November 3, 2009 - Combining FT Series turbine flowmeter with LinearLink(TM) Temperature Compensated Interface, FT-LD System helps user obtain precise leakage measurements for fluids such as engine oil, transmission oil, and hydraulic fluid. LinearLink TCI infers mass by density compensation, bringing cold and hot fluid volumes to standard. Regardless of fluid temperature, compensated volume of flow is converted to weight equivalent, allowing user to determine amount of leakage that has occurred.

(Archive News Story - Products mentioned in this Archive News Story may or may not be available from the manufacturer.)
Original Press release

Flow Technology, Inc.
4250 East Broadway Road
Phoenix, AZ, 85040
USA



Turbine Flow Meter Solution Provides Inferred Mass Measurements for Leak Detection


FT-LD system compensates for temperature effects on volumetric flow measurements

TEMPE, Ariz., October 21, 2009 - Flow Technology, Inc. (FTI), a leading manufacturer of precision flow measurement instruments, systems and calibrators, today announced the FT-LD (Leakage Detection) turbine flow meter system. This advanced solution offers significant improvements in flow measurement accuracy under dynamic temperature conditions. The FT-LD system provides inferred mass measurements for leakage detection by correcting for temperature effects on fluid volume.

Today's industrial companies must ensure the ruggedness and reliability of every component used in their products. For example, manufacturers of off-road equipment employ automated test stands to test torque converters for leakage prior to assembly in tractors, bulldozer, backhoes, etc. Transmission oil is measured before entering the torque converter and again after exiting. Any difference in the flow rate can be attributed to leakage in the device. This testing is complicated by the fact that fluid volume at cool temperature is not the same as at high temperatures.

Employing Flow Technology's FT Series turbine flowmeter paired with the LinearLink(TM) Temperature Compensated Interface (TCI), the FT-LD system helps users obtain precise leakage measurements for fluids such as engine oil, transmission oil and hydraulic fluid. The FT Series meter is an ideal choice when high accuracy, compact size and fast response are critical. The LinearLink TCI is a sophisticated electronics platform for flow meter linearization, viscosity correction and density compensation.

For leakage measurement, FT Series turbine flow meters are installed in series on a test stand fixture with the inlet meter located downstream of the device-under-test (DUT) and the outlet meter positioned upstream of the device. The system is then pressurized with the application fluid and the DUT is run through pre-programmed tests to evaluate its overall performance.

The LinearLink TCI infers mass by density compensation, essentially bringing the cold and hot fluid volumes to a standard. Regardless of the fluid temperature, the compensated volume of flow is converted to a weight equivalent-allowing the user to determine the amount of leakage that has occurred during a test procedure. Fluid leakage rates are calculated by subtracting the outlet mass flow rate from the inlet mass flow rate.

For more information about the FT-LD system, please visit http://www.ftimeters.com.

About Flow Technology, Inc.

With 50+ years of flow measurement experience, Flow Technology, Inc. maintains the highest standards of quality in its design, manufacturing and service. Its product line includes a wide range of turbine, positive displacement, electromagnetic, and clamp-on ultrasonic flow meters; flow calibrators; flow controllers; and ancillary electronics. Typical applications are found in the aerospace, automotive, industrial, metrology, oil & gas and sanitary fields. In addition, the company maintains one of the world's largest primary standard flow meter calibration laboratories, and provides complete flow meter calibration, service and repair. Flow Technology, Inc. is registered to ISO 9001, accredited by NVLAP, and has calibration conformance to MIL-STD-45662A and ANSI Z 540. Visit them at www.ftimeters.com.
Print Story
Print | 
Email |  Comment   Share  
Contacts: View detailed contact information.


 

Post a comment about this story

Name:
E-mail:
(your e-mail address will not be posted)
Comment title:
Comment:
To submit comment, enter the security code shown below and press 'Post Comment'.
 



 See related product stories
More .....
<!-- PNA - News | PNACON |  18860 -->
Don’t hunt for stories like this.
Let Test & Measuring Instruments
Product News Come to You!
Get a Free Subscription
to Product News Alerts.
-- IMT - News | IMTREG2 |  18716 --
Start Your Free
Subscription to
Industry Market Trends.
 See more product news in:
Test and Measuring Instruments
 More New Product News from this company:
Data Analysis Software records vessel fuel consumption data.
Electromagnetic Flow Meters utilize Faraday Principle.
Electromagnetic Flow Meters suit sanitary applications.
Electromagnetic Flow Meters range from 1-16 in.
More ....
 Tools for you
Watch Company 
View Company Profile
Company web site
More news from this company
E-Mail Story
Save Story
Search for suppliers of
Volumetric Flowmeters
Turbine Flowmeters
Join the forum discussion at:
Tools of the Trade


Home  |  My ThomasNet News®  |  Industry Market Trends®  |  Submit Release  |  Advertise  |  Contact News  |  About Us
Brought to you by Thomasnet.com        Browse ThomasNet Directory

Copyright © 2013 Thomas Publishing Company. All Rights Reserved.
Terms of Use - Privacy Policy



Error close

Please enter a valid email address