August 1, 2008 - Featuring substitution and closed loop test methods, NSG 4070 meets automotive industry standards for bulk current injection test methods, including ISO 11452-4. With modular set-up that utilizes internal/external amplifiers, it is also useful in non-automotive test labs and design departments for RF conducted immunity testing according to IEC 61000-4-6. Front panel of system includes 5.7 in. TFT color display, push buttons, USB port, and external access to signal generator output.

(Archive News Story - Products mentioned in this Archive News Story may or may not be available from the manufacturer.)
Original Press release

Teseq, Inc.
52 Mayfield Ave.
Edison, NJ, 08837
USA



Teseq's NSG 4070 Test System Effectively Generates a Variety of Automotive and RF Immunity Test Methods


Edison, N.J. - Teseq Inc., a leading developer and provider of instrumentation and systems for EMC emission and immunity testing, has upgraded its multifunctional NSG 4070 EMC immunity test system to meet automotive industry standards for bulk current injection (BCI) test methods, including ISO 11452-4.

The system features substitution and closed loop test methods, making the system ideal for determining the immunity of electronic components used in many domestic and foreign passenger cars and commercial vehicles among leading automotive manufacturers including Ford, GM, Chrysler, Nissan, Renault and Peugeot. The NSG 4070 also includes an optional monitoring probe for recording the actual injected current or for when closed loop testing is required.

With a wide frequency range of 9 KHz to 1 GHz and a modular set-up that uses internal or external amplifiers, the NSG 4070 is also useful in non-automotive test labs and design departments for RF conducted immunity testing according to IEC 61000-4-6. Testing to other industry standards for radiated immunity, such as IEC 61000-4-3 and IEC 61000-4-20, is also possible with optional software.

The front panel of the NSG 4070 features a 5.7-inch TFT color display, push buttons for access to important functions, a 9 KHz to 1 GHz three-channel power meter and external access to signal generator output as well as power amplifier input and output. A convenient USB port enables the transfer of test and measurement data for documentation purposes.

A built-in report generator allows access to test results and easy-to-use firmware makes the system independent from external PC and control software. In addition, the NSG 4070 includes basic remote control software that enables remote testing via an RS232, LAN or USB port.

The system's back panel offers analog, digital and optical monitoring inputs for extensive equipment under test (EUT) monitoring options. A user port for four TTL inputs, four TTL outputs and supply voltages as well as EUT monitoring ports for analog, digital and optical inputs makes the NSG 4070 ideal for individual monitoring and control applications. The system includes a 10 MHz reference for synchronization and a trigger input for external control of measurement routines.

Pricing for the NSG 4070 Test System starts at $13,900. Lead-time is approximately 8 weeks ARO.

For more information, please visit www.teseq.com or contact MaryJane Salvador, Teseq Inc., 52 Mayfield Avenue, Edison, N.J. 08837. Tel: (732) 417-0501 ext. 239; Fax: (732) 417-0511; E-mail: maryjane.salvador@teseq.com. Web: www.teseq.com.

Teseq Inc. was formerly known as Schaffner Test Systems until a management buyout was finalized in November 2006. The company provides EMC instrumentation and systems for EMC emission and immunity testing in the automotive, consumer electronics, telecommunications, medical, aerospace and defense industries. It has approximately 130 employees and has been accredited to perform calibration services according to ISO 17025 at its Edison, N.J. laboratory. Teseq is the only pulsed immunity manufacturer in North America with an accredited calibration lab
Print | 
Email |  Comment   Share  
Contacts: View detailed contact information.


 

Post a comment about this story

Name:
E-mail:
(your e-mail address will not be posted)
Comment title:
Comment:
To submit comment, enter the security code shown below and press 'Post Comment'.
 



 See related product stories
More .....
 Newsletters
Industry Market Trends
Has Got It
  • Latest developments
  • Trends
  • Best practices
  • Opinions & Commentary
Get Ahead. Get IMT.
Subscribe Free Today
Subscribe   View Sample

Your Gateway to a Fast Changing World
Product News Alerts
Receive similar stories and other customized news to keep you in the know on the products shaping industry.
Subscribe Free Today
Subscribe   View Sample
 See more product news in:
Test and Measuring Instruments
Transportation Industry Products
 More New Product News from this company:
Dual Voltage Supply Source features self-regulation.
EMC Emission/Immunity Tester is offered with telecom surge module.
Digital EMI Receiver/Analyzer suits small- to mid-sized labs.
Coupling/Decoupling Network offers automated surge testing.
PPM Electric Field Probes suit EMC/EMI testing applications.
More ....
 Other News from this company:
Teseq Holding AG Acquires MILMEGA to Expand RF Power Amplifier Capabilities
Teseq Receives Expanded A2LA Certification to Perform Accredited Calibration to a Broader Range of Standards
More ....
 Tools for you
Watch Company 
View Company Profile
Company web site
More news from this company
E-Mail Story
Save Story
Search for suppliers of
Emissions Analyzers
Emissions Testers
Automotive Testers
EMC/RFI Testers
Test Systems
Join the forum discussion at:
Tools of the Trade


Home  |  My ThomasNet News®  |  Industry Market Trends  |  Submit Release  |  Advertise  |  Contact News  |  About Us
Brought to you by Thomasnet.com        Browse ThomasNet Directory

Copyright © 2012 Thomas Publishing Company
Terms of Use - Privacy Policy