Quantcast
 
Search for: Search what?
Nov 9, 2009  
 Sections
Latest New Product News
Industry Market Trends
Green & Clean News
Association & Government News
Adhesives and Sealants
Agricultural and Farming Products
Architectural and Civil Engineering Products
Automatic ID
Chemical Processing and Waste Management
Cleaning Products and Equipment
Communication Systems and Equipment
Computer Hardware and Peripherals
Construction Equipment and Supplies
Controls and Controllers
Display and Presentation Equipment
Electrical Equipment and Systems
Electronic Components and Devices
Explosives, Armaments and Weaponry
Fasteners and Hardware
Fluid and Gas Flow Equipment
Food Processing and Preparation
Health, Medical and Dental Supplies and Equipment
HVAC
Labels, Tags, Signage and Equipment
Laboratory and Research Supplies and Equipment
Lubricants
Machinery and Machining Tools
Material Handling and Storage
Materials and Material Processing
Mechanical Components and Assemblies
Mechanical Power Transmission
Mining, Oil Drilling & Refining
Mounting and Attaching Products
Non-Industrial Products
Optics and Photonics
Packaging Products & Equipment
Paints and Coatings
Plant Furnishings and Accessories
Portable Tools
Printing and Duplicating Equipment
Retail and Sales Equipment
Robotics
Safety and Security Equipment
Sensors, Monitors and Transducers
Services
Software
Test and Measuring Instruments
Textile Industry Products
Thermal and Heating Equipment
Timers and Clocks
Transportation Industry Products
Vision Systems
Waste Handling Equipment
Welding Equipment and Supplies
 Press Releases
Products in the News
Company News
Mergers & Acquisitions
People in the News
Literature & Websites
 Resources
News Delivery Options
Browse Categories
Browse Companies
Mobile Edition
PR Resources
Licensing
Advertising
How to Write an effective Press Release
Trade Associations
Small Business Support
MEP
Advertisement
Dissolved Oxygen Sensor withstands pressures up to 145 psi.
Dissolved Oxygen Sensor withstands pressures up to 145 psi.

Click Here to Enlarge Picture

Dissolved Oxygen Sensor withstands pressures up to 145 psi.


November 25, 2008 - Featuring maximum error rate of less than 2%, Triton DO8 offers repeatability of ±0.5% and resolution of 0.01 ppm or 0.01% saturation. It provides 3 different outputs including 0-20 ppm, 0-200% saturation, or 0-500 psi, withstands ambient temperatures from 0-140°F, and records measurements at 20-120°F. Self-monitoring unit uses fluorescence quenching (FQ) optical technology coupled with microprocessor-based electronics, and stores calibration data within sensor.

 See related product stories
Optical Sensor reacts to fluid spills as small as 1 mL.
Optical Sensor IC supports touchless motion detection.
Fiber Orientation-Angle Sensor targets paper/board makers.
Vision Sensors identify various codes, printed characters.
Optical Fork and Angle Sensors offer one-piece fixed-distance design.
 See more product news in:
Sensors, Monitors and Transducers
 Tools for you
del.icio.us DIGG  
Facebook Reddit
StumbleUpon Twitter
Print This Page E-Mail Story
Watch_Company  Save Story
Contact company View Company Profile
Company web site 
More news from this company

Advertisement
More Tools and information
Search for suppliers of
Optical Sensors
Dissolved Oxygen Sensors
Join the forum discussion at:
 Tools of the Trade
 Newsletters
Your Gateway to a Fast Changing World
Product News Alerts
Receive similar stories and other customized news to keep you in the know on the products shaping industry.
Subscribe Free Today
Subscribe   View Sample

Industry Market Trends
Has Got It
  • Latest developments
  • Trends
  • Best practices
  • Opinions & Commentary
Get Ahead. Get IMT.
Subscribe Free Today
Subscribe   View Sample
 See more related product stories:
Oxygen Sensor helps minimize beer losses in filling plants.
Proximity Sensor suits mobile electronics applications.
Photoelectric Level Sensors mount directly to standpipes.
Optical Displacement Sensors optimize quality control.
Sensors offer non-contact evaluation of welding cap quality.
Optical Sensors measure DO for bioprocess applications.
Optical Sensor measures dissolved oxygen during fermentation.
Dissolved Oxygen Monitor features auto-cleaning system.
Image Sensor is designed for use in medical endoscopes.
Dissolved Oxygen Sensor is suited for wastewater monitoring.
Optical Sensors feature ac or dc voltage operation.
Ultrasonic Sensor detects optically difficult targets.
Optical Displacement Sensor supports QC applications.
Fluorometer offers in situ characterization of water samples.
Photoelectric Sensor comes in compact metal housing.
Handheld Device provides full spectral analysis of light.
IR Temperature Sensors have dual output capability.
Optical Sensor IC is resistant to dirt build-up.
Optical Sensors feature cold storage exposure rating.
Optical Fork Sensors are used for label detection.


