HVAC

HVAC, Green & Clean

Attic Fans feature solar powered design.

April 29, 2009

Suited for existing homes as well as new construction, Solar Powered Attic Fans expel hot air from home attics, pulling cooler air in from outside without using electricity. Fans also circulate air during winter, removing damaging moisture, which can cause buildup of mold and mildew. Able to ventilate up to 1,250 ft² of attic space, units include thermal switch that turns off fan when attic temperature drops below 65° and back on when attic temperature reaches 80°. Read More

HVAC, Fluid & Gas Flow Equipment, Welding Equipment & Supplies

Extraction Hood and Filter Bank provide weld fume control.

April 27, 2009

Modular Extraction Hood features semitransparent welding strips to prevent cross drafts and control airflow direction. Double-panel roof configuration acts as in-line baffle, deflection plate, and spark arrestor to protect ductwork. Incorporating dust hopper collector and MERV 16 rated filters, Statiflex® Filter Bank can contain 1 of 8 filter units, with filtration station ranging in sizes from 2-32 banks. Both systems remove welding fume and grinding particulate during welding applications. Read More

HVAC, Controls & Controllers

Fan Drives and Controller reduce fuel consumption and noise.

April 22, 2009

Designed to aid in cooling of hotter-running, reduced-emission engines, VMaster® and Stratis(TM) Di Viscous Fan Drive and Controller systems offer precision, variable-speed performance. Endurance-tested VMaster Di responds rapidly to changing cooling requirements and offers optimized torque transmission and fan idling speed. Stratis Viscous Fan Drives feature reservoir, actuator, and valve system that optimizes response time to increase airflow and cooling. Read More

Test & Measuring Instruments, HVAC, Sensors, Monitors & Transducers

Refrigerant Temperature Sensor meets CA Energy Standards.

April 16, 2009

Designed to monitor refrigerant temperature in condenser and evaporator coils, Sens-A-Coil comes with 3 ft of Type K thermocouple cable and male plugs to connect directly to digital thermometer. Unit satisfies requirements on regulations that saturation temperature sensor must be part of system once it is installed so that refrigerant temperature can be verified by 3rd party raters. Sensor element is integrated into plastic overmolded copper clip, which snaps onto 3/8 in. return bends. Read More

HVAC, Green & Clean

Humidifiers feature safe, non-electric design.

April 15, 2009

Powered by Hydro pneumatic capillary system, Non-Electric Humidifiers expel moisture at rate of 10-20 cm/sec. Because they do not have fans or motors, units create no noise or dust vapor and no risk of fire hazards. There is also no buildup or distribution of mold, germs, and other toxins. Seven wall-mounted models are available in different designs to match decor. Read More

Test & Measuring Instruments, HVAC, Sensors, Monitors & Transducers

IR Sensors measure temperature of metals and composites.

April 13, 2009

With double laser sighting, inline thermoMETER CT laser M3 measures at short wavelength of 2.3 µm for temperatures from 50-600°C. Unit features 100:1 optical resolution and minimum spot size of 0.7 mm. For temperatures from 250-1,800°C, thermometerCT laser M1/M2 sensors also include double laser sighting, but have 300:1 optical resolution, minimum spot size of 0.45 mm, and wavelengths from 1.0-1.6 µm, which minimizes temperature measurement errors. Read More

HVAC

Air Conditioner suits off highway/over the road vehicles.

April 10, 2009

Available as cool only or as air conditioner and heater for on/off-road heavy duty equipment, Model 4050 can be mounted on either wall or ceiling. With footprint of 18.5 x 6.5 x 17.25 in. for cool only and 18.5 x 6.5 x 20.5 in. with optional heater, unit has 18,500 BTU cooling and 32,000 BTU heating capability. Ducting options and remote mount controls also allow for installation behind seat. Read More

HVAC, Thermal & Heating Equipment

Heat Blowers utilize long-life heating element.

April 10, 2009

Offering air delivery rate up to 23 cfm, Professional Heat Blower Series feature color-coded temperature keys, which lock in specific temperatures from 200 to 1,200°F, to enable at-a-glance verification. Adjustable stand supports the blower during bench work and stores temperature keys when not in use, and balanced design helps reduce fatigue during long-term, hand-held use. Applications include window tinting, packaging, shrink wrapping, thawing pipes, and working with plastics. Read More

HVAC, Fluid & Gas Flow Equipment

Mist Collector incorporates multi-layer filter design.

April 9, 2009

Providing filter life of 1-5 yr, depending on application, MistMax(TM) is engineered to achieve efficiency of up to 99.98% without use of additional HEPA filters. Unit is suited for controlling oil and coolant mist in applications such as high-speed machining centers, heat treating, cold drawing, and wet grinding. Read More

Material Handling & Storage, HVAC, Electrical Equipment & Systems

Generator/Compressor Unit features space-saving design.

April 9, 2009

Measuring 70 x 30 x 48 in. and weighing only 1,850 lb, 4040 generator compressor combination unit features commercial-grade, diesel-powered generator and industrial-duty compressor, directly running off same engine. It produces 40 cfm of air with low-speed Schulz piston compressor or upgraded rotary screw compressor. Operating at 1,800 rpm, generator delivers 40 kW with rugged, 4-cylinder, Kubota V-3300-T engine, and also offers quiet operation. Read More

HVAC

Fan directs air around obstructions or down long aisles.

