Air Blast Spray Cleaner cleans sensors in water treatment systems.

Print | 
Email |  Comment   Share  
Air Blast Spray Cleaner cleans sensors in water treatment systems.
Air Blast Spray Cleaner cleans sensors in water treatment systems.

Click Here to Enlarge Picture

February 10, 2011 - By preventing buildup of biofilms and other soft coatings, Model AC10 helps maintain accuracy of HYDRA Ammonium and Nitrate Analyzers in turbid water conditions. Automatic Sensor Cleaning System, combined with Sensor Spray Head and C22 Analyzer/Controller, uses pressurized air to generate area of high turbulence in water surrounding measurement end of sensor. Available with 115 Vac, 3.0 A or 220 Vac, 1.3 A air compressor, Model AC10 can be used as single- or dual-channel system.

(Archive News Story - Products mentioned in this Archive News Story may or may not be available from the manufacturer.)
Original Press release

Electro-Chemical Devices, Inc.
23665 Via Del Rio
Yorba Linda, CA, 92887
USA



AC10 Air Blast Spray Cleaner Reduces Maintenance and Improves Accuracy of HYDRA Analyzers


Monitoring For Municipal and Industrial Clean Water and Wastewater Treatment Systems

Irvine, CA - The new AC10 Air Blast Spray Cleaner from Electro-Chemical Devices (ECD) reduces manual sensor cleanings, helping to maintain the superior accuracy of the HYDRA Ammonium and Nitrate Analyzers while decreasing technician time and reducing plant operating costs for water and wastewater treatment.

The AC10 is an Automatic Sensor Cleaning System that decreases sensor maintenance cycles and helps maintain sensor measurement accuracy in turbid water conditions by preventing the buildup of biofilms and other soft coatings. The AC10 helps cut plant operating costs by reducing manual cleaning time and the amount of chemicals used for unnecessary water treatments performed due to inaccurate sensor readings caused by films and coatings that develop over time on the sensors.

The AC10 can be used as either a Single Channel or Dual Channel System with the HYDRA Ammonium and Nitrate sensors. Combined with a Sensor Spray Head and a C22 Analyzer/Controller, it uses pressurized air to generate an area of high turbulence in the water surrounding the measurement end of the sensor.

The AC10 Air Blast Spray Cleaner features a highly reliable high current contactor that assures years of trouble free service. It is available with either a 115 VAC 3.0 Amp or 220 VAC 1.3 Amp Air Compressor, housed in a rugged, corrosion resistant, fiberglass reinforced polyester enclosure. Installation options include wall mounting or an optional 2" handrail mounting system.

HYDRA Ammonium Sensor

The HYDRA Ammonium Analyzer features reliable ISE technology and a rugged PVC design, ideal for monitoring the nutrient load (NH4+) in the aeration basins of wastewater treatment plants. The HYDRA C22 analyzer automatically compensates for the pH dependent concentration equilibrium and potassium ion interference on the ammonium electrode.

HYDRA Nitrate Sensor

The HYDRA Nitrate Analyzer is designed to directly monitor the nitrification process in the aeration basins or clarifiers of wastewater treatment plants. Reliable ISE technology measures nitrate and chloride. The HYDRA C22 analyzer automatically compensates for chloride ion and temperature interference on the nitrate electrode. The HYDRA Nitrate Sensor is also available with an optional pH sensor.

In addition to the HYDRA Ammonium and Nitrate Analyzers, the AC10 Air Blast Spray Cleaner can be used with Triton® DO8 dissolved oxygen sensors or S10 style sensors for measuring pH, ORP, ISEs or conductivity.

About Electro-Chemical Devices

Electro-Chemical Devices (ECD) is a manufacturer of liquid analytical process instrumentation. Founded in 1977, ECD has been in business for over 30 years and has built its industry leading reputation by its commitment to customers through this basic approach: Provide quality products, develop technical innovations and provide responsive, knowledgeable service.

Company Contact: Joe Bradley: 949-336-6060

Company Address: 1681 Kettering, Irvine, CA 92614 USA

Web: http://www.ecdi.com Email: sales@ecdi.com

Tel: 800-729-1333 Tel: 949-336-6060 Fax: 949-336-6064
Print | 
Email |  Comment   Share  
Contacts: View detailed contact information.


 

Post a comment about this story

Name:
E-mail:
(your e-mail address will not be posted)
Comment title:
Comment:
To submit comment, enter the security code shown below and press 'Post Comment'.
 



 See related product stories
More .....
Don’t hunt for stories like this.
Let Product News Come to You!
Get a Free Subscription
to Product News Alerts.
Edit Story Categories
Start Your Free
Subscription to
Industry Market Trends.
 See more product news in:
Machinery and Machining Tools
Materials and Material Processing
 More New Product News from this company:
Ammonium Sensors suit water treatment applications.
Boiler Blowdown Controller reduces water and energy consumption.
Dechlorination Analyzer requires no chemicals to monitor seawater.
Conductivity Sensor withstands harsh industrial processes.
More ....
 Other News from this company:
Versatile Chlorine Sensors Simplify Water Monitoring
ECD 2010 CD Product Catalog Now Available
More ....
 Tools for you
Watch Company 
View Company Profile
Company web site
More news from this company
E-Mail Story
Save Story
Search for suppliers of
Air Blast Equipment
Air Blast Cleaning Machinery
Join the forum discussion at:
Tools of the Trade


Home  |  My ThomasNet News®  |  Industry Market Trends  |  Submit Release  |  Advertise  |  Contact News  |  About Us
Brought to you by Thomasnet.com        Browse ThomasNet Directory

Copyright © 2012 Thomas Publishing Company
Terms of Use - Privacy Policy



Error close

Please enter a valid email address