Quantcast
 
Search for: Search what?
Nov 25, 2009  
 Sections
Latest New Product News
Industry Market Trends
Green & Clean News
Association & Government News
Adhesives and Sealants
Agricultural and Farming Products
Architectural and Civil Engineering Products
Automatic ID
Chemical Processing and Waste Management
Cleaning Products and Equipment
Communication Systems and Equipment
Computer Hardware and Peripherals
Construction Equipment and Supplies
Controls and Controllers
Display and Presentation Equipment
Electrical Equipment and Systems
Electronic Components and Devices
Explosives, Armaments and Weaponry
Fasteners and Hardware
Fluid and Gas Flow Equipment
Food Processing and Preparation
Health, Medical and Dental Supplies and Equipment
HVAC
Labels, Tags, Signage and Equipment
Laboratory and Research Supplies and Equipment
Lubricants
Machinery and Machining Tools
Material Handling and Storage
Materials and Material Processing
Mechanical Components and Assemblies
Mechanical Power Transmission
Mining, Oil Drilling & Refining
Mounting and Attaching Products
Non-Industrial Products
Optics and Photonics
Packaging Products & Equipment
Paints and Coatings
Plant Furnishings and Accessories
Portable Tools
Printing and Duplicating Equipment
Retail and Sales Equipment
Robotics
Safety and Security Equipment
Sensors, Monitors and Transducers
Services
Software
Test and Measuring Instruments
Textile Industry Products
Thermal and Heating Equipment
Timers and Clocks
Transportation Industry Products
Vision Systems
Waste Handling Equipment
Welding Equipment and Supplies
 Press Releases
Products in the News
Company News
Mergers & Acquisitions
People in the News
Literature & Websites
 Resources
News Delivery Options
Browse Categories
Browse Companies
Mobile Edition
PR Resources
Licensing
Advertising
How to Write an effective Press Release
Trade Associations
Small Business Support
MEP
Advertisement
Chlorine Analyzer has pre-wired, panel mount design.
Chlorine Analyzer has pre-wired, panel mount design.

Click Here to Enlarge Picture

Chlorine Analyzer has pre-wired, panel mount design.


August 1, 2008 - FCA-22 Analyzer System monitors free chlorine in drinking water, rinse water, cooling water, and other fresh water samples from 0.05-20.0 ppm Cl2, 5-9 pH, and at temperatures from 32- 122°F. Constant head flow control device maintains optimum water flow past sensor over 10-80 gph incoming flows. Incorporated pH sensor provides compensation for samples from 6.5-9 pH, and Cl2 sensor's polarographic, gold/silver PFTE membrane construction extends sensor life.

(Archive News Story - Products mentioned in this Archive News Story may or may not be available from the manufacturer.)

 See related product stories
Chlorine Analyzer eliminates pH sampling systems, reagents.
Meter measures chlorine in liquids, semi-solids, and solids.
Total NSX Analyzer has compact, modular design.
Salt Analyzer measures chloride ions in samples.
At-Line Automation Analyzer targets food process industry.
 See more product news in:
Test and Measuring Instruments
 Tools for you
del.icio.us DIGG  
Facebook Reddit
StumbleUpon Twitter
Print This Page E-Mail Story
Watch_Company  Save Story
Contact company View Company Profile
Company web site 
More news from this company

Advertisement
More Tools and information
Search for suppliers of
Chlorine Analyzers
Join the forum discussion at:
 Tools of the Trade
 Newsletters
Your Gateway to a Fast Changing World
Product News Alerts
Receive similar stories and other customized news to keep you in the know on the products shaping industry.
Subscribe Free Today
Subscribe   View Sample

Industry Market Trends
Has Got It
  • Latest developments
  • Trends
  • Best practices
  • Opinions & Commentary
Get Ahead. Get IMT.
Subscribe Free Today
Subscribe   View Sample
 See more related product stories:
Intelligent Analyzer accommodates single-/dual-sensor input.
Turbidity Analyzer is suited for potable water plants.
Analysis System provides continuous chlorine measurement.