April 9, 2009

Measuring 6 ft in diameter, Pivot Fan incorporates 2 independent pivot points that allow adjustment for directional airflow in 73 positions. Airfoil profile and winglet combination allow Pivot to gently distribute maximum airflow in small spaces. Featuring low-profile cage that protects both fan and occupants, Pivot is suitable for manufacturing, bottling and distribution facilities, aviation hangars, fitness clubs, schools, and firehouses. Read More

HVAC, Chemical Processing & Waste Management

Compact Mist Collector measures 27 x 21 x 20 in.

April 6, 2009

Installed directly on machining center or suspended from ceiling, Smog-Hog MSH mist collector utilizes variable speed drive motor, producing air volume up to 500 cfm, that enables users to adjust airflow and overall energy use as needed. Heavy-duty mist-stop coalescing prefilter and metal mesh after-filter provide maximum contaminant collection, and large capacity ESP collection cell minimizes filter changes. System's sound levels are less than 72 dbA. Read More

Material Handling & Storage, HVAC, Fluid & Gas Flow Equipment

Modular Tools clears air for any tool and any application.

March 27, 2009

Comprised of filters, regulators, and lubricators, ARO-Flo products come in 4 series that vary in port size (1/8-1 in.) and max standard cubic feet per minute (57-381 scfm). They clean and lubricate air for use with pneumatic tools and incorporate multiple safety features, such as positive-locking thumb switch on all polycarbonate filter bowls. Integral gauge fan, also included, provides visual display for monitoring pressure to ensure it stays within targeted range. Read More

HVAC

Rotary Blowers feature integrated controller.

March 27, 2009

Available from 7.5-60 hp with capacities up to 812 cfm at 3 psig, Models 166C and 236C Com-paK Plus DB Series Blowers are equipped with Omega Control Basic(TM) controller, which integrates motor starters and instrumentation. Units have tri-lobe blower design and enables user to select between reduced voltage starter and frequency converter. Read More

HVAC, Controls & Controllers

Dual-Function Fan Control replaces thermal time delays.

March 27, 2009

Measuring 2½ x 2½ in., single-speed R60B provides control of line voltage fan motor used in heat pumps, air-conditioning, and forced air systems. This electronic fan control board, powered by 24 Vac input, accepts 24 Vac fan signal from thermostat. Fixed 1 sec fan ON delay eliminates thermostat bounce, while fixed 45 sec post fan OFF delay increases efficiency by purging air ducts of residual air. Secure screw-in terminals are provided for R, C, and G connections. Read More

Test & Measuring Instruments, HVAC, Sensors, Monitors & Transducers

NTC Thermistors are offered with customizable options.

March 26, 2009

Available in both probe and plastic disc type, NTS Series temperature sensors suit consumer electronics, automotive, and food handling and processing applications. Built with negative temperature coefficient, they measure changes in resistance with varying temperature. Coupled with electronic control, UL1434 compliant products provide control over heating elements and relays. Custom feature include NTC between 1-100k W resistance along with custom housings and lead lengths. Read More

Test & Measuring Instruments, HVAC, Sensors, Monitors & Transducers

Sensors are designed for measurement of internal ballistics.

March 26, 2009

Structured with acceleration-compensated quartz sensing elements, Series 119B and 109C dynamic ICP® and charge output pressure sensors feature ceramic coating on diaphragm for thermal shock delay during pressure measurement and also allows for flush mounting. On-board electronics provide conditioned output signal and can transmit noise-free signals over long cable runs. Sensors are available with full-scale measurement ranges to 100k psi and sensitivity up to 20 mV/psi. Read More

HVAC

Low-Profile DC Blowers provide spot cooling solutions.

March 24, 2009

Used for directional cooling in space-constrained applications, ODB600PT and ODB9733 Series measure 120 x 120 x 32 mm and 97 x 94 x 33 mm, respectively, and are comprised of 12, 24, and 48 V models. Each series features brushless DC motors, locked rotor and polarity protection, as well as auto restart functions. While ODB600PT blowers come in 1,800, 2,500, and 3,000 rpm speeds and feature 20-35 cfm airflow range, ODB9733 devices offer 3,300 or 5,000 rpm and 22 or 35 cfm ratings. Read More

HVAC

Water Circulator facilitates heat loss adjustment.

March 23, 2009

Featuring microprocessor-based, variable speed differential controller, Delta T 00 Circulator enables users to accurately calculate and adjust for heat loss because it automatically adjusts to deliver optimal heat transfer based on actual operation of system on continuing basis. Unit is suitable for use in multi-zone radiant manifolds with loop actuator and in series loop systems using zone valves. Read More

Test & Measuring Instruments, HVAC, Sensors, Monitors & Transducers

Pressure Sensors suit field blast and shock tube application.

March 20, 2009

Featuring 1 µsec of rise time and acceleration compensation, 2301C series probe-type pressure sensors are designed to measure very fast pressure transients. Hermetically sealed units have sensitivity of 0.35 pC/psi and consist of 6 different full scale range models, from 100-15,000 psi. They are operational in temperatures up to +500°F. Read More