ThomasNet Home   |   Promote Your Business
Home  |   My ThomasNet News®  |   Industry Market Trends  |   Submit Release  |   Advertise  |   About Us Feb 14, 2012  

Biocompatible Dielectric Material suits medical devices.

Print | 
Email |  Comment   Share  
Biocompatible Dielectric Material suits medical devices.
Biocompatible Dielectric Material suits medical devices.

Click Here to Enlarge Picture

June 10, 2003 - High strength toughened fluoropolymer (HSTF), produced through manipulation of PTFE microstructure, offers scrape abrasion resistance, cut-through resistance, and dielectric strength of 1.4 kV/mil in pinhole free profiles as thin as 0.0005 in. Material can be applied over conductors as small as 50 AWG wire. Applications include electrophysiology products and other catheter-based products where space is limited and reliability is crucial.

(Archive News Story - Products mentioned in this Archive News Story may or may not be available from the manufacturer.)
Original Press release

Gore, W. L., & Associates, Inc., Industrial Filtration Technologies
101 Lewisville Rd.
Elkton, MD, 21921
USA


Gore Offers Advanced Biocompatible Dielectric Material for Medical Devices

Elkton, Md. (June, 2003) W. L. Gore & Associates, Inc., a leading medical device and electronic components manufacturer, offers a high strength toughened fluoropolymer (HSTF) to the medical marketplace. This dielectric material is ideal for electrophysiology devices where reliability is critical and space is limited.

HSTF is an advanced biocompatible material produced by Gore scientists and engineers through manipulation of PTFE's microstructure. This process has led to a material with superior mechanical and electrical properties when compared to other fluoropolymers. This enhancement offers greater scrape abrasion resistance, cut-through resistance, high toughness for resisting dynamic loads, and high dielectric strength in ultra-thin, pinhole free profiles.

HSTF, as thin as 0.0005 in. (0.02 mm), can be applied over conductors as small as 50 AWG wire. This processing capability enables Gore to provide high performance wire and micro-cables to many demanding medical applications. The HSTF/conductor system dramatically increases strength and toughness through load sharing. The end benefits are added robustness and reliability for applications subject to high impulse forces, varying dynamics, or severe environments – typical in a variety of medical devices.

W. L. Gore & Associates, Inc. is a leader in providing high technology solutions for electronic, medical, industrial, and fabric applications. Headquartered in Newark, Delaware, Gore operates more than 45 facilities, has over a billion dollars in annual sales, and employs approximately 6,000 associates worldwide. Gore's manufacturing facilities are ISO 9001 certified and registered.

For more information, call W. L. Gore & Associates, Inc. at 800-445-4673 (USA), 302-292-5100 (international), or visit their Web site at www.gore.com/electronics.

Please send leads to:

Technical Marketing Support

W. L. Gore & Associates, Inc.

402 Vieve's Way

Elkton, MD 21922

(800) 445-4673
Print | 
Email |  Comment   Share  
Contacts: View detailed contact information.


 

Post a comment about this story

Name:
E-mail:
(your e-mail address will not be posted)
Comment title:
Comment:
To submit comment, enter the security code shown below and press 'Post Comment'.
 



 See related product stories
More .....
 Newsletters
Industry Market Trends
Has Got It
  • Latest developments
  • Trends
  • Best practices
  • Opinions & Commentary
Get Ahead. Get IMT.
Subscribe Free Today
Subscribe   View Sample

Your Gateway to a Fast Changing World
Product News Alerts
Receive similar stories and other customized news to keep you in the know on the products shaping industry.
Subscribe Free Today
Subscribe   View Sample
 See more product news in:
Paints and Coatings
 More New Product News from this company:
Gloves provide optimum grip, dexterity, and comfort.
Microminiature Round Cable suits medical applications.
Cable Assemblies are designed for motion environments.
DDR Cable Assemblies extend interconnect reach.
Thermal Interface Material features silicone-free design.
More ....
 Other News from this company:
Gore Announces Strategic Partnership with A. E. Petsche to Provide Firewire® Cable Products for the JSF Program
Gore's Fiber Optic Core Survives More Than 50 Million Rolling Flex Cycles
Gore Announces Exclusive North America Distributor of Wire and Cable
Gore Introduces New Online Configuration Tool for Specifying Microwave/RF Cable Assemblies
Gore Introduces New Online Configurator for Specifying Microwave/RF Cable Assemblies
More ....
 Tools for you
Watch Company 
View Company Profile
Company web site
More news from this company
E-Mail Story
Save Story
Search for suppliers of
Fluoropolymer Coatings
Join the forum discussion at:
Hard to Handle


Home  |  My ThomasNet News®  |  Industry Market Trends  |  Submit Release  |  Advertise  |  Contact News  |  About Us
Brought to you by Thomasnet.com        Browse ThomasNet Directory

Copyright © 2012 Thomas Publishing Company
Terms of Use - Privacy Policy