperature ranges, ETIS series is designed for demanding tire, brake, and exhaust temperature measurement in autosports. It has 1,000 G shock rating and is packaged in lightweight aluminum housing measuring 20 x 18 x 12 mm and weighing 26 g. Available with front facing M3 fixing holes and 1 m long shielded leads, unit operates in ambient temperatures between 0-120ºC with 30-70 mm measurement stand-off distance and target area of approximately 20 mm dia. Read More

HVAC, Electrical Equipment & Systems, Green & Clean

Solar Panel delivers conversion efficiency of 19.3%.

June 4, 2009

Designed for installation in residential and commercial applications, SunPower® 315 Solar Panel features anti-reflective coated glass that optimizes capture of diffuse off-angle light and subsequently maximizes energy generation. This 96-cell, 315 W panel incorporates all-back contact solar cells to maximize energy production, resulting in fewer panels per rooftop while also offering aesthetically pleasing appearance. Read More

HVAC

Abort Gate increases dust collection equipment safety.

June 3, 2009

Featuring heavy-duty, fully welded steel construction and OSHA safety yellow paint, High Speed Abort Gate can be located prior to inlet of dust collection system to prevent ingress of flame or burning ember. It can be actuated by leak detection or broken bag sensors and may also be placed on return air side of dust collector to redirect contaminated air to safe location. Other features include gate accelerating springs; fail-safe electro-magnets; steel gate seals; and limit switches. Read More

HVAC, Green & Clean

Portable Chiller utilizes EPA-compliant R410a refrigerant.

June 2, 2009

Available in air- and water-cooled versions, GP Series features leaving coolant temperature range of 20-80°F and electronic modulating capacity control that maintains temperature to within 0.1°F. Electronic sensors monitor leaving/entering fluid temperatures, compressor suction/discharge pressure, condenser inlet temperature, pump pressure, and tank level. LCD shows operating status, set point, and to-process temperature on multiple screens. R410a refrigerant is chlorine-free. Read More

HVAC

Portable Cooling System cools up to 1,000 sq ft.

June 2, 2009

Port-A-Cool® JetStream 1600 portable evaporative cooling unit is suited for mechanic's bays, work shops, small work areas, and patios. It includes louvers to direct airflow, built-in cord wrap, and water fill options utilizing built-in reservoir or garden hose. Using tap water and 115 V of electricity, device lowers temperatures by 15-25°F. Its 1-piece housing eliminates leaks and rust while KUUL® Pads cooling media maximize operational capabilities. Read More

Test & Measuring Instruments, HVAC, Sensors, Monitors & Transducers

Inductive Sensors can operate in environments up to 230°C.

June 2, 2009

Featuring sizes ranging from miniscule 4-30 mm, inductive sensors are available in short-housing models with option of square or rectangular shape. They offer choice of NAMUR, AC/DC, NPN or PNP output, NO or NC output, and programmable output, and come with 2, 3, or 4-wire, connector or cable, with 360° LED indicator. Choice between shielded or unshielded sensors is available for high-heat and standard applications. Read More

HVAC

Condensing Boilers have replaceable SS flexible tubes.

June 1, 2009

Triple-Flex(TM) condensing flexible water tube boilers fire at 3,000 MBH input, with sub 30 ppm NOx levels, utilizing hybrid metal fiber 5:1 turndown burner and SOLA hydronic safety controls and interface systems. Other features include variable speed combustion air blower and removable access panels making boiler interior accessible for service and inspection. Triple-Flex(TM) boilers deliver operating efficiencies of 99% in new buildings designed for condensing boiler conditions. Read More

Safety & Security Equipment, HVAC, Laboratory and Research Supplies & Equipment

Medical Ventilator is designed for mice.

June 1, 2009

Suitable for any animal with tidal volumes of 30-350 µL and respiratory rates of 60-400 breaths/min, MiniVent features rod clamp that allows it to be positioned directly next to animal. Ventilator employs valveless rotary plunger that eliminates clogging during ventilation cycle. Inspiration and expiration is controlled by synchronized forward and rotating movement of cylinder and plunger. Compact and lightweight unit reduces tidal volume error due to system compliance to 3 µL. Read More

HVAC

Vane-Axial DC Fans suit high static pressure applications.

May 28, 2009

Available in 12, 24, and 48 Vdc configurations and 120 x 38, 92 x 38, 80 x 38, and 60 x 38 mm frame sizes, VA Series Fans feature dual ball bearing system with brushless DC, auto restart, polarity-protected motor. Units maximize airflow even in nearly sealed enclosures, making them suited for networking and telecommunications equipment, industrial electronic cabinets, and medical imaging equipment. PWM, tachometer, alarm, and thermal control options are available. Read More

HVAC, Computer Hardware & Peripherals, Plant Furnishings & Accessories

Cooling Enclosures suit network closet, server room areas.

May 28, 2009

Featuring up to 7 kW of cooling capacity, 600 mm wide rack enclosure, as well as front and rear containment options, InRow® SC Systems can be deployed as fully contained IT environment or partially contained system that can be added as retrofit. Self-contained solutions monitor and actively adjust cooling capacity to ensure proper server inlet temperatures. Intelligent and manageable components make the system network-enabled and self-monitoring. Read More

Test & Measuring Instruments, HVAC, Sensors, Monitors & Transducers

Temperature Measurement System has multi-sensor capability.

