Triple Quadrupole GC/MS delivers femtogram-level sensitivity.

Print | 
Email |  Comment   Share  
August 12, 2008 - Featuring heated monolithic gold-plated hyperbolic quartz quadrupole analyzer, Model 7000A detects 100 fg of OFN on column at greater than 100:1 signal-to-noise ratio in MS/MS mode using Autotune parameters. Autotune program tunes source, mass analyzer and detector for ion transmission, mass axis calibration, mass resolution, and detector gain versus voltage. It has high-temperature solid inert ion source, Triple-Axis Detector, and gain calibration that corrects tune file for detector age.

(Archive News Story - Products mentioned in this Archive News Story may or may not be available from the manufacturer.)
Original Press release

Agilent Technologies, Inc.
5301 Stevens Creek Blvd.
Santa Clara, CA, 95051
USA



Agilent Technologies Introduces Triple Quadrupole Gas Chromatograph/Mass Spectrometer


Reliability of Best-Selling GC/MSD Extended to Analysis of More-Complex Samples at Lower Levels

DENVER, ASMS 2008, June 2, 2008

Agilent Technologies Inc. (NYSE: A) chose the American Society for Mass Spectrometry conference to introduce its 7000A triple quadrupole gas chromatograph/mass spectrometer (GC/MS/MS), designed to make high-end performance accessible to a wide range of commercial and government users.

"This new platform brings the proven ruggedness of our best-selling Agilent 5975C single quadrupole GC/MSD to a triple quadrupole system, suited for lower levels of detection and dirtier matrices," said Chris Toney, Agilent vice president and general manager, GC/MS and ICP-MS. "Users no longer have to make do with research instruments adapted for their needs. We designed the Agilent 7000A GC/MS/MS from the ground up for routine, high-performance, high-throughput operation."

At ASMS, Agilent emphasized that many of its current mass spectrometers are "smashing sensitivity barriers." The 7000A supports this position by delivering femtogram-level sensitivity. For example, the system will detect 100 fg of OFN on column at greater than 100:1 signal-to-noise ratio in MS/MS mode using Autotune parameters. This performance was verified at the end-user site on installation.

Agilent's proprietary Autotune program tunes the source, mass analyzer and detector for ion transmission, mass axis calibration, mass resolution and detector gain versus voltage. Autotune settings are saved with the method for repeatable method performance.
Mass range is 1050 u, and the fast Multiple Reaction Monitoring (MRM) speed of 500 per second enables users to determine more compounds per ion group than with comparable instruments.

While the Agilent 7000A GC/MS/MS is a new instrument, its core components are based on proven designs of the Agilent 5975C GC/MSD.

Like the 5975C, the reliability of the 7000A is anchored by Agilent's proprietary, well-proven heated monolithic gold-plated hyperbolic quartz quadrupole analyzer. The one-piece quadrupole can be heated to 200 degrees Celsius with no detectable dimensional change, remaining highly stable and clean even with high-boiling, dirty samples. Time-consuming cleaning of quadrupoles is not required, and Agilent GC/MS systems hold highly stable tunes and methods for long intervals. This stability also makes the Autotune function perform extremely well.

System cleaning is further reduced by the proprietary capillary flow, technology-based backflush function of Agilent's GC system, greatly reducing post-run bakeout time. This also reduces chemical background, extends column life and contributes to the outstanding sensitivity of the 7000A.

"Existing GC/MSD workflows can be maintained in many cases," Toney added. "The ideal candidate is someone using a GC/MSD in Selected Ion Monitoring mode, who sees the benefits of additional sensitivity and selectivity. The transition from single to triple quad in this case is easy."

The 7000A also shares Agilent's proprietary high-temperature solid inert ion source with the popular 5975C, further contributing to the system's outstanding sensitivity. The well-proven source is programmable up to 350 degrees Celsius to provide excellent response for active compounds and late eluters. High temperature also means much less frequent cleaning, reducing labor requirements and increasing uptime. The source's dual filament design further extends maintenance intervals.

The system's high performance Triple-Axis Detector provides ultra-low neutrals noise and is designed for long life and high linearity. Gain calibration corrects tune file for detector age, allowing for repeatable long-term method performance.

The Agilent 7000A GC/MS/MS runs on MassHunter Workstation software, the powerful, intuitive system for instrument control, data acquisition, qualitative and quantitative data analysis, and reporting. Agilent recently announced that MassHunter Workstation is being designed to support all Agilent GC/MS and LC/MS systems.
For more information on the new Agilent 7000A triple quadrupole GC/MS, please visit www.chem.agilent.com.

About Agilent Technologies

Agilent Technologies Inc. (NYSE: A) is the world's premier measurement company and a technology leader in communications, electronics, life sciences and chemical analysis. The company's 19,000 employees serve customers in more than 110 countries. Agilent had net revenues of $5.4 billion in fiscal 2007. Information about Agilent is available on the Web at www.agilent.com.


Print | 
Email |  Comment   Share  
Contacts: View detailed contact information.


 

Post a comment about this story

Name:
E-mail:
(your e-mail address will not be posted)
Comment title:
Comment:
To submit comment, enter the security code shown below and press 'Post Comment'.
 



 See related product stories
More .....
 Newsletters
Industry Market Trends
Has Got It
  • Latest developments
  • Trends
  • Best practices
  • Opinions & Commentary
Get Ahead. Get IMT.
Subscribe Free Today
Subscribe   View Sample

Your Gateway to a Fast Changing World
Product News Alerts
Receive similar stories and other customized news to keep you in the know on the products shaping industry.
Subscribe Free Today
Subscribe   View Sample
 See more product news in:
Laboratory and Research Supplies and Equipment
Test and Measuring Instruments
 More New Product News from this company:
Oscilloscope Software provides inter-chip compliance testing.
3D EM Simulation Software is optimized for speed.
Wireless Communications Test Set aids R/D engineers.
Tunable Laser Module aids optical component characterization.
Logic Analyzer offers 1.4-Gbps state mode option.
More ....
 Other News from this company:
Agilent Technologies' Electronic Measurement Products Score Highest in Quality Study
Agilent Technologies Introduces Innovative Multi-Measurement Signal Analyzer Capability for Wireless R&D
Agilent Technologies Adds Arbitrary Waveform Generation to InfiniiVision 3000 X-Series Oscilloscopes
Agilent Technologies Meets Test Platform Approval Criteria for Its LTE Conformance Test Solution
Agilent Technologies Offers Free WLAN, App for 34972A Data Acquisition Unit
More ....
 Tools for you
Watch Company 
View Company Profile
Company web site
More news from this company
E-Mail Story
Save Story
Search for suppliers of
Gas Chromatograph-Mass Spectrometers (GC/MS) Combined
Join the forum discussion at:
Tools of the Trade


Home  |  My ThomasNet News®  |  Industry Market Trends  |  Submit Release  |  Advertise  |  Contact News  |  About Us
Brought to you by Thomasnet.com        Browse ThomasNet Directory

Copyright © 2012 Thomas Publishing Company
Terms of Use - Privacy Policy