Quantcast
 
Search for: Search what?
Nov 9, 2009  
 Sections
Latest New Product News
Industry Market Trends
Green & Clean News
Association & Government News
Adhesives and Sealants
Agricultural and Farming Products
Architectural and Civil Engineering Products
Automatic ID
Chemical Processing and Waste Management
Cleaning Products and Equipment
Communication Systems and Equipment
Computer Hardware and Peripherals
Construction Equipment and Supplies
Controls and Controllers
Display and Presentation Equipment
Electrical Equipment and Systems
Electronic Components and Devices
Explosives, Armaments and Weaponry
Fasteners and Hardware
Fluid and Gas Flow Equipment
Food Processing and Preparation
Health, Medical and Dental Supplies and Equipment
HVAC
Labels, Tags, Signage and Equipment
Laboratory and Research Supplies and Equipment
Lubricants
Machinery and Machining Tools
Material Handling and Storage
Materials and Material Processing
Mechanical Components and Assemblies
Mechanical Power Transmission
Mining, Oil Drilling & Refining
Mounting and Attaching Products
Non-Industrial Products
Optics and Photonics
Packaging Products & Equipment
Paints and Coatings
Plant Furnishings and Accessories
Portable Tools
Printing and Duplicating Equipment
Retail and Sales Equipment
Robotics
Safety and Security Equipment
Sensors, Monitors and Transducers
Services
Software
Test and Measuring Instruments
Textile Industry Products
Thermal and Heating Equipment
Timers and Clocks
Transportation Industry Products
Vision Systems
Waste Handling Equipment
Welding Equipment and Supplies
 Press Releases
Products in the News
Company News
Mergers & Acquisitions
People in the News
Literature & Websites
 Resources
News Delivery Options
Browse Categories
Browse Companies
Mobile Edition
PR Resources
Licensing
Advertising
How to Write an effective Press Release
Trade Associations
Small Business Support
MEP
Advertisement
Instrument Data Recorder enables simultaneous sampling.
Instrument Data Recorder enables simultaneous sampling.

Click Here to Enlarge Picture

Instrument Data Recorder enables simultaneous sampling.


April 29, 2002 - DAQ 800 Series integrates field-connectable sensor termination, analog data acquisition, and sigma-delta analog-digital conversion (ADC). Available with 32 channel (DAQ832) or 48 channel (DAQ848) configurations, each channel offers independent 16-bit ADC resolution with programmable gain, and can sample rates at up to 200,000 samples/sec. They support aggregate data rates of up to 6.4 MB/sec, with no external signal conditioning required.

(Archive News Story - Products mentioned in this Archive News Story may or may not be available from the manufacturer.)

 See related product stories
Thermocouple Data Logger features integrated LCD display.
PCI Express Recorder targets high volume data streaming use.
Data Logging Sensor measures CO2, temperature, and humidity.
Portable Data Recorder includes real-time analysis software.
Temperature/Humidity Logger features USB connectivity.
 See more product news in:
Test and Measuring Instruments
 Tools for you
del.icio.us DIGG  
Facebook Reddit
StumbleUpon Twitter
Print This Page E-Mail Story
Watch_Company  Save Story
Contact company View Company Profile
Company web site 
More news from this company

Advertisement
More Tools and information
Search for suppliers of
Data Logging Recorders
Recorders
Data Acquisition Recorders
Join the forum discussion at:
 Tools of the Trade
 Newsletters
Your Gateway to a Fast Changing World
Product News Alerts
Receive similar stories and other customized news to keep you in the know on the products shaping industry.
Subscribe Free Today
Subscribe   View Sample

Industry Market Trends
Has Got It
  • Latest developments
  • Trends
  • Best practices
  • Opinions & Commentary
Get Ahead. Get IMT.
Subscribe Free Today
Subscribe   View Sample
 See more related product stories:
Machinery Data Logging System can store up to 32,767 events.
Portable Paperless Recorder has 200 MB internal memory.
Compact 2D Barcode Data Collector has 200 Kb of memory.
Current/Voltage Loggers store measurements on SD/MMC card.
Data Logger is built to withstand elevated temperatures.
Data Acquisition System offers operational flexibility.
RS-232 Data Logger captures serial data from devices.
Thermocouple Data Logger features built-in LCD.
Temperature Data Logger monitors in-transit items.
Portable Data Recorder aids maintenance/servicing tasks.
Data Logger facilitates environmental monitoring.
Data Logger records temperature, humidity, and dew point.
Process/Temperature Data Recorders measure 96 x 96 mm.
Pressure Data Logger has large, backlit LCD display.
Data Logger works with OS36 series infrared thermocouples.
Data Recording System delivers 800 MB/sec performance.
Humidity and Temperature Data Logger features LCD display.
Data Recorders feature 8-32 channels of 14 bit A/Ds.
Portable Signal Recorder/Player streams data at 500 MB/sec.
High-Speed Data Recorder works with 3.5 in. drives.

Compact, High-Capacity Digital Recorder from KineticSystems Delivers Complete Data Acquisition Solution

(Lockport, Illinois) - KineticSystems Co.'s new DAQ 800 Series integrates field-connectable sensor termination, analog data acquisition and high-performance sigma-delta analog-digital conversion (ADC) into a single high-speed, wide band instrumentation data recorder, available in either 32-channel (DAQ832) or 48-channel (DAQ848) configurations. Each channel features independent 16-bit ADC resolution with programmable gain, and is capable of sampling rates up to 200,000 samples/second. Data is transferred via a noise-resistant fiber optic cable to a host PC running KineticSystems' new easy-to-use DynaDAQ control software to form a complete PC-based data acquisition system. Both the DAQ832 and DAQ848 can support aggregate data rates of up to 6.4 MB/sec. No external signal conditioning is required. The DAQ832 system is listed at under $30,000, while the DAQ848 is priced at under $40,000.