May 27, 2009

Delivering performance for real-time, in-process temperature sensing applications, wireless TempTrackr(TM) allows for parallel interrogation of several independent passive temperature sensors. SAW-based sensors maintain unique identification within system architecture and require no power source. Along with 4 dipole antennas and wireless interrogator, TempTrackr Multi-Sensor kit includes 4 sensors capable of reading temperatures between 0 and +120°C from max distance of 70 in. Read More

Test & Measuring Instruments, HVAC, Sensors, Monitors & Transducers

Sensors monitor hydraulic systems aboard aircraft.

May 22, 2009

Housed in stainless steel with MIL-38999 style connector, Combined Pressure and Temperature Sensors are available in pressure ranges of 0-500 through 0-10,000 psia with temperature range of -55 to +125°C and accuracy of ±1.0% FSO. Operating on 5-15 Vdc, sensors can be configured with amplified 0.5-4.5 Vdc or non-amplified 50-100 mV at 10 Vdc excitation output. Sensors can withstand harsh environments, and are suited for active control systems, system status, and health monitoring. Read More

HVAC, Green & Clean

Environmental System prevents ventilation air contamination.

May 22, 2009

Secure Environmental System(TM) (SES) ecologically safe technology which prevents contamination of building ventilation air from outside sources. It also exchanges temperature and humidity between airstreams with bactericidal and virucidal desiccant transfer solution, which provides energy recovery and removes airborne contaminants. Ventilation and exhaust air are handled by separate units; no cross leakage or microbiological cross-contamination of exhaust air to ventilation air can occur. Read More

HVAC

Fume Extractor removes smoke, fumes, and heat at source.

May 22, 2009

Available in 4 models with fume extraction capacities from 400-1,150 cfm, Place-A-Vent is designed for removing and ventilating fumes produced by welding, brazing, soldering, laser cutting, plasma cutting, and similar operations. It employs negative pressure system that exhausts all fumes quickly to outside or into existing ductwork. Accessories include flexible gooseneck hood support arms and customized systems are also available. Read More

HVAC

Injection Systems help mitigate multi-pollutant emissions.

May 20, 2009

Using dilute-phase positive-pressure pneumatic conveying technology, Sorb-N-Ject(TM) Technology injection systems continuously transfer dry bulk sorbent material from storage silos to injection ports on boiler flue gas ducts, which reacts with multi-pollutants in flue gas to reduce emissions. Fluidizing bin bottom installed on each silo prevents stored material from rat holing, bridging, or arching. System includes loss-in-weight feeder hopper with reverse jet pulse dust filter system. Read More

HVAC, Thermal & Heating Equipment

Cable Kit simplifies floor warming coverage.

May 18, 2009

Warm Tiles® DFT 120 V floor warming cable kit allows contractors to install full floor warming coverage simply by lacing free form cable on floor wherever heated area is required. Cables can be used over variety of substrates including plywood, backer board, and concrete, and are placed 3 in. apart in typical room above heated area, and 1.5 in. apart for room above unheated area, on concrete slabs, or in high heat loss room. Kits are available for heating areas from 11-108 sq ft. Read More

HVAC

Vehicle Air Conditioning Condenser Unit 24 x 18 in. footprint.

May 15, 2009

With internal hydraulic compressor drive that requires flow of 8 gpm at 1,200-1500 psi, Model 3110 condenser unit for work equipment can be paired with wide variety of in-cab air conditioners and heater components. It is rated at 24,000 BTU/hr and features formed and welded steel construction, powder coating, and fully hydraulic component isolation. Optional equipment includes diesel fired coolant heater and variety of cab air filtration and pressurization systems. Read More

HVAC, Laboratory and Research Supplies & Equipment

Industrial Steam Boilers suit laboratory applications.

May 14, 2009

Designed for industrial marketplace, Model ES electrically heated saturated steam boiler suits laboratory, hospital, industrial plant, pilot plant, as well as food and chemical processing applications requiring steam from 0-100 psig. It features automatic pressure and liquid level controllers as well as ASME Code pressure vessel and safety valve. Installation only requires water feed connection and electrical hook-up. Read More

HVAC, Chemical Processing & Waste Management, Fluid & Gas Flow Equipment

Vacuum Pumps and Compressors range from 1½ to 10 hp.

May 13, 2009

Available with Monoblock or Pedestal drive arrangement, Vectra SX Series Liquid Ring Pumps and Compressors come in 3 variations to meet different process needs. High vacuum version provides performance to 1 in. HgA, while water handling version handles large amounts of process water or carryover, and compressor version is designed for wide pressure range. Units are available in all 316 precision cast stainless steel or cast iron with cast 316 SS impeller and corrosion-resistant pump. Read More

Test & Measuring Instruments, HVAC, Sensors, Monitors & Transducers

Temperature Sensor features separate electronics module.

May 13, 2009

Measuring temperatures from -20 to +500°C, PyroCouple M series sensors include model PCM21 with 2:1 optics, PCM151 with optical resolution of 15:1, and PCM301 with resolution of 30:1. Each features miniature 18 mm dia x 45 mm sensing head, made of SS and sealed to IP65, which connects via EMI-resistant cable to 98 x 64 x 34 mm electronics module powered from 24 Vdc power source. Noncontact sensors have 250 ms response time with signal stability optimized by adaptive filtering. Read More