ThomasNet News Logo
Sign Up | Log In | ThomasNet Home | Promote Your Business

Flow Meter offers high accuracy in dirty gas measurement.

Print Story
Print | 
email story Email |  Comment Comment   Share facebook twitter reddit StumbleUpon Delicious Digg  
February 8, 2007 - Conforming to API 22.2 Testing Protocol, Wafer-Cone® coal-bed methane gas flow meter features built-in flow conditioning to achieve accuracy of ±0.5% with repeatability of ±0.1%. Operating over flow range of 10:1, differential pressure flow meter is designed for liquid or gas service in line sizes from 0.5-6 in., and is suitable for small process lines or plant infrastructure tasks. Space-saving unit eliminates need for extensive up/down stream straight pipe runs.

(Archive News Story - Products mentioned in this Archive News Story may or may not be available from the manufacturer.)
Original Press release

McCrometer, Inc.
3255 W. Stetson Ave.
Hemet, CA, 92545
USA



New Coal-Bed Methane Gas Flow Meter Offers High Accuracy in Dirty Gas Measurement


Wafer-Cone Flow Meter Approved by BLM & Conforms to API 22.2 Testing Protocol

Hemet, CA-January 31, 2007-Engineers with small line size processes looking for a precision flow meter will find the versatile Wafer-Cone® Flow Meter from McCrometer offers superior accuracy and is now approved by the Bureau of Land Management for use in coal-bed methane gas applications. In order to obtain the coal-bed methane gas approval, the BLM relied on the recent certification that McCrometer's Wafer-Cone Flow Meter conforms to the American Petroleum Institute's API 22.2 Testing Protocol for differential pressure flow meters.

The field-proven Wafer-Cone is an easy to install space-saving flow meter that requires almost no maintenance. Wafer-Cone's low maintenance combined with its long life results in lower total installation and life-cycle costs than many other flow meters.

The Wafer-Cone Flow Meter is designed for liquid or gas service in line sizes from 0.5 to 6 inches, which makes it ideal for either small process lines or many plant infrastructure tasks. Applications for the Wafer-Cone range from chemical injection or filtering in process lines to general plant needs, such as lines for natural gas, chilled water supporting burners or ovens, cooling systems, HVAC and more.

McCrometer's advanced Wafer-Cone Flow Meter relies on differential pressure sensing technology and sets the standard when it comes to performance, ease of use and economy. Its unique DP flow sensor is actually designed with built-in flow conditioning to achieve an accuracy of ±0.5%, with a repeatability of ±0.1%. It operates over a flow range of 10:1.

With the ability to self-condition flow, the Wafer-Cone Flow Meter is a real space-saver. It eliminates the need for extensive up/down stream straight pipe runs required by other DP technologies, such as orifice plates and venturi tubes. It can be installed virtually anywhere in a piping system or be easily retrofit into an existing piping layout, resulting in significant installation flexibility and initial cost savings.

Unlike traditional DP instruments such as orifice plates and venturi tubes, the Wafer-Cone Flow Meter's design is inherently more accurate because the flow conditioning function is built-into the basic flow sensor design. The Wafer-Cone conditions fluid flow to provide a stable flow profile that increases accuracy. The flow sensor's design features a centrally-located cone inside a tube. The cone interacts with the fluid flow and reshapes the velocity profile to create a lower pressure region immediately downstream.

The pressure difference, which is exhibited between the static line pressure and the low pressure created downstream of the cone, can be measured via two pressure sensing taps. One tap is placed slightly upstream of the cone and the other is located downstream of the cone. The pressure difference can then be incorporated into a derivation of the Bernoulli equation to determine the fluid flow rate.

The cone's central position in the line optimizes the velocity of the liquid flow at the point of measurement. It forms very short vortices as the flow passes the cone. These short vortices create a low amplitude, high frequency signal for excellent signal stability. The result is a highly stable flow profile that is repeatable for continuous accurate measurement. All of this is possible with a minimal straight pipe run of 0 to 3 diameters upstream and 0 to 1 diameters downstream from the flow meter.

About McCrometer

McCrometer's advanced liquid, steam and gas flow measurement solutions solve complex challenges in Municipal/Industrial Water & Wastewater, Oil & Gas, Process Control & Plant, Electric Power Generation, Institutional Facilities and Agriculture. The company's products and systems are found in thousands of installations worldwide. Its products and systems meet many of the world's most demanding industrial, safety and quality standards. Visit us on the web at www.mccrometer.com

Company Contact:
Gregg McCall, VP Marketing
Company Address:
3255 W Stetson Ave, Hemet, CA 92545
Product Brochure: http://www.mccrometer.com/library/pdf/24509-49.pdf
Web: http://www.mccrometer.com
Tel: 800-220-2279 Tel: 951-652-6811
Fax: 951-652-3078
Print Story
Print | 
Email |  Comment   Share  
Contacts: View detailed contact information.


User comments about this story

Annubar

Quotation one system velocity of air.
diameter of duct 24":
Price ???

By Jesus torres merino on Mar 10, 2010 19:53

Reply to this comment


 

Post a comment about this story

Name:
E-mail:
(your e-mail address will not be posted)
Comment title:
Comment:
To submit comment, enter the security code shown below and press 'Post Comment'.
 



 See related product stories
More .....
<!-- PNA - News | PNACON |  18860 -->
Don’t hunt for stories like this.
Let Product News Come to You!
Get a Free Subscription
to Product News Alerts.
Edit Story Categories
-- IMT - News | IMTREG2 |  18716 --
Start Your Free
Subscription to
Industry Market Trends.
 See more product news in:
Sensors, Monitors and Transducers
Test and Measuring Instruments
 More New Product News from this company:
Direct Mount Flowmeter features direct mount configuration.
Telemetry System supports irrigation applications.
Insertion Flow Meter provides bi-directional measurement.
Electromagnetic Flow Meter supports hot tap installation.
Inline Flow Meter targets water filtration plants.
More ....
 Other News from this company:
McCrometer's FPI Mag (Full Profile Insertion) and Ultra Mag Flow Meters Receive ISO Certification
FPI Mag(TM) (Full Profile Insertion) Flow Meter Delivers High Accuracy with New CSA Certification
McCrometer Exhibits Space-Saving V-Cone Flow Meter with Live Demo at OTC 2013
"Wafer-Cone Flow Meter Is Now Available With CE Marking for All Service Categories Under European Pressure Equipment Directive (PED)
McCrometer's V-Cone Flow Meter Obtains GOST-R Certification
More ....
 Tools for you
Watch Company 
View Company Profile
Company web site
More news from this company
E-Mail Story
Save Story
Search for suppliers of
Differential Pressure Flowmeters
Gas Flowmeters
Join the forum discussion at:
Tools of the Trade


Home  |  My ThomasNet News®  |  Industry Market Trends®  |  Submit Release  |  Advertise  |  Contact News  |  About Us
Brought to you by Thomasnet.com        Browse ThomasNet Directory

Copyright © 2013 Thomas Publishing Company. All Rights Reserved.
Terms of Use - Privacy Policy



Error close

Please enter a valid email address