October 5, 2009 - Suited for measuring flow in most clean liquids and many liquids with entrained solids, CSLFC and CSLFB Ultrasonic Flow Transmitters are available with 3-wire RTD temperature output. RTD is built into transducer well, offering process temperature measurement and flow measurement in one instrument. Made of cast brass, CSLFB models are designed for full scale flow ranges from 15-400 gpm in ¾-3 in. pipe, while CSLFC units measure flows to 4,000 gpm in 4-10 in. pipe.

(Archive News Story - Products mentioned in this Archive News Story may or may not be available from the manufacturer.)
Original Press release

Clark Solutions
10 Brent Dr.
Hudson, MA, 01749
USA



Clark Ultrasonic Flow Transmitters Feature Optional Temperature Output


Clark Solutions CSLFC and CSLFB Ultrasonic Flow Transmitters are ideal for measuring flow in most clean liquids and many liquids with entrained solids. Now available with Optional Three-Wire RTD Temperature Output, these instruments are particularly suited to monitoring flow rates of chilled or heated water for control or as part of a green technology program as well as in municipal, process, and industrial systems. All Clark Ultrasonic Flow Transmitters free users from having to calibrate the transmitter to fluid temperature, viscosity, or density making them very easy to deploy and very reliable.

Hudson, MA - Clark Solutions-announces the availability of a Three-Wire RTD Temperature Output on both CSLFB and CSLFC Ultrasonic Flow Transmitters. The RTD is built in to one of the flow transmitters transducer wells offering the convenience of accurate process temperature measurement and flow measurement in one instrument. These transmitters are ideal for measuring flow rates and temperature of acoustically conductive liquids, including most clean liquids and many liquids with entrained solids. Model CSLFB Ultrasonic Flow Transmitters are designed for full-scale flow ranges from 15 to 400 GPM in ¾" to 3" pipe. They are a rugged cast brass design and have an accuracy of ±0.75% F.S. CSLFC Ultrasonic Flow Transmitters are designed for flows to 4000 GPM in 4" to 10" pipe, feature no moving parts, excellent long-term stability, no pressure drop, broad fluid compatibility, and high accuracy (± 0.75% of full scale) at a lower cost than similar instruments. Wetted materials include ULTEM® encapsulated ultrasonic transducers with a choice of EPDM, Buna-N, Neoprene(TM), FKM, or other seals and epoxy coated, Schedule 40 carbon steel pipe body material.

Available for purchase online at http://www.clarksol.com/html/cslfb.cfm , these transmitters are offered at approximately half the cost of similar instruments. Model CSLFB transmitters are available starting at $577, FOB Hudson MA. Model CSLFC transmitters start at $1584, FOB Hudson MA.

At the heart of Clark Ultrasonic Flow Transmitters is a proprietary mixed signal ASIC, (Application Specific IC,) which allows sophisticated timing, control and transducer drive circuitry to be combined on a single integrated circuit. The ASIC uses a special algorithm that is an improvement upon the standard single-path measurement technique. Clark ultrasonic transmitters utilize the "sing around" method, where the ultrasonic transducer alternates between transmitting and receiving to measure differences in flight time between upstream and downstream transmissions. The flight time of the sound pulse from the transmitting transducer to the receiving transducer will be shortened if the pulse is launched in the direction of flow, and increased if launched opposite to the direction of flow. By alternating the transmitting and receiving transducers, the difference in these transit times can be used to calculate the velocity of the flow, which when multiplied by the area of the pipe results in a measure of volumetric flow rate. The primary advantage of the Sing Around method is that the velocity of the fluid is being measured independent of the relative speed of sound in that given fluid. The output of Clark transmitters is also unaffected by changes in fluid temperature, density and viscosity.

Clark Solutions has a fifty-year history of providing unique solutions to the measurement, control, and monitoring of pressure, flow, and level in liquids and gases. Located in Hudson, Massachusetts, the company offers instrumentation, valves, and pumps to record, monitor, and control flow, velocity, pressure, temperature, humidity, level, gas concentration, and other properties. For more information contact Clark Solutions, 10 Brent Drive, Hudson, MA 01749, Tel. 978-568-3400, Fax. 978-568-0060, or visit our web site at http://www.clarksol.com.

WEB PAGE: http://www.clarksol.com/html/cslfb.cfm

IMAGE URL: http://clarksol.com/im
Print | 
Email |  Comment   Share  
Contacts: View detailed contact information.


 

Post a comment about this story

Name:
E-mail:
(your e-mail address will not be posted)
Comment title:
Comment:
To submit comment, enter the security code shown below and press 'Post Comment'.
 



 See related product stories
More .....
 Newsletters
Industry Market Trends
Has Got It
  • Latest developments
  • Trends
  • Best practices
  • Opinions & Commentary
Get Ahead. Get IMT.
Subscribe Free Today
Subscribe   View Sample

Your Gateway to a Fast Changing World
Product News Alerts
Receive similar stories and other customized news to keep you in the know on the products shaping industry.
Subscribe Free Today
Subscribe   View Sample
 See more product news in:
Sensors, Monitors and Transducers
Test and Measuring Instruments
 More New Product News from this company:
Miniature Diaphragm Pumps offer single or dual pump heads.
Vortex Flow Transmitters offer flow ranges from 0.3-22 gpm.
Energy Monitor suits solar, submetering, energy transfer systems.
Diaphragm Pumps come in single and dual head models.
Compact Rotary Vane Pumps are suited for tight locations.
More ....
 Tools for you
Watch Company 
View Company Profile
Company web site
More news from this company
E-Mail Story
Save Story
Search for suppliers of
Flow Transmitters
Ultrasonic Transmitters
Temperature Transmitters
Join the forum discussion at:
Wired In


Home  |  My ThomasNet News®  |  Industry Market Trends  |  Submit Release  |  Advertise  |  Contact News  |  About Us
Brought to you by Thomasnet.com        Browse ThomasNet Directory

Copyright © 2012 Thomas Publishing Company
Terms of Use - Privacy Policy