Multifunctional Machine dries, cools, and classifies.

July 16, 2009

Developed for plastics industry, DC Classifier(TM) utilizes either positive or negative air flow to draw moisture and heat away from particulates to dry/cool material. Material continues through machine to classification stages, where oversize and fine particles can be removed. Modular decks facilitate removal for cleaning in-between process changes, when more than one material type or color is processed in same machine, and casters are available to meet mobility requirements. Read More

HVAC, Plant Furnishings & Accessories, Architectural and Civil Engineering Products

Louvered Penthouses are Miami-Dade qualified.

July 15, 2009

Designed to function as gravity ventilators or equipment enclosures, Models ESD-635PD and EHH-601PD are approved for use inside or outside Florida's High Velocity Hurricane Zone. Model ESD-635PD features 6 in. deep drainable-style louver blades, while Model EHH-601PD has 6 in. deep, horizontal, wind-driven rain louver blades. Both feature all-aluminum construction and max design wind load of 115 psf. Offered in heights of 12-84 in., units offer throat sizes from 12 x 12 to 84 x 108 in. Read More

HVAC

Safety Ventilator includes hold function.

July 15, 2009

Suitable for variety of animals from mice to cats, Inspira Advanced Safety Ventilator with Inspiratory Hold function is available in both volume and pressure controlled models. Unit features airway pressure monitoring, adjustable I:E ratio, built-in sigh breath, and Assist Mode to help wean animal off ventilator. To utilize Hold function, user enters desired hold time and initiates hold with touch of button. Read More

Test & Measuring Instruments, HVAC, Sensors, Monitors & Transducers

Level and Flow Monitor provides isolated 4-20 mA output.

July 14, 2009

Featuring non-contacting ultrasonic sensor and built-in 3-key calibration system, Model SLT32 can be used as level transmitter for tank inventory applications with continuous display and control, or as open channel flow monitor with display, totalization, control, and analog output. Unit includes PVC and Teflon® sensor rated for ranges up to 32 ft, NEMA 4X electronics enclosure, 2 digital displays, and 3 programmable control relays. Read More

Test & Measuring Instruments, HVAC, Computer Hardware & Peripherals, Electrical Equipment & Systems

PCIe Gen2 Switches offer temperature sensor functionality.

July 14, 2009

Optimized for servers, storage, and communications/networking, PCI Express® Gen2 switching solutions come in 10-lane/4-port, 12-lane/3-port, and 16-lane/4-port models. Units provide line rate throughput and integrated IDT Power Smart technology to solve system-level thermal management challenges in enterprise applications. Integration of temperature sensor enables optimized power management, load balancing, and mitigation of potential thermal-related faults and outages. Read More

HVAC

Dust Collectors control airborne dust at belt conveyors.

July 9, 2009

Capable of controling airborne dust at belt conveyor loading points and bulk material handling operations, MARTIN® insertable dust collector suits applications with non-explosive materials in non-hazardous locations. They feature pulse cleaning system where short pulse of air is sent back through filter to dislodge accumulated material. Small filter elements are made from mesh-like material and filter change is one-hand, no-tool procedure. Read More

HVAC

Downflow Booths protect against exposure to aerosols.

July 7, 2009

Pharmacon Downflow Booths are used in the pharmaceutical, fine chemical, and food industries for operations such as sampling, grinding, dispensing, and filling that generate airborne particles. Modular design offers widths, starting at 4.92 ft, which can be increased in 19.5 in. increments; single-, two-, or three-stage HEPA or ULPA filtration; and re-circulatory or single-pass airflow. Containment performance is verified according to ISPE Good Practice Guide. Read More

HVAC, Controls & Controllers

Panel-Mount Thermal Loop Controller comes in 1/8 DIN size.

July 1, 2009

Offered in horizontal/vertical configurations, EZ-ZONE® PM 1/8 DIN allows for integration of power controller with PID controller and over/under limit controller in one package. Character and button size promote usability, and case slots aid in removal of control hardware from front-pluggable DIN chassis. Features include dual-channel PID control, cascade control, square-root linearization, and wet/dry bulb capability as well as ratio and pressure to altitude compensation curves. Read More

HVAC, Green & Clean

Air-Cooled Chiller features 3 efficiency levels.

June 30, 2009

Offering standard, high, and premium operating efficiencies, Daikin McQuay Pathfinder(TM) air-cooled chiller is designed to help building owners qualify for LEED® certification. Capacities range from 175-515 tons in both 50 and 60 Hz. Featuring low-speed fans and single-rotor compressor, unit's sound pressure level is rated as low as 67 dBA at distance of 30 ft per ARI Standard 370. Key components are located on its periphery for simplified access to commonly serviced parts. Read More

HVAC

A/C Unit protects electronics enclosures against heat.

June 29, 2009

Vortex A/C NEMA 12 delivers Total Enclosure Protection to ensure reliable operation in extreme environments. Along with 62 dBA operation, features include maintenance-free design, capacities from 900-5,000 BTU/H, and integral mechanical thermostat that maintains 80 to 90°F temperatures. Enclosure cooling product operates in environments up to 175°F and offers slight pressurization of enclosure in all operating modes. Top- or side-mount installation requires no wiring. Read More

Test & Measuring Instruments, HVAC, Sensors, Monitors & Transducers, Green & Clean

CO2/Temperature WiFi Sensor helps conserve energy in buildings.

