Temperature Transmitter has universal input options.
Temperature Transmitter has universal input options.

Click Here to Enlarge Picture

September 16, 2008 - Concentrating up to 32 signals onto single twisted wire pair, TCS Temperature Concentrator System can be set to accept RTD (2-, 3-, 4-wire, Pt, Cu, Ni), thermocouple (J, K, E, T, R, S, N, B, C), resistance/potentiometer (0-4,000 ohms), and -50 to 1,000 mV inputs. It utilizes HART, or MODBUS RTU with converter module, for communication from field to control room. Measuring less than 5 in. wide, loop-powered TCS's operating parameters can be configured from any HART-based system.

(Archive News Story - Products mentioned in this Archive News Story may or may not be available from the manufacturer.)
Original Press release

Moore Industries International, Inc.
16650 Schoenborn St.
North Hills, CA, 91343
USA



Multi-Channel Temperature Transmitter Delivers Low Cost Per Point Measurements


NORTH HILLS, CA-The TCS Temperature Concentrator System from Moore Industries substantially reduces the cost of transmitting multiple temperature sensor measurements by concentrating up to 32 signals onto a single twisted wire pair. The system provides a precision measurement at less than 25 percent the cost of using comparable stand-alone smart temperature transmitters.

The TCS accepts any combination of RTD, T/C, mV and resistance/potentiometer signal inputs, converts the inputs to the HART digital communications protocol, and transmits the data long distances from the field to the control room on an economical HART digital data link over a twisted wire pair. All process, status and diagnostic information can then be accessed by a HART-based control system.

"As we all know, manufacturing companies are continuously looking to reduce costs. To do this, some are moving away from stand-alone transmitters to lower cost per point temperature bricks," says Tina Lockhart, Moore Industries' Director of Engineering. "Saving real estate also equates to reduced overall costs. At less than 5 inches wide, each of our TCS modules will handle 16 measurements in a fraction of the space required by stand-alone transmitters."

In addition to savings realized in instrument and space costs, the TCS uses HART--or MODBUS RTU with a converter module--for communication from the field to the control room. One twisted wire pair replaces expensive dedicated wires. The TCS, being a loop-powered device, eliminates the need to send power wiring out to the field as well.

Using HART, maintenance personnel can access programming and status information for each TCS channel from the control room, or from any termination point using a standard HART hand-held communicator. There's no need to send someone to remote sites.

"In developing the TCS, our greatest challenge was to provide our customers with the cost savings they want, yet still maintain the full functionality and exceptional product performance they expect from a Moore Industries temperature transmitter," Lockhart adds.

When used with the optional HMC HART-to- MODBUS Converter, the HMC transmits the HART data as a MODBUS RTU signal, which interfaces with any MODBUS RTU-based PC, PLC or control system.

Substantially Reduces Hardware, Wire, and Installation Costs. The TCS eliminates the need to install a dedicated transmitter and twisted wire pair (or expensive sensor extension wires) for each measurement.

Universal Input Options. The TCS can be set to accept RTD (2-, 3-, 4-wire; Pt, Cu, Ni); thermocouple (J, K, E, T, R, S, N, B, C); resistance/ potentiometer (0-4000 ohms); and millivolt (-50 to 1000mV) inputs. By using Moore Industries' free Intelligent PC Configuration Software, custom input linearization can be defined for any input.

HART and MODBUS RTU Communications. These standard communication protocols allow easy interface to a wide range of DCS, PLC and computer-based networks.

Fault Alarms. The HMC can be programmed via the PC software to provide two relay outputs. The relays can be set to send a master alarm when the HMC detects one, any, or all of the following fault conditions within the system: No HART signal; broken wire; hardware error; bad configuration; input saturated; and input out of table range. The alarms can be set with a time delay, which specifies how long the alarm condition needs to exist before the alarm trips. Failsafe and Non-Failsafe alarm action is also configurable.

Versatile Programming. TCS operating parameters can be configured from any HART-based system or, using a standard HART hand-held, from anywhere along the twisted wire pair. The TCS can also be configured using Moore Industries' free Intelligent PC Configuration Software.

For more information, contact:
Moore Industries-International, Inc.
16650 Schoenborn St.
North Hills, CA 91343, U.S.A
Telephone: (818) 894-7111
FAX: (818) 891-2816
E-mail: info@miinet.com
Web Site: www.miinet.com
Print Story
Print | 
Email |  Comment   Share  
Contacts: View detailed contact information.


 

Post a comment about this story

Name:
E-mail:
(your e-mail address will not be posted)
Comment title:
Comment:
To submit comment, enter the security code shown below and press 'Post Comment'.
 



 See related product stories
More .....
<!-- PNA - News | PNACON |  18860 -->
Don’t hunt for stories like this.
Let Sensors, Monitors & Transducers
Product News Come to You!
Get a Free Subscription
to Product News Alerts.
-- IMT - News | IMTREG2 |  18716 --
Start Your Free
Subscription to
Industry Market Trends.
 See more product news in:
Sensors, Monitors and Transducers
 More New Product News from this company:
Safety Relay Module adds alarm contacts to safety processes.
Wireless Network Module sends signals between remote sites.
Process Control System serves as single or dual MODBUS master.
Fieldbus Power Supply suits non-incendive applications.
Signal Conditioners deliver up to 4 I/O channels.
More ....
 Other News from this company:
STA Safety Trip Alarm from Moore Industries SIL 2 and SIL 3 Certified to IEC 61508 by Exida
Moore Industries Honored with Manufacturing Leadership Award
Moore Industries' I/O Solution Helps OCWA Provide Clean, Safe Drinking Water to Central New York
Moore Industries Voted Top in Signal Conditioners in 2011 Control Magazine Readers' Choice Awards
Watch the WORM Flexible Temperature Sensor Technology Demo from Moore Industries
More ....
 Tools for you
Watch Company 
View Company Profile
Company web site
More news from this company
E-Mail Story
Save Story
Search for suppliers of
Temperature Transmitters
Join the forum discussion at:
Wired In


Home  |  My ThomasNet News®  |  Industry Market Trends®  |  Submit Release  |  Advertise  |  Contact News  |  About Us
Brought to you by Thomasnet.com        Browse ThomasNet Directory

Copyright © 2013 Thomas Publishing Company. All Rights Reserved.
Terms of Use - Privacy Policy



Error close

Please enter a valid email address