Free Chlorine Measurement as Simple as 1-2-3 with New FCA-22 Analyzer System


Ideal For Municipal Water Systems, Process Rinse Water for Food/Beverage Plants, Pulp/Paper Bleaching, Oxidation Control in Chemical Processing and Mining, Cooling Towers for Electric Power Plants or Oil/Gas Refineries

Yorba Linda, CA-July 16, 2008-The measurement and control of Free Chlorine has never been easier than with the new FCA-22 Analyzer System from Electro-Chemical Devices, Inc., which features a virtually plumb-and-play design. The panel mount design of this analyzer system comes factory pre-wired and with assembled flow tubing. ECD's advanced sensor and controller technologies allow installation and commissioning to be completed in just three easy steps utilizing simple tools.

Municipal water system and industrial process engineers will find the new advanced FCA-22 Analyzer precisely measures free residual chlorine while also offering a low cost-of-ownership. It features a long-lasting sensor that minimizes part replacement and technician labor expenses.

The FCA-22 Analyzer provides highly reliable on-line continuous free chlorine measurement in a complete systems package. It is designed to monitor free chlorine in drinking water, rinse water, cooling water and other fresh water samples from 0.05 to 20.0 ppm Cl2, 5 to 9 pH and at temperatures from 32 to 122°F (0 to 50°C).

The design criteria for ECD's new sophisticated chlorine sensor were high accuracy with a minimal maintenance requirement. Constant head flow control, automatic pH compensation and a rugged amperometric Cl2 sensor keep maintenance to a minimum with unsurpassed accuracy and performance.

The FCA-22's constant head flow control device (CFD) maintains the optimum water flow past the sensor over a wide range of incoming sample flow rates from 10 to 80 gallons per hour. The incorporation of a pH sensor in the FCA-22 provides accurate compensation for samples from 6.5 to 9 pH, which eliminates the need for an expensive pH sample conditioning system. The Cl2 sensor's polarographic, gold/silver PFTE membrane construction extends sensor life to reduce operational costs.

With many other free Chlorine sensor technologies, electrolyte replacement is a monthly or bimonthly task that requires the constant purchase of refill kits. A technician is required to refurbish and re-install the sensor and reconfirm the calibration, which results in unnecessary parts and labor expense that adds up over the complete life of the analyzer. The new FCA-22's advanced design extends sensor life to approximately one year.

The FCA-22's multi-bus controller design enables easy customization of various outputs and control functions. The standard FCA-22 has two SPDT relays and a 4 to 20 mA output for the free chlorine signal, with additional outputs available as an option.

About Electro-Chemical Devices

Electro-Chemical Devices (ECD) is a manufacturer of liquid analytical process instrumentation. Founded in 1977, ECD has been in business for over 30 years and has built its industry leading reputation by its commitment to customers through this basic approach: Provide quality products, develop technical innovations and provide responsive, knowledgeable service.

Brochure: http://www.ecdi.com/downloads/literat...


Contacts:

Public Relations:
RB Marketing Communications
Randy Brown
700 E Redlands Blvd. St. U-347
Redlands CA 92373
USA
Phone: 909-335-1941
Send email  E-mail this person

General Information:
Joe Bradley
USA
Phone: 714-692-1333

Company Information:
Name: Electro-Chemical Devices, Inc.
Address: 23665 Via Del Rio
City: Yorba Linda
State: CA
ZIP: 92887
Country: USA
Phone: 714-692-1333
FAX: 714-692-1222
http://www.ecdi.com


More New Product News from this company:
Ammonium Analyzer requires virtually no maintenance.
Sensors analyze sulfates and H2S in water plants.
Analytical Sensors precisely determine Ammonium levels.
Cooling Tower Control eliminates excess chemical feeds.
Turbidity Analyzer utilizes multi-beam sensing technology.
Chlorine Analyzer eliminates pH sampling systems, reagents.
Automated Blowdown System increases boiler efficiency.
Dissolved Oxygen Sensor withstands pressures up to 145 psi.


Click here for copyright permissions!
Copyright 2009 Thomas Publishing Company


 

Post a comment about this story

Name:
E-mail:
(your e-mail address will not be posted)
Comment title:
Comment:
 

Category Advertisements




ThomasNet News Advertisers



TIMING BELTS & PULLEYS


Home  |  My ThomasNet News  |  Industry Market Trends  |  Submit Release  |  Advertise  |  Contact News  |  About Us
Brought to you by Thomasnet.com        Browse ThomasNet Directory

Copyright © 2009 Thomas Publishing Company
Terms of Use - Privacy Policy