Current Transducers offer 0-5 Vdc or 4-20 mAdc output.

Print | 
Email |  Comment   Share  
Current Transducers offer 0-5 Vdc or 4-20 mAdc output.
Current Transducers offer 0-5 Vdc or 4-20 mAdc output.

Click Here to Enlarge Picture

May 23, 2005 - Split Core Transducers are available in 5 models including True RMS Model CR4100S, Loop powered Model CR4200S, Self-powered Model 4210S, Average RMS Model CR4400S, and DC current Model CR5200S. Powered by single 24 Vdc supply, units operate from 0–60°C with ±1.0% FS accuracy. Window openings accommodate current carrying wires up to 1.21 in. dia. Transducers include latch that secures split core armature, but can also be mounted on 35 mm DIN rails or surface/panels.

(Archive News Story - Products mentioned in this Archive News Story may or may not be available from the manufacturer.)
Original Press release

CR Magnetics
3500 Scarlet Oak Blvd.
St. Louis, MO, 63122
USA


New Split Core Transducers Introduced by CR Magnetics, Inc.

CR Magnetics, Inc. has introduced a new series of current transducers with split core current sensors specifically designed for easy installation into new and existing systems.

The new CR Magnetics Split Core Transducers are available in five different model styles: #CR4100S - True RMS, #CR4200S - Loop powered, #CR4210S - Self powered, #CR4400S - Average RMS, and #CR5200S - DC current. These models are available with 0-5 Vdc or 4-20m Adc output options.

Major benefits of the new Split Core Transducers allow easy assembly and greater manufacturing versatility in OEM equipment than solid core transducer designs. The new transducers are also perfect for retrofit applications as they can be installed without causing any equipment down time.

The key feature of the new CR Magnetics Split Core Transducers is the easy to use latch which secures the split core armature. They can also be mounted on 35 mm DIN rails or surface/panels.

The window openings of the new CR Magnetics CR4XXXS Series of Split Core Transducers will accommodate current carrying wires up to 1.21" dia. They operate in the temperature range of 0 - 60 degrees C and the accuracy is +/-1.0% Full Scale. Insulation voltage is 2500 Vdc and response time is 250ms 0-90% FS. They are powered by a single 24 Vdc power supply.

The common package size is 3.26" long x 1.42" wide x 2.99" high. And they are ... In Stock And Available For Immediate Shipment!

Upon introducing the new CR Magnetics Split Core Transducers, David P. Forsythe, General Manager of CR Magnetics, Inc., stated: "We are very excited about this new series of split core transducers. The new Split Core Transducers will perform in a wide variety of applications including phase fired control heaters, quickly varying motor leads, chopped wave form drivers, harmonic currents, and monitoring of motor faults, heater and lighting elements. We are counting on the use of our web site crmagnetics.com to help the design engineers and plant maintenance engineers with quick access to extensive technical information and specific application data."

Additional information regarding the new CR Magnetics Split Core Transducers may be obtained by contacting:

Mr. Tim Decker, Senior Product Manager

CR Magnetics, Inc.

3500 Scarlet Oak Blvd.

St. Louis, MO 63122 USA

Telephone: (636) 343-8518

FAX: (636) 343-5119

Email: timd@crmagnetics.com

Website: crmagnetics.com

Product feature information and technical data is available online at crmagnetics.com

CR Magnetics, Inc. is based in St. Louis. Missouri USA. The firm specializes in the design, marketing and manufacturing of voltage, current, power and frequency measurement products including Indicators, Sensing Transformers, Sensing Relays, Analog Transducers, Digital Displays, Digital Transducers and Software ...For markets in the United States and throughout the world. CR Magnetics is another Huntington Electric Company.
Print | 
Email |  Comment   Share  
Contacts: View detailed contact information.


 

Post a comment about this story

Name:
E-mail:
(your e-mail address will not be posted)
Comment title:
Comment:
To submit comment, enter the security code shown below and press 'Post Comment'.
 



 See related product stories
More .....
Don’t hunt for stories like this.
Let Product News Come to You!
Get a Free Subscription
to Product News Alerts.
Edit Story Categories
Start Your Free
Subscription to
Industry Market Trends.
 See more product news in:
Electrical Equipment and Systems
Sensors, Monitors and Transducers
 More New Product News from this company:
Current Transformers are designed for power monitoring.
Transducers measure -90 to +90 phase differences.
Digital Panel Meters offer variety of display options.
Digital Transducers have built-in energy totalizer.
More ....
 Tools for you
Watch Company 
View Company Profile
Company web site
More news from this company
E-Mail Story
Save Story
Search for suppliers of
Current, Voltage, Power Transducers
Join the forum discussion at:
Wired In


Home  |  My ThomasNet News®  |  Industry Market Trends  |  Submit Release  |  Advertise  |  Contact News  |  About Us
Brought to you by Thomasnet.com        Browse ThomasNet Directory

Copyright © 2012 Thomas Publishing Company
Terms of Use - Privacy Policy



Error close

Please enter a valid email address