Quantcast
 
Search for: Search what?
Nov 24, 2009  
 Sections
Latest New Product News
Industry Market Trends
Green & Clean News
Association & Government News
Adhesives and Sealants
Agricultural and Farming Products
Architectural and Civil Engineering Products
Automatic ID
Chemical Processing and Waste Management
Cleaning Products and Equipment
Communication Systems and Equipment
Computer Hardware and Peripherals
Construction Equipment and Supplies
Controls and Controllers
Display and Presentation Equipment
Electrical Equipment and Systems
Electronic Components and Devices
Explosives, Armaments and Weaponry
Fasteners and Hardware
Fluid and Gas Flow Equipment
Food Processing and Preparation
Health, Medical and Dental Supplies and Equipment
HVAC
Labels, Tags, Signage and Equipment
Laboratory and Research Supplies and Equipment
Lubricants
Machinery and Machining Tools
Material Handling and Storage
Materials and Material Processing
Mechanical Components and Assemblies
Mechanical Power Transmission
Mining, Oil Drilling & Refining
Mounting and Attaching Products
Non-Industrial Products
Optics and Photonics
Packaging Products & Equipment
Paints and Coatings
Plant Furnishings and Accessories
Portable Tools
Printing and Duplicating Equipment
Retail and Sales Equipment
Robotics
Safety and Security Equipment
Sensors, Monitors and Transducers
Services
Software
Test and Measuring Instruments
Textile Industry Products
Thermal and Heating Equipment
Timers and Clocks
Transportation Industry Products
Vision Systems
Waste Handling Equipment
Welding Equipment and Supplies
 Press Releases
Products in the News
Company News
Mergers & Acquisitions
People in the News
Literature & Websites
 Resources
News Delivery Options
Browse Categories
Browse Companies
Mobile Edition
PR Resources
Licensing
Advertising
How to Write an effective Press Release
Trade Associations
Small Business Support
MEP
Advertisement
Dissolved Oxygen Meter uses polarigraphic type probe.
Dissolved Oxygen Meter uses polarigraphic type probe.

Click Here to Enlarge Picture

Dissolved Oxygen Meter uses polarigraphic type probe.


February 12, 2002 - LCD digital meter is designed to measure dissolved oxygen in field or laboratory with DO accuracy of ±1.5% full scale and temperature accuracy of ±1% full scale. O2 measurement range is 0.00 to 19.00 PPM, and temperature range is 0.0° to 50.0°C. Both are displayed on 3.5 digit LCD readout with 1/2 in. high numerals. Meter includes automatic temperature compensation over range of 0° to 30°C. It uses 9V battery for 100 hrs continuous service.

(Archive News Story - Products mentioned in this Archive News Story may or may not be available from the manufacturer.)

 See related product stories
Portable Dissolved Oxygen Meter is microprocessor-based.
Dissolved Oxygen System features single-use design.
Dissolved Oxygen Meter is self-cleaning and self-calibrating.
Probe provides BOD analysis.
Dissolved Oxygen Meter features self-stirring probe.
 See more product news in:
Test and Measuring Instruments
 Tools for you
del.icio.us DIGG  
Facebook Reddit
StumbleUpon Twitter
Print This Page E-Mail Story
Watch_Company  Save Story
Contact company View Company Profile
Company web site 
More news from this company

Advertisement
More Tools and information
Search for suppliers of
Dissolved Oxygen Meters
Join the forum discussion at:
 Tools of the Trade
 Newsletters
Your Gateway to a Fast Changing World
Product News Alerts
Receive similar stories and other customized news to keep you in the know on the products shaping industry.
Subscribe Free Today
Subscribe   View Sample

Industry Market Trends
Has Got It
  • Latest developments
  • Trends
  • Best practices
  • Opinions & Commentary
Get Ahead. Get IMT.
Subscribe Free Today
Subscribe   View Sample

LCD Digital Dissolved Oxygen Meter - Battery Operated

Kernco Instruments Co., Inc. is pleased to introduce its new LCD digital battery operated dissolved oxygen meter designed to measure dissolved oxygen readings in the field as well as in the laboratory. The DO accuracy is ±1.5% full scale and the temperature accuracy is ±1% full scale.

The 02 measurement range is 0.00 to 19.00 PPM, and temperature range is 0.0° to 50.0°C. These ranges are displayed on an easy to read 3.5 digit LCD readout with 1/2" high numerals. This model features automatic temperature compensation over the range of 0° to 30°C. All adjustments are on the front panel, and they include: zero calibration, slope calibration, and temperature calibration. The 02 adjustment can be made in the air, or for best accuracy can be made in saturated water.

Other features include: the convenient stand by mode keeps current flowing through the probe to give instant readings, no waiting to prepare the instrument for the reading. Uses a 9 volt battery giving 100 hours of service in continuous operation.
Display has a low battery indication. This model uses a polarigraphic type probe with a 9 foot cable, and the probe includes a thermistor for automatic temperature compensation. Model comes with a soft carrying case which will hold the meter,
probe, and bottle of electrolyte.

Dimensions are 7 11/32"L x 3 3/8"W x 2"D, and weight is 1 1/2 lbs.



Contacts:

Sales:
Kernco Instruments Co. Inc.
John Kelly Sales Director
420 Kenazo Ave.
El Paso TX 79928-7339
USA
Phone: 915-852-3375
FAX: 915-852-4084
Send email  E-mail this person

Company Information:
Name: Kernco Instruments Co., Inc.
Address: 420 Kenazo Ave.
City: El Paso
State: TX
ZIP: 79927 7338
Country: USA
Phone: 915-852-3375
FAX: 915-852-4084
http://www.kerncoinstr.com


More New Product News from this company:
Digital Lab Refractometer measures 11.5 x 8.5 x 3.0 in.
Refractometer can hold 14 custom measurement scales.
Digital Refractometer provides 0-65% range.
Digital Tachometer measures rpm, linear speeds, and length.
Tachometer/Stroboscope helps analyze machine behavior.
Gas Detectors feature adjustable setpoints and alarms.
Digital Refractometer has 0-60% concentration level range.
Tachometer measures rpm, fpm, and mpm in 1 second.
Tester measures pH, conductivity, TDS, and temperature.
Pocket Digital Refractometer has 0-53% range.


Click here for copyright permissions!
Copyright 2009 Thomas Publishing Company


 

Post a comment about this story

Name:
E-mail:
(your e-mail address will not be posted)
Comment title:
Comment:
 

Category Advertisements




ThomasNet News Advertisers




Home  |  My ThomasNet News  |  Industry Market Trends  |  Submit Release  |  Advertise  |  Contact News  |  About Us
Brought to you by Thomasnet.com        Browse ThomasNet Directory

Copyright © 2009 Thomas Publishing Company
Terms of Use - Privacy Policy