June 26, 2009

Designed to utilize existing IEEE 802.11 voice/data networks, wall-mounted TR9294-WF can be used to regulate outside air ventilation based on actual number of people in particular space. Signal can be directed over local network to building control system and/or over Internet to any remote monitoring/data collection location. Self-calibrating and maintenance-free sensor uses 24 Vac low-voltage power and supports wireless encryption protocols as well as DHCP or static IP address. Read More

Test & Measuring Instruments, HVAC, Sensors, Monitors & Transducers

Transmitter combines humidity and temperature sensing.

June 26, 2009

Series RHP combines voltage or current humidity transmitter output with passive temperature thermistor or RTD output. Polymer capacitance humidity sensor is not affected by condensation, fog, high humidity, or contaminants, and humidity sensors are available with 2% or 3% accuracies. In addition to optional 2-line alphanumeric LCD, duct-mounted transmitters are available with interchangeable filter options and replaceable sensors. Read More

HVAC, Green & Clean

Smart Cooling Modules include integrated control boards.

June 25, 2009

Designed to enhance efficiency of high density cooling systems, Liebert XD Smart Modules reduce energy consumption by controlling cooling fans based on cooling load at each individual module. They are supported by Liebert XDP pumping unit that acts as interface between pumped refrigerant circuit and building chilled water system, and Liebert iCOM control system that allows all key functions to be continually monitored. Read More

HVAC

Blower features backward curved airfoil wheels.

June 25, 2009

Manufactured of glass-reinforced polyamide, TCD BC Airfoil Blower features compact, rugged design with epoxy coated steel housing. It comes with either single- or 3-phase TEFC motor and delivers capacities to 4,500 cfm. Direct drive, non-overloading TEK impeller's features include flanged and drilled outlet, ABS inlet cone, and CW rotation, rotatable to 5 positions. Read More

HVAC

Compact Chillers provide up to 1,290 W of cooling at 20°C.

June 22, 2009

Designed to maximize bench space, LS-Series are available with centrifugal or turbine pump, while LM- and MM-Series come with 2 different centrifugal pumps. LS-Series has working temperature range of -20 to +40°C and provides 475 W of cooling at -10°C; LM-Series works in temperature range of -10 to +30°C and 230 W cooling capacity at -10°C; and MM-Series has working temperature range of -5 to +50°C and provides 130 W of cooling at -5°C. Read More

HVAC

DIY Tile Floor Heating System is waterproof, GFCI-protected.

June 22, 2009

With sizes ranging from 20-300 ft² with options for 120 V systems up to 150 ft² and 240 V systems for 60-300 ft², TileWarm(TM) DIY features micro-thin element that is less than 1/16 in. and causes no floor buildup. Kit includes heaters needed for coverage specified, continuity monitors for each heater, SecuraMat(TM) protective membrane, and installation information/accessories needed. Shielded, helically wound element with full ground surround eliminates risk of overheating. Read More

HVAC

Fan optimizes airflow around memory modules.

June 17, 2009

Designed specifically to keep Kingston® HyperX memory cool, HyperX Fan is made of anodized aluminum with blades that are illuminated by 8 small blue LEDs when turned on. Fan uses minimal power and produces max acoustical noise of 25 dBA. It is available as standalone unit or bundled with 6 GB 2,000 or 1,800 MHz triple-channel memory kits with T1 heatspreaders for Intel Core i7 systems. Read More

HVAC, Computer Hardware & Peripherals

CPU Cooler targets Intel® and AMD processors.

June 16, 2009

Supplied pre-filled and fully connected, Corsair Cooling(TM) Hydro Series H50 utilizes copper CPU cooling plate and integrated pump connected to 120 mm radiator and low-noise fan. Low permeability tubing virtually eliminates evaporation and leaking. Closed-loop system includes mounting brackets for both Intel LGA775 and Intel LGA1366 socket motherboards. Brackets for AMD socket AM2 and AM3 motherboards are also available. Read More

HVAC

Shop Floor Fans suit industrial/warehouse environments.

June 15, 2009

Patterson Shop Floor Fans are suitable for continuous operation, allowing control of air flow in 3 speeds up to 7,500 cfm on 30 in. models and 10,000 cfm on 34 in. units. They feature welded steel hulls, powder coated finish, 115 V motors, as well as semipneumatic wheels with optimized maneuverability. Read More

HVAC

Dust/Fume Collector targets small airflow applications.

June 12, 2009

Measuring 38 in. square and under 8 ft high, Gold Series® GS4M Mini dust collector controls emissions from airflow applications up to 2,000 cfm. Rugged, compact unit features 3 hp fan motor that handles 1,000 cfm at 9 in. wc or 2,000 cfm at 5 in. wc static pressure. Featuring fan with less than 70 dB noise, filters, and cleaning system, unit contains 4 HemiPleat® flame retardant filter cartridges with 788 sq ft of media rated at 99.99% efficiency on 0.5 micron particles. Read More