Quantcast
 
Search for: Search what?
Nov 23, 2009  
 Sections
Latest New Product News
Industry Market Trends
Green & Clean News
Association & Government News
Adhesives and Sealants
Agricultural and Farming Products
Architectural and Civil Engineering Products
Automatic ID
Chemical Processing and Waste Management
Cleaning Products and Equipment
Communication Systems and Equipment
Computer Hardware and Peripherals
Construction Equipment and Supplies
Controls and Controllers
Display and Presentation Equipment
Electrical Equipment and Systems
Electronic Components and Devices
Explosives, Armaments and Weaponry
Fasteners and Hardware
Fluid and Gas Flow Equipment
Food Processing and Preparation
Health, Medical and Dental Supplies and Equipment
HVAC
Labels, Tags, Signage and Equipment
Laboratory and Research Supplies and Equipment
Lubricants
Machinery and Machining Tools
Material Handling and Storage
Materials and Material Processing
Mechanical Components and Assemblies
Mechanical Power Transmission
Mining, Oil Drilling & Refining
Mounting and Attaching Products
Non-Industrial Products
Optics and Photonics
Packaging Products & Equipment
Paints and Coatings
Plant Furnishings and Accessories
Portable Tools
Printing and Duplicating Equipment
Retail and Sales Equipment
Robotics
Safety and Security Equipment
Sensors, Monitors and Transducers
Services
Software
Test and Measuring Instruments
Textile Industry Products
Thermal and Heating Equipment
Timers and Clocks
Transportation Industry Products
Vision Systems
Waste Handling Equipment
Welding Equipment and Supplies
 Press Releases
Products in the News
Company News
Mergers & Acquisitions
People in the News
Literature & Websites
 Resources
News Delivery Options
Browse Categories
Browse Companies
Mobile Edition
PR Resources
Licensing
Advertising
How to Write an effective Press Release
Trade Associations
Small Business Support
MEP
Advertisement
Flow Sensor has measuring range of 0-50 m/s.
Flow Sensor has measuring range of 0-50 m/s.

Click Here to Enlarge Picture

Flow Sensor has measuring range of 0-50 m/s.


February 19, 2009 - Model SS 20.260 immersion sensor with integrated transducer measures free and guided air in ducts from 1-40 in. long at temperatures up to 120°C. It operates from 24 Vdc supply, consumes 30 mA, and provides 4-20 mA linear output. Two status LEDs indicate correct operation or indicate wrong supply voltage or sensor defects. Sensor can be used to measure flow of air, nitrogen, argon, and non-burnable gases.

 See related product stories
Inductive Sensors can operate in environments up to 230°C.
Sensors are designed for measurement of internal ballistics.
Pressure Sensors suit field blast and shock tube application.
Inductive Proximity Sensor suits food and beverage industries.
Air Flow Measuring Probes are suited for duct applications.
 See more product news in:
HVAC
Sensors, Monitors and Transducers
Test and Measuring Instruments
 Tools for you
del.icio.us DIGG  
Facebook Reddit
StumbleUpon Twitter
Print This Page E-Mail Story
Watch_Company  Save Story
Contact company
Company web site 
More news from this company

Advertisement
More Tools and information
Search for suppliers of
Air Flow Sensors
Gas Flow Sensors
High Temperature Sensors
Join the forum discussion at:
 Tools of the Trade
 Newsletters
Your Gateway to a Fast Changing World
Product News Alerts
Receive similar stories and other customized news to keep you in the know on the products shaping industry.
Subscribe Free Today
Subscribe   View Sample

