ThomasNet Home   |   Promote Your Business
Home  |   My ThomasNet News®  |   Industry Market Trends  |   Submit Release  |   Advertise  |   About Us May 26, 2012  

Laser Calibration System measures at 4 m/s with 1 nm resolution.

Print | 
Email |  Comment   Share  
Laser Calibration System measures at 4 m/s with 1 nm resolution.
Laser Calibration System measures at 4 m/s with 1 nm resolution.

Click Here to Enlarge Picture

June 7, 2010 - Featuring 6 minute warm up time, Lean-Design XL-80 brings nanometer-level motion analysis to calibration, error-mapping, and compensation of laboratory equipment, semi-conductor processing machinery, CMMs, machine tools, and robots. System takes readings at 50 kHz and maintains system accuracy of ±0.5 ppm over operating range of 32-104°F. Multi-signal connector provides standard trigger signal-in for data capture, analog voltage-out facility, and optional quadrature signal output.

(Archive News Story - Products mentioned in this Archive News Story may or may not be available from the manufacturer.)
Original Press release

Renishaw, Inc.
5277 Trillium Blvd.
Hoffman Estates, IL, 60192
USA





IMTS - Lean-Design XL-80 Laser Calibration System


Lean-design XL-80 laser calibration system brings greater performance, precision, and portability to manufacturing machinery process validation

Compact system measures at 4 m/s, raises environmentally-corrected accuracy to ±0.5 ppm, warms up faster, weighs less and transports easier

Renishaw advances technology leadership in laser interferometer calibration with the "lean design" XL-80 system. The new design allows a 4X faster slew rate, 10X higher dynamic data capture rate, and industry's best total system accuracy in a smaller, lighter and more portable package. The XL-80 brings nanometer-level motion analysis to calibration, error-mapping and compensation of everything from laboratory equipment, semi-conductor processing machinery and radiosurgery tools to coordinate measuring machines, lithography equipment, advanced machine tools, robots, and assembly systems.

Meeting industry trends to high-speed machinery, higher precision and greater process control, the XL-80 increases linear measurement speed to 4m/s, while providing a resolution of 1 nm, even at top speed. Lightweight, compact packaging enables easier transport and set up, while industry's fastest warm up - less than six minutes - minimizes waits to increase available measurement time.

A new signal gain switch gives the option of 80 m linear range (such as for large aircraft profilers) or increased signal strength at shorter ranges.

System accuracy of ±0.5 ppm, best in the industry, is maintained over the full operating range of 0-40°C (32°-104°F). A new XC-80 Intelligent Sensor System maintains that accuracy against variations in temperature, pressure and humidity by updating the environment factor every seven seconds via a USB link.

The XL-80 takes readings at 50 kHZ, up from 5 kHZ for Renishaw's previous industry-standard ML10. The 10X increase in bandwidth enables capture of detailed data about small high frequency movements. Enhanced versions of Renishaw software (LaserXL(TM) and QuickviewXL(TM)) present data in easy-to-use style.

The new XL-80 system is backward compatible with optics from Renishaw's ML10 laser system, enabling thousands of current ML10 users to upgrade to the new system while retaining their investment in optics, procedures and staff training. A full range of optics enables highest precision interferometer determination of a machine's linear, angular, flatness, straightness and squareness measurements to international checking standards.

As with the ML10, all measurements are based on the wavelength of a stabilized HeNe laser source, giving users assured traceability back to internationally recognized length standards.

Advanced engineering reduces weight for the XL-80 laser unit and XC-80 compensator by 70% compared to the ML10, allowing a much smaller transport package. Combined weight is just over 3 kg, including connecting cables, power supply and sensors - about the difference between an overnight bag now and your mother-in-law's suitcase before.

In turn, other system components - such as tripod and stage - have been downsized. The smallest "wheelie case" option is now just half the size of the original ML10 "Supercase," but still carries a full linear and angular system, with available provision for a Renishaw QC10 ballbar kit. Weighing less than 17 kg, it offers superior portability to other laser systems for greater ease of travel, especially by air.

The reduced dimensions of the laser head and stage allow easy mounting on an available magnetic base for applications where tripod mounting is not convenient. The same base height and optics dimensions as the ML10 allows the XL-80 to also be placed directly on the table (without tripod stage) for coordinate measuring machine (CMM) calibration.

Faster warm-up gives highest measurement productivity. This is especially important for calibration service providers and large manufacturing organizations needing to perform measurements on multiple machines, particularly on regularly scheduled predictive/preventive maintenance programs. A new multi-signal connector facility increases XL-80 flexibility. It provides a standard trigger signal-in (for data capture), an analog voltage-out facility, and an optional quadrature signal output. Connection to a PC is now via USB, so no separate interface is required.

Renishaw laser calibration systems are the preferred choice worldwide by OEM's and end-users in research, design, manufacturing and maintenance applications. For more information on the XL-80 laser interferometer calibration system, contact Clive Warren, Business Manager-Calibration Products, Renishaw Inc. Phone 847-286-9953. Fax 847-286-9974. Email: Clive.Warren@Renishaw.com or visit www.renishaw.com/calibration.

For a detailed look at other productivity enhancements for metrology, machine tool, linear position feedback, and calibration products, visits Renishaw's web site at: www.renishaw.com


Print | 
Email |  Comment   Share  
Contacts: View detailed contact information.


 

Post a comment about this story

Name:
E-mail:
(your e-mail address will not be posted)
Comment title:
Comment:
To submit comment, enter the security code shown below and press 'Post Comment'.
 



 See related product stories
More .....
Don’t hunt for stories like this.
Let Product News Come to You!
Get a Free Subscription
to Product News Alerts.
Edit Story Categories
Start Your Free
Subscription to
Industry Market Trends.
 See more product news in:
Machinery and Machining Tools
Test and Measuring Instruments
 More New Product News from this company:
Additive Manufacturing Systems process reactive materials.
Programmable Comparative Gauge has parallel kinematic structure.
True Absolute Encoder offers FANUC serial communications.
Part Gauging System can be programmed for multiple parts.
Multiplex Assay System analyzes up to 10 targets/sample.
More ....
 Other News from this company:
Renishaw Wins Fifteenth Queen's Award for Ultra-High Accuracy Measurement System
Revolutionary Gauging System Wins Third International Award
Renishaw Announces Additional Exhibits at MACH 2012
Renishaw Opens New Subsidiary in Mexico
Renishaw to Focus on Precision Position Feedback at Drives & Controls 2012
More ....
 Tools for you
Watch Company 
View Company Profile
Company web site
More news from this company
E-Mail Story
Save Story
Search for suppliers of
Calibrators
Machine Tool Calibration Equipment
Portable Calibrators
Join the forum discussion at:
Tools of the Trade


Home  |  My ThomasNet News®  |  Industry Market Trends  |  Submit Release  |  Advertise  |  Contact News  |  About Us
Brought to you by Thomasnet.com        Browse ThomasNet Directory

Copyright © 2012 Thomas Publishing Company
Terms of Use - Privacy Policy



Error close