Dissolved Oxygen Sensor withstands pressures up to 145 psi.

Print | 
Email |  Comment   Share  
Dissolved Oxygen Sensor withstands pressures up to 145 psi.
Dissolved Oxygen Sensor withstands pressures up to 145 psi.

Click Here to Enlarge Picture

November 25, 2008 - Featuring maximum error rate of less than 2%, Triton DO8 offers repeatability of ±0.5% and resolution of 0.01 ppm or 0.01% saturation. It provides 3 different outputs including 0-20 ppm, 0-200% saturation, or 0-500 psi, withstands ambient temperatures from 0-140°F, and records measurements at 20-120°F. Self-monitoring unit uses fluorescence quenching (FQ) optical technology coupled with microprocessor-based electronics, and stores calibration data within sensor.

(Archive News Story - Products mentioned in this Archive News Story may or may not be available from the manufacturer.)
Original Press release

Electro-Chemical Devices, Inc.
23665 Via Del Rio
Yorba Linda, CA, 92887
USA



New Triton DO8 Sensor with Optical FQ Technology Enhances Accuracy, Reduces Maintenance & Cuts Cost


Ideal For Drinking Water, Surface Water Monitoring, AquaCulture Municipal Wastewater Treatment, Industrial Water Treatment

Yorba Linda, CA-November 11, 2008-With a state-of-the-art fluorescence quenching (FQ) sensing element, the breakthrough Triton DO8 Dissolved Oxygen Sensor from Electro-Chemical Devices (ECD) delivers exceptionally accurate DO measurement with greatly reduced maintenance requirements for a low cost of ownership over a long service life in a wide range of municipal and industrial water treatment applications.

The trouble-free Triton DO8 Sensor is designed with precision FQ optical technology coupled with intelligent microprocessor-based electronics. The self-monitoring DO8 stores calibration data within the sensor, which minimizes maintenance over long service intervals while providing stable, dependable DO measurement.

The highly accurate Triton DO8 Sensor features a maximum error rate of less than 2 percent, repeatability of ±0.5 percent and resolution of 0.01 ppm or 0.01 percent saturation. It operates over a wide measurement range with three different outputs from 0 to 20 mg/l (0-20 ppm), 0-200 percent saturation or 0-500 hPa (0-6 psi).

Developed for rugged municipal and industrial water treatment environments, the tough Triton DO8 Sensor is designed to withstand ambient temperatures from -20 to 60°C (0-140°F) and records measurements at temperatures from -5 to 50°C (20-120°F). It withstands pressures up to a maximum of 10 bar (145 psi).

The Triton DO8 Sensor relies on a proven fluorescence quenching method to determine the oxygen concentration in water. A circular layer of optically-active, oxygen-sensitive molecules is integrated into an easily replaceable cap. This durable layer is highly permeable to oxygen and rapidly equilibrates to its surroundings. The cap aligns the optically-active fluorescence layer above two optical components inside the sensor-an emitter and a detector.

The sensor's emitter flashes a green light at the layer and the layer fluoresces back a red light. The duration and intensity of the fluorescence are directly dependent on the amount of oxygen in the layer. With little to no oxygen in the layer, the response is longer and more intense. The presence of more oxygen, however, quenches (reduces) the fluorescence effect.

The Triton DO8 Sensor continuously analyzes the oxygen level, water temperature and air pressure to calculate dissolved oxygen values. Via digital communications, the DO8 sends DO data to ECD's C-22 Controller, which provides a 4-20mA output signal to a water treatment plant's control room. The RS-485 digital signal is nearly immune to common EMI/RFI noise that is typically a problem in many plant environments.

Unlike amperometric sensors, the Triton DO8 has no membranes to replace, no electrolytes to refill and no anode/cathode assemblies to service or replace. The only service required is the simple replacement of the DO8's sensor cap, which lasts two years or longer, and the occasional wiping of the sensor head with a damp rag.

About Electro-Chemical Devices

Electro-Chemical Devices (ECD) is a manufacturer of liquid analytical process instrumentation. Founded in 1977, ECD has been in business for over 30 years and has built its industry leading reputation by its commitment to customers through this basic approach: Provide quality products, develop technical innovations and provide responsive, knowledgeable service.

Company Contact: Joe Bradley: 714-692-1333
Company Address: 23665
Via Del Rio,
Yorba Linda,
CA 92887
USA
Web: http://www.ecdi.com
Email: sales@ecdi.com
Tel: 800-729-1333
Tel: 714-692-1333
Fax: 714-692-1222
Print | 
Email |  Comment   Share  
Contacts: View detailed contact information.


 

Post a comment about this story

Name:
E-mail:
(your e-mail address will not be posted)
Comment title:
Comment:
To submit comment, enter the security code shown below and press 'Post Comment'.
 



 See related product stories
More .....
 Newsletters
Industry Market Trends
Has Got It
  • Latest developments
  • Trends
  • Best practices
  • Opinions & Commentary
Get Ahead. Get IMT.
Subscribe Free Today
Subscribe   View Sample

Your Gateway to a Fast Changing World
Product News Alerts
Receive similar stories and other customized news to keep you in the know on the products shaping industry.
Subscribe Free Today
Subscribe   View Sample
 See more product news in:
Sensors, Monitors and Transducers
 More New Product News from this company:
Ammonium Sensors suit water treatment applications.
Boiler Blowdown Controller reduces water and energy consumption.
Dechlorination Analyzer requires no chemicals to monitor seawater.
Air Blast Spray Cleaner cleans sensors in water treatment systems.
Conductivity Sensor withstands harsh industrial processes.
More ....
 Other News from this company:
Versatile Chlorine Sensors Simplify Water Monitoring
ECD 2010 CD Product Catalog Now Available
More ....
 Tools for you
Watch Company 
View Company Profile
Company web site
More news from this company
E-Mail Story
Save Story
Search for suppliers of
Optical Sensors
Dissolved Oxygen Sensors
Join the forum discussion at:
Tools of the Trade


Home  |  My ThomasNet News®  |  Industry Market Trends  |  Submit Release  |  Advertise  |  Contact News  |  About Us
Brought to you by Thomasnet.com        Browse ThomasNet Directory

Copyright © 2012 Thomas Publishing Company
Terms of Use - Privacy Policy