Sorbent Panel Assemblies trap odors, gases, and particulate.

Press Release Summary:




CamsorbT CF4A adsorber modules are suited for commercial, industrial, and medical facilities where control of gaseous contaminants or odors may be of concern. Each unit uses 12 Camsorb CF 1 in. panels filled with loose-fill or application-specific sorbent media. Sorbent section is sandwiched between 2 particulate filter frames that allow installation of various combinations of prefilters and ASHRAE grade final filters. Assemblies may be stacked up to 6 units high.



Original Press Release:



New Camsorbt CF4A Built-Up Bank Assemblies Provide High-Capacity Control of Odors, Gases And Particulates



Riverdale, N.J., April 2005 - New "CamsorbT" CF4A built-up bank sorbent panel assemblies from Camfil Farr provide high-capacity control of odors, gases and particulate contaminants. Applications include commercial and industrial properties, medical facilities, and other buildings where the control of gaseous contaminants or odors may be a concern. The modular assemblies may also be used to reduce outside air requirements by increasing recirculated air, thus saving energy during the heating and cooling seasons.

Each CF4A adsorber module assembles into a built-up bank of gaseous and particulate filtration with 85 pounds of adsorbent per 2000 cfm, a prefilter of any depth and a final filter of any depth. Adsorber sections feature corrosion-resistant, 16-gauge galvanized steel with integral tracks and an easy-to-access design that facilitates installation and servicing of adsorber panels. Each full-size unit uses 12 Camsorb CF one-inch panels, which come filled with loose-fill sorbent media or a choice of application-specific sorbents. The sorbent section is sandwiched between two particulate filter holding frames that allow installation of various combinations of prefilters and ASHRAE grade final filters.

The Camsorb CF4A assemblies may be stacked up to six units high (12 ft.) without modifications. Resistance to airflow is also minimal at 0.35" w.g. at 500 fpm (2000 cfm per full-size module), for energy-efficient performance. For downloadable product information, go to: filterair.info/literature/Files/2106%2Epdf.

For further information, call (866) 4CAMFIL, fax (973) 616-7771, or write to Camfil Farr Marketing Dept., One North Corporate Dr., Riverdale, NJ 07457; e-mail literature@camfilfarr.com, Web site www.camfilfarr.com.

In Canada, call (866) 4CAMFIL, fax (450) 662-6035; or write to Camfil Farr, 2785 Frances Hughes Ave., Laval, Quebec H7L 3J6; e-mail literature@camfilfarr.com, Web site www.camfilfarr.com.