ThomasNet Home   |   Promote Your Business
Home  |   My ThomasNet News®  |   Industry Market Trends  |   Submit Release  |   Advertise  |   About Us May 26, 2012  

Self-Conditioning Flow Meter helps FPSO vessels shed weight.

Print | 
Email |  Comment   Share  
Self-Conditioning Flow Meter helps FPSO vessels shed weight.
Self-Conditioning Flow Meter helps FPSO vessels shed weight.

Click Here to Enlarge Picture

March 24, 2009 - V-Cone® FPSO Flow Meter employs differential pressure (DP) flow measurement technology with built-in flow conditioning that reduces upstream/downstream straight pipe run requirements. Maintaining accuracy of +0.5% and repeatability of +0.1% over entire range, this product is suited for top-side and sub-sea FPSO applications measuring liquid, steam, or gas. It supports line sizes from 0.5-120 in., features 10:1 turndown ratio, and has no moving parts.

(Archive News Story - Products mentioned in this Archive News Story may or may not be available from the manufacturer.)
Original Press release

McCrometer, Inc.
3255 W. Stetson Ave.
Hemet, CA, 92545
USA



V-Cone Flow Meter Helps FPSO Vessels Shed Weight and Save Space for Big Cost Savings


Hemet, CA-February 25, 2009-McCrometer announces the newest V-Cone® FPSO Flow Meter which will be exhibited at the Offshore Technology Conference (OTC), May 4-7, Reliant Center, Pavilion Booth 8127. The V-Cone Flow Meter offers proven differential pressure (DP) flow measurement technology with built-in flow conditioning that reduces upstream/downstream straight pipe run requirements by up to 70% or more. This significant reduction in pipe requirements adds up to cost savings in materials and installation labor while reducing overall weight and saving valuable deck space. Using less pipe and thereby reducing weight also can simplify vessel balancing, which makes it easier to find the optimal location for meter installation.

The effects of swirl and other pipeline disturbances caused by nearby valves or elbows often hamper flow meter performance by negatively affecting measurement accuracy and repeatability. For this reason, most flow meter installations require 10 to 40 straight pipe diameters upstream from the meter and 5 or more straight pipe diameters downstream, to smooth the liquid flow profile prior to measurement. With built-in flow conditioning, the V-Cone Flow Meter needs only 0 to 3 straight pipe diameters upstream and 0 to 1 downstream to operate effectively and maintain accuracy.

The V-Cone's unique self-conditioning design provides an extremely stable flow profile delivering high accuracy of +0.5% and repeatability of +0.1% over the entire range. The versatile V-Cone is ideal for both top-side and sub-sea FPSO applications measuring liquid, steam or gas and supporting line sizes from 0.5 to 120 inches with an unmatched 10:1 turndown ratio for wide range-ability.

Petroleum production engineers can depend on the V-Cone for an exceptionally low cost of ownership because the meter has no moving parts. The V-Cone requires virtually no maintenance or recalibration over an unprecedented long life, typically exceeding 25 years. With low permanent head loss, the V-Cone reduces the cost of ownership by minimizing energy requirements. For critical surge control compressor applications, the V-Cone exhibits quick reaction time due to the low noise to signal ratio compared to other differential pressure technologies. With a feedback control loop the fast reaction of the V-cone can help avoid compressor damage and loss of production.

About McCrometer
McCrometer's advanced liquid, steam and gas flow measurement solutions solve complex challenges in Municipal/Industrial Water & Wastewater, Oil & Gas, Process Control & Plant, Electric Power Generation, Institutional Facilities and Agriculture. The company's products and systems are found in thousands of installations worldwide. Its products and systems meet many of the world's most demanding industrial, safety and quality standards. Visit us on the web at www.mccrometer.com

Company Contact: Jennifer Kerckhoff (281) 998-0449
Company Address: 3255 W Stetson Ave, Hemet, CA 92545
Web: http://www.mccrometer.com
Tel: 800-220-2279 Tel: 951-652-6811 Fax: 951-652-3078
Print | 
Email |  Comment   Share  
Contacts: View detailed contact information.


 

Post a comment about this story

Name:
E-mail:
(your e-mail address will not be posted)
Comment title:
Comment:
To submit comment, enter the security code shown below and press 'Post Comment'.
 



 See related product stories
More .....
Don’t hunt for stories like this.
Let Sensors, Monitors & Transducers
Product News Come to You!
Get a Free Subscription
to Product News Alerts.
Start Your Free
Subscription to
Industry Market Trends.
 See more product news in:
Sensors, Monitors and Transducers
 More New Product News from this company:
Direct Mount Flowmeter features direct mount configuration.
Telemetry System supports irrigation applications.
Insertion Flow Meter provides bi-directional measurement.
Electromagnetic Flow Meter supports hot tap installation.
Inline Flow Meter targets water filtration plants.
More ....
 Other News from this company:
McCrometer to Feature FPI Mag(TM) Flow Meter at AWWA ACE12
McCrometer Presents Advanced Offshore Flow Measurement Solutions at OTC 2012
McCrometer Installs New Wet Gas Test Stand to Support Energy Industry R&D Programs
Space-Saving V-Cone Flow Meter Cuts WAG System Installed & Operational Costs
FPI Mag(TM) & V-Cone® Flow Meters Provide Accurate Measurement with Low Maintenance and Life-Cycle Costs
More ....
 Tools for you
Watch Company 
View Company Profile
Company web site
More news from this company
E-Mail Story
Save Story
Search for suppliers of
Differential Pressure Flowmeters
Join the forum discussion at:
Tools of the Trade


Home  |  My ThomasNet News®  |  Industry Market Trends  |  Submit Release  |  Advertise  |  Contact News  |  About Us
Brought to you by Thomasnet.com        Browse ThomasNet Directory

Copyright © 2012 Thomas Publishing Company
Terms of Use - Privacy Policy



Error close

Please enter a valid email address