Industry Market Trends
Has Got It
  • Latest developments
  • Trends
  • Best practices
  • Opinions & Commentary
Get Ahead. Get IMT.
Subscribe Free Today
Subscribe   View Sample
 See more related product stories:
Temperature Probe measures diesel/bio-fuel exhaust.
Pressure Sensors suit furnace modulation applications.
Fiber Optic Temperature Sensor measures up to 1,000°C.
Air Flow Sensor comes with integrated dual color display.
Pressure/Temperature Sensor is used with R744 refrigerant.
Flow Sensor handles temperatures up to 350°C.
Metal Sensor is offered in IP 69k rated washdown version.
Thermal Flow Sensor can withstand explosive environment.
MEMS Flow Sensor suits HVAC air handling equipment.
Inductive Proximity Sensors withstand temperatures to 248°F.
Inductive Proximity Sensors operate up to 482°F.
Air and Gas Flow Sensor has 200 m/s measuring range.
Monitors provide in-flight systems analysis.
pH Sensors perform in temperatures to 293°F.
Inductive Sensors operate in environments up to 230°C.
Candlestick Sensor measures temperature and air velocity.
Air Flow Monitors are suited for dirty air streams.
Compressed Air Sensor monitors air consumption.
Airflow Sensor provides digital TTL output.
Air Flow Sensor provides pressure mapping.


SCHMIDT® Flow-Sensor SS 20.260 for Process Technology


For the employment in process technology the latest SCHMIDT® flow sensor SS 20.260 offers three crucial upgrades compared to his forerunner. With an expanded measuring range of 0 ... 50 m/s the sensor can be applied for flow rate control in a wide range of systems. Many processes require the measurement of heated gases and therefore an enhanced operating temperature. Depending on the configuration of the SS 20.260 it is up to 120 °C. The temperature can be measured with an additional linear output and no separate sensor is required any more. The unit is robust due to a chamber in which the sensing element is protected against impacts. The stainless steel sensor tube is available in different length and thus can be placed at the correct position regardless of the size of the duct. Two LED's indicate the correct operation or inform about wrong supply voltage or sensor defects. Applications: Flow measuring in air ducts, volume flow measuring in test benches, control of combustion air of oil, wood, gas or coal burners, flow control in cooling or drying constructions.

Main technical data:

Immersion sensor with integrated transducer.

Use of sensor: Free air and guided air in ducts from 25 to 1.000 mm (1 to 40 inch).

Medium: Air, Nitrogen, Argon and other non-burnable gases.

Measuring ranges:0 ... 2.5/10/20/40/50 m/s.

Pressure: Atmospheric.

Power supply: 24 VDC / power consumption only 30 mA.

Output: 0 ... 10 V / (0)4 ... 20 mA linear.

Functional display: 2 Status LED's

SCHMIDT Technology GmbH,

Feldbergstr. 1, 78112 St.

Georgen,

Phone.: +49/7724/899-0,

Fax:+49/7724/899101,

Email: sensors@schmidttechnology.de,

Homepage: www.schmidttechnology.de




Contacts:

Sales:
Mathias Moser Sales Group Manager, Division Sensors
USA
Phone: 0049 7724 899 179
Send email  E-mail this person

Company Information:
Name: SCHMIDT Technology GmbH
Address: Feldbergstraße 1
City: St. Georgen
ZIP: D-78112
Country: Germany
Phone: 0 77 24 / 8 99-0
FAX: 0 77 24 / 8 99-101
http://www.schmidttechnology.de


More New Product News from this company:
Flow Sensor handles temperatures up to 350°C.
Thermal Flow Sensor can withstand explosive environment.
Flow Sensor monitors laminar flow in cleanrooms.
Air and Gas Flow Sensor has 200 m/s measuring range.
Air/Gas Flow Sensor features integrated Fieldbus interface.
Flow Sensor detects flow direction.


Click here for copyright permissions!
Copyright 2009 Thomas Publishing Company


 

Post a comment about this story

Name:
E-mail:
(your e-mail address will not be posted)
Comment title:
Comment:
 

Category Advertisements
Farr Air Pollution Control HemiPleat Filter



Home  |  My ThomasNet News  |  Industry Market Trends  |  Submit Release  |  Advertise  |  Contact News  |  About Us
Brought to you by Thomasnet.com        Browse ThomasNet Directory

Copyright © 2009 Thomas Publishing Company
Terms of Use - Privacy Policy