"The DAQ832/848 is an ideal solid-state replacement for bulky analog tape recording devices," noted Steve Krebs, KineticSystems' Engineering Director, citing the typical digital-vs.-analog advantages of high dynamic range, random accessibility to data, high capacity, and high bandwidth. In addition, the media will not degrade over time, and data quality is not affected by duplication. The 15.1-inch high unit has a small footprint of just 21 ˝" X 6" and weighs just 25 pounds.

"The system also offers a dramatic improvement in performance, with greatly enhanced speed and accuracy," continued Krebs. "For example, compare the 200,000/second sampling rate to analog systems typically limited to 50 Ksample range."

The self-cooled DAQ832/848 is suitable for either rack-mounted or tabletop use. Typical applications include general-purpose laboratory recording of analog signals from sensors such as accelerometers and thermocouples. Featuring a ruggedized steel enclosure, the instrument is particularly suited to capturing Noise-Vibration-Harshness (NVH) measurements.

To enable simultaneous sampling, each channel features an independent ADC with associated signal conditioning. The ADCs utilize advanced, highly accurate sigma-delta conversion architecture, which provides inherent filtering and synchronous sampling without the need for costly sample/hold amplifiers or sophisticated analog anti-aliasing filters. Unlike competitive recorders whose multiplexing of inputs to a common ADC increases the likelihood of crosstalk, the independent sigma-delta ADCs reduce crosstalk effects to negligible levels.

The DAQ 832/848 also features independently programmable gain per channel. Users may select from 10 voltage input ranges from ± 10 millivolts to ± 10 volts (up to ± 15 volts as an option), enabling the same recorder to handle both high- and low-level signals and ensuring full utilization of the ADCs' dynamic range.

Connections for field wiring of sensors are screw-type terminations located on the front of the unit. BNC requirement can be handled with an optional termination panel. Connections for each channel consist of signal, return and shield terminations. Two ground terminations are also provided for external connection. Screw-type terminal blocks are removable for easy access to the connections. Trifilar wound transformers are optionally available for improved rejection of common-mode coupling, particularly important in applications where high-frequency common-mode voltages could produce offset errors when acquiring low-level signals (for example, with high-frequency stimulus devices as used in ATE). Common-mode rejection of 80db (DC to 50 kHz) is typical. Connection to the host PC for setup, control and data collection is accomplished via a two-cable fiber optic highway, which provides high immunity to noise. Fiber optic connectivity also allows the DAQ832/848 to be located remotely from the host computer - up to two kilometers away - ideal for hazardous applications, such as the testing of rocket engines. The DAQ832/848 package includes KineticSystems' new DynaDAQ control software with intuitive graphic user interface (GUI) screens. Built on the Windows® NT OS and residing on the host computer, DynaDAQ controls data acquisition setup and configuration, automatic end-to-end system calibration, monitoring and data storage. Users will appreciate the software's capability for remote control of data collection, monitoring of data points and ability to modify data collection parameters, including sample rate, number of active channels and gain per channel. The software formats and exports data to analysis programs, such as LabVIEW, MATLAB®, DADiSP(TM) and other programs accepting ASCII file imports. A viewer utility provides post-processing graphing or charting of acquisition results.

For detailed specifications and available options, contact: KineticSystems Co., LLC, 900 N. State Street, Lockport, Illinois 60441, Phone: 1-800-DATA-NOW (328-2669), Worldwide Phone: (815) 838-0005, USA Fax: (815) 838-4424, Int'l Fax: (815) 838-3195, E-mail: mkt-info@kscorp.com or visit their Web site: www.kscorp.com.

Contacts:

Sales:
Lou Kelm Sales Support Manager
USA
Phone: 815-838-0005, Ext. 2054
FAX: 815-838-4424
Send email  E-mail this person

Company Information:
Name: KineticSystems Co., LLC
Address: 900 N. State St.
City: Lockport
State: IL
ZIP: 60441-2200
Country: USA
Phone: 815-838-0005
FAX: 815-838-4424
http://www.kscorp.com


More New Product News from this company:
Signal Conditioning Module integrates ADCs.
PXI DAQ Modules are multi-functional.
Controller features Pentium® M-based embedded processor.
WiFi Testing Systems provide EVM measurement of -45 dB.
ADC Module features on-board signal conditioning.
Multi-channel Digitizers offer up to 8 channels.
Adapter Card permits use of VME modules in VXI mainframe.
Digital I/O Module offers up to 256 channels.
CompactPCI/PXI DAC offers 64 analog output channels.
Slot-0 Controller features Pentium 4 embedded processor.

Other News from this company:
KineticSystems Launches Powerful Soft Front Panel Application for PXI/CompactPCI Products
KineticSystems Appoints Computer Aided Solutions as North American Distributor for the DAQ family



Click here for copyright permissions!
Copyright 2009 Thomas Publishing Company


 

Post a comment about this story

Name:
E-mail:
(your e-mail address will not be posted)
Comment title:
Comment:
 

Category Advertisements




ThomasNet News Advertisers




Home  |  My ThomasNet News  |  Industry Market Trends  |  Submit Release  |  Advertise  |  Contact News  |  About Us
Brought to you by Thomasnet.com        Browse ThomasNet Directory

Copyright © 2009 Thomas Publishing Company
Terms of Use - Privacy Policy