New Triton DO8 Sensor with Optical FQ Technology Enhances Accuracy, Reduces Maintenance & Cuts Cost


Ideal For Drinking Water, Surface Water Monitoring, AquaCulture Municipal Wastewater Treatment, Industrial Water Treatment

Yorba Linda, CA-November 11, 2008-With a state-of-the-art fluorescence quenching (FQ) sensing element, the breakthrough Triton DO8 Dissolved Oxygen Sensor from Electro-Chemical Devices (ECD) delivers exceptionally accurate DO measurement with greatly reduced maintenance requirements for a low cost of ownership over a long service life in a wide range of municipal and industrial water treatment applications.

The trouble-free Triton DO8 Sensor is designed with precision FQ optical technology coupled with intelligent microprocessor-based electronics. The self-monitoring DO8 stores calibration data within the sensor, which minimizes maintenance over long service intervals while providing stable, dependable DO measurement.

The highly accurate Triton DO8 Sensor features a maximum error rate of less than 2 percent, repeatability of ±0.5 percent and resolution of 0.01 ppm or 0.01 percent saturation. It operates over a wide measurement range with three different outputs from 0 to 20 mg/l (0-20 ppm), 0-200 percent saturation or 0-500 hPa (0-6 psi).

Developed for rugged municipal and industrial water treatment environments, the tough Triton DO8 Sensor is designed to withstand ambient temperatures from -20 to 60°C (0-140°F) and records measurements at temperatures from -5 to 50°C (20-120°F). It withstands pressures up to a maximum of 10 bar (145 psi).

The Triton DO8 Sensor relies on a proven fluorescence quenching method to determine the oxygen concentration in water. A circular layer of optically-active, oxygen-sensitive molecules is integrated into an easily replaceable cap. This durable layer is highly permeable to oxygen and rapidly equilibrates to its surroundings. The cap aligns the optically-active fluorescence layer above two optical components inside the sensor-an emitter and a detector.

The sensor's emitter flashes a green light at the layer and the layer fluoresces back a red light. The duration and intensity of the fluorescence are directly dependent on the amount of oxygen in the layer. With little to no oxygen in the layer, the response is longer and more intense. The presence of more oxygen, however, quenches (reduces) the fluorescence effect.

The Triton DO8 Sensor continuously analyzes the oxygen level, water temperature and air pressure to calculate dissolved oxygen values. Via digital communications, the DO8 sends DO data to ECD's C-22 Controller, which provides a 4-20mA output signal to a water treatment plant's control room. The RS-485 digital signal is nearly immune to common EMI/RFI noise that is typically a problem in many plant environments.

Unlike amperometric sensors, the Triton DO8 has no membranes to replace, no electrolytes to refill and no anode/cathode assemblies to service or replace. The only service required is the simple replacement of the DO8's sensor cap, which lasts two years or longer, and the occasional wiping of the sensor head with a damp rag.

About Electro-Chemical Devices

Electro-Chemical Devices (ECD) is a manufacturer of liquid analytical process instrumentation. Founded in 1977, ECD has been in business for over 30 years and has built its industry leading reputation by its commitment to customers through this basic approach: Provide quality products, develop technical innovations and provide responsive, knowledgeable service.

Company Contact: Joe Bradley: 714-692-1333
Company Address: 23665
Via Del Rio,
Yorba Linda,
CA 92887
USA
Web: http://www.ecdi.com
Email: sales@ecdi.com
Tel: 800-729-1333
Tel: 714-692-1333
Fax: 714-692-1222


Contacts:

Sales:
Joe Bradley
USA
Phone: 800-729-1333
FAX: 714-692-1222
Send email  E-mail this person

Public Relations:
Randy Brown
USA
Phone: 909-335-1941
Send email  E-mail this person

Company Information:
Name: Electro-Chemical Devices, Inc.
Address: 23665 Via Del Rio
City: Yorba Linda
State: CA
ZIP: 92887
Country: USA
Phone: 714-692-1333
FAX: 714-692-1222
http://www.ecdi.com


More New Product News from this company:
Analytical Sensors precisely determine Ammonium levels.
Cooling Tower Control eliminates excess chemical feeds.
Turbidity Analyzer utilizes multi-beam sensing technology.
Chlorine Analyzer eliminates pH sampling systems, reagents.
Automated Blowdown System increases boiler efficiency.
Chlorine Analyzer has pre-wired, panel mount design.


Click here for copyright permissions!
Copyright 2009 Thomas Publishing Company


 

Post a comment about this story

Name:
E-mail:
(your e-mail address will not be posted)
Comment title:
Comment:
 

ThomasNet News Advertisers





Home  |  My ThomasNet News  |  Industry Market Trends  |  Submit Release  |  Advertise  |  Contact News  |  About Us
Brought to you by Thomasnet.com        Browse ThomasNet Directory

Copyright © 2009 Thomas Publishing Company
Terms of Use - Privacy Policy