July 12, 2005 - Designed to verify and restore angular alignment of turret press punching stations, Pilot(TM) Tool Calibration System consists of matched set of upper and lower interlocking components loaded into machine's turret upper and lower chambers. It operates in Verification and Alignment modes and features tri-color indicator lights to warn when system is not aligned, aligned angularly and concentrically within 0.012 in., or aligned angularly and concentrically within 0.0003 in.

(Archive News Story - Products mentioned in this Archive News Story may or may not be available from the manufacturer.)
Original Press release

Mate Precision Tooling
1295 Lund Boulevard
Anoka, MN, 55303
USA



Mate Precision Tooling Introduces The Mate Pilot(TM) -- A New Tool Calibration System For Aligning And Verifying CNC Punch Press Turret Precision


Call 1-800-328-4492 For FREE Brochure

Anoka, Minnesota: Mate Precision Tooling leads the punching industry with another "first" - the Mate Pilot(TM) Tool Calibration System. Designed to verify and restore the angular alignment of punching stations of a turret press, this system is highly accurate and easy to use.

The Pilot Tool Calibration System provides punch press users with an effective and reliable means for maintaining top punch press performance while safeguarding tooling and eliminating scrapped parts because of turret alignment problems.

System Ensures Precision Concentric And Angular Tool Component Alignment

Consisting of a matched set of upper and lower interlocking components, which are loaded into the machine's turret upper and lower chambers, the system operates in two modes:

Verification mode - Confirms the precise concentric and angular alignment of the punch press turret to maintain high quality piece part production and maximum tool life.

Alignment mode - Restores the concentric and angular alignment of each station with the same precision as the initial machine installation.

System Is Easy And Fast To Use

Simply install the two halves of the calibration instrument into the press turret station to be aligned. Then rotate the turret to position the station to be aligned under the machine's ram. Tighten the integral adjustment handle which draws the two halves of the calibration instrument together.

As this engagement occurs, the interlocking design of the interface causes the loosened die holder assembly to draw precisely together into concentric and angular alignment relative to the upper bore of the turret.

During this process, tri-color indicator lights on the top of the instrument signal alignment. When the indicator shows: Red - system is not yet aligned; Yellow - system is aligned angularly and concentrically within 0.012 inch / 0.030 mm; Green - system is aligned angularly and concentrically within 0.0003 inch / 0.008 mm (recommended when punching materials 0.078 inch / 2.00 mm thickness or less).

High Precision Components Ensure Accuracy, Long Life

Like Mate's high precision, long-life tooling, the Mate Pilot Tool Calibration System is quality manufactured to provide years of alignment service thereby ensuring top punch press and tool performance. Each calibration instrument is machined from a single piece of the highest quality tool steel. Upper and lower halves of the instrument are separated near the end of the production process and just prior to the installation of hardware. This ensures that the two components are a precisely matched set with high accuracy, thereby eliminating any possibility of cumulative tolerances adversely affecting instrument accuracy.

Mate Pilot Tool Calibration Sets Available For Amada And Finn Power Presses

Mate Pilot Tool Calibration sets are available for Amada thick turret and Finn Power presses in: A Station ˝ inch (12.70 mm), B Station 1-1/4 inch (31.80 mm), C Station 2 inch (50.80 mm), D Station 3-1/2 inch (88.90) and E Station 4-1/2 inch (12.70 mm). Accessory kits consisting of alignment and adjusting bars are required that work with any station size.

For a FREE Mate Pilot(TM) Tool Calibration Tool system brochure, call 1-800-328-4492.

See at mate.com/pilot

Email: marketing@mate.com

Or write to MATE PRECISION TOOLING, 1295 Lund Boulevard, Anoka, Minnesota 55303. USA and Canada, Fax 1-800-541-0285. Outside USA and Canada, call 1-763-421-0230 Fax 1-763-421-0285.
Print | 
Email |  Comment   Share  
Contacts: View detailed contact information.


 

Post a comment about this story

Name:
E-mail:
(your e-mail address will not be posted)
Comment title:
Comment:
To submit comment, enter the security code shown below and press 'Post Comment'.
 



 Newsletters
Industry Market Trends
Has Got It
  • Latest developments
  • Trends
  • Best practices
  • Opinions & Commentary
Get Ahead. Get IMT.
Subscribe Free Today
Subscribe   View Sample

Your Gateway to a Fast Changing World
Product News Alerts
Receive similar stories and other customized news to keep you in the know on the products shaping industry.
Subscribe Free Today
Subscribe   View Sample
 See more product news in:
Machinery and Machining Tools
 More New Product News from this company:
Lubrication Pads maintain punched parts edge quality.
Deburring Tool eliminates need for secondary operations.
High Precision Grinder facilitates punch and die maintenance.
Indexible Multi-tool achieves any angle setting on workpiece.
Turret Tooling Storage Cabinets facilitate accelerated setup.
More ....
 Other News from this company:
Mate Precision Tooling to Showcase "Solutions Possible" at Fabtech 2011, Booth 1330 See Special Application Tooling, Including Mate's Easymark(TM), Easysnap(TM), Snaplock(TM) and More
Mate Precision Tooling to Exhibit UltraŽ Fully Indexable Multi Tool, ULTRAFORM(TM) Holders, and Rollerball Deburr(TM) Tooling at the China International Machine Tool Show Booth W4-A105
Frank Baeumler Appointed Vice President of Business Development for Mate Precision Tooling
Mate Precision Tooling Opens Shanghai China Office Wei Sun Appointed China Sales Manager
Imperial Systems, Inc. Offers Replacement Dust Collector Cartridge Filters for all Brands of Dust Collectors!
More ....
 Tools for you
Watch Company 
View Company Profile
Company web site
More news from this company
E-Mail Story
Save Story


Home  |  My ThomasNet News®  |  Industry Market Trends  |  Submit Release  |  Advertise  |  Contact News  |  About Us
Brought to you by Thomasnet.com        Browse ThomasNet Directory

Copyright © 2012 Thomas Publishing Company
Terms of Use - Privacy Policy