June 15, 2010 - Supplied in standard OEM package measuring 2.2 x 3.9 x 0.50 in., model 410-XSC single-channel capacitance amplifier is compatible with new and existing non-contact displacement and gap probes. Open frame promotes flexibility, and optional compact enclosure with power supply is available. For applications requiring use of multiple sensors, boards can be rack-mounted and optionally connected to Capacitec Bargrafx(TM) LabView®-based data acquisition and display software.

(Archive News Story - Products mentioned in this Archive News Story may or may not be available from the manufacturer.)
Original Press release

Capacitec, Inc.
87 Fitchburg Rd., P.O. Box 819
Ayer, MA, 01432
USA



Capacitec Launches Nanometer Resolution Single Channel Non-Contact Displacement Amplifier in a Standard OEM Package


Ayer, Mass., USA - Capacitec, Inc. (Capacitec), a leading ISO9001: 2008 certified designer and manufacturer of non-contact capacitive displacement, gap and parallelism sensing systems, bore gauges, data acquisition systems, linearization and display software, has announced the launch of the model 410-XSC, a new family of single channel, stand-alone capacitance amplifiers with superior stability, resolution, signal-to-noise ratio and bandwidth in a standard OEM package.

Measuring just 55 x 100 x 12.7mm (2.2 x 3.9 x 0.50 in.), the compact Capacitec model 410-XSC amplifier is designed to be compatible with new and existing non-contact displacement and gap probes. It features an open frame for maximum flexibility, or optional compact enclosure with power supply, to suit a variety of measurement environments. For applications that require use of multiple sensors, the boards can be rack mounted and optionally connected to Capacitec Bargrafx(TM), a LabView® based data acquisition and display software, providing additional linearization and signal conditioning capabilities.

Because of its flexible design, the model 410-XSC can support a variety of standard and customer displacement and gap sensor signal amplification requirements, including support for very small sensors with high-displacement range and long cable lengths, as well as those with especially wide displacement and gap ranges. It is a popular choice for OEM customers with stringent high sensitivity application requirements, such as those found in nano indenters, dynamic slot die coater head air gap to metal roller parallelism measurements or similar, load frames and laser alignment mechanism monitoring.

For more information about the model 410-XSC or other products available from Capacitec, please call 978-772-6033, email sales@capacitec.com, or visit www.capacitec.com.

About Capacitec, Inc.:
Headquartered in Ayer, Massachusetts, USA, with additional operations in Creteil, France, Capacitec is an ISO9001:2008 global technology company, dedicated to advancing the capacitive principle of measurement physics to its highest level in sensor system design. The company's core competencies are the design and manufacture of non-contact capacitive displacement, gap sensors, bore gauges, parallelism and density sensors with matching capacitance amplifiers, data acquisition systems, linearization and display software. Capacitec specializes in large range, small diameter sensors that operate in severe environments, from cryogenic to +1000°C, under radiation to 1018 RADS and in strong magnetic fields to 5 Tesla. More than 25 years of successful product line history has demonstrated Capacitec's expertise across all markets, particularly within applications where traditional sensors cannot fit or survive.
Print | 
Email |  Comment   Share  
Contacts: View detailed contact information.


 

Post a comment about this story

Name:
E-mail:
(your e-mail address will not be posted)
Comment title:
Comment:
To submit comment, enter the security code shown below and press 'Post Comment'.
 



 See related product stories
More .....
Don’t hunt for stories like this.
Let Product News Come to You!
Get a Free Subscription
to Product News Alerts.
Edit Story Categories
Start Your Free
Subscription to
Industry Market Trends.
 See more product news in:
Mechanical Power Transmission
Sensors, Monitors and Transducers
 More New Product News from this company:
Sensor Systems aid in solar panel production.
More ....
 Other News from this company:
Capacitec Launches New Global Website at www.capacitec.com
Capacitec Non-Contact Gap Sensors Systems Offer Reliable Performance in Critical Aircraft Assembly and Coating Applications
Capacitec High Temperature Non-Contact Displacement Sensors Offer Performance to +1000 °C in Manufacturing and Testing Applications
More ....
 Tools for you
Watch Company 
View Company Profile
Company web site
More news from this company
E-Mail Story
Save Story
Search for suppliers of
Displacement Sensors
Capacitive Sensors
Amplifiers
Join the forum discussion at:
Tools of the Trade
Wired In


Home  |  My ThomasNet News®  |  Industry Market Trends  |  Submit Release  |  Advertise  |  Contact News  |  About Us
Brought to you by Thomasnet.com        Browse ThomasNet Directory

Copyright © 2012 Thomas Publishing Company
Terms of Use - Privacy Policy



Error close

Please enter a valid email address