Quantcast
 
Search for: Search what?
Nov 23, 2009  
 Sections
Latest New Product News
Industry Market Trends
Green & Clean News
Association & Government News
Adhesives and Sealants
Agricultural and Farming Products
Architectural and Civil Engineering Products
Automatic ID
Chemical Processing and Waste Management
Cleaning Products and Equipment
Communication Systems and Equipment
Computer Hardware and Peripherals
Construction Equipment and Supplies
Controls and Controllers
Display and Presentation Equipment
Electrical Equipment and Systems
Electronic Components and Devices
Explosives, Armaments and Weaponry
Fasteners and Hardware
Fluid and Gas Flow Equipment
Food Processing and Preparation
Health, Medical and Dental Supplies and Equipment
HVAC
Labels, Tags, Signage and Equipment
Laboratory and Research Supplies and Equipment
Lubricants
Machinery and Machining Tools
Material Handling and Storage
Materials and Material Processing
Mechanical Components and Assemblies
Mechanical Power Transmission
Mining, Oil Drilling & Refining
Mounting and Attaching Products
Non-Industrial Products
Optics and Photonics
Packaging Products & Equipment
Paints and Coatings
Plant Furnishings and Accessories
Portable Tools
Printing and Duplicating Equipment
Retail and Sales Equipment
Robotics
Safety and Security Equipment
Sensors, Monitors and Transducers
Services
Software
Test and Measuring Instruments
Textile Industry Products
Thermal and Heating Equipment
Timers and Clocks
Transportation Industry Products
Vision Systems
Waste Handling Equipment
Welding Equipment and Supplies
 Press Releases
Products in the News
Company News
Mergers & Acquisitions
People in the News
Literature & Websites
 Resources
News Delivery Options
Browse Categories
Browse Companies
Mobile Edition
PR Resources
Licensing
Advertising
How to Write an effective Press Release
Trade Associations
Small Business Support
MEP
Advertisement
Peracetic Acid  Monitor is used in water disinfection systems.
Peracetic Acid Monitor is used in water disinfection systems.

Click Here to Enlarge Picture

Peracetic Acid Monitor is used in water disinfection systems.


October 29, 2009 - Used for online measurement of peracetic acid (PAA) residuals in disinfection systems, Q45/85 Peracetic Acid Monitor uses membrane-covered polarographic sensor that does not require addition of chemical reagents. It provides real-time measurement of low levels of PAA in solution. Available in flowcell or submersion configurations, device is offered in AC-powered analyzer, loop-powered transmitter, or battery-operated portable versions.

 See related product stories
Remote Monitoring System checks water or air for VOCs.
Portable Water Quality Monitor enables remote logging.
Panel provides online monitoring of drinking water.
At-Line Automation Analyzer targets food process industry.
Drinking Water Analyzer detects pesticides and contaminants.
 See more product news in:
Sensors, Monitors and Transducers
Test and Measuring Instruments
 Tools for you
del.icio.us DIGG  
Facebook Reddit
StumbleUpon Twitter
Print This Page E-Mail Story
Watch_Company  Save Story
Contact company View Company Profile
Company web site 
More news from this company

Advertisement
More Tools and information
Search for suppliers of
Water Quality Monitors
Acid Analyzers
Join the forum discussion at:
 Tools of the Trade
 Newsletters
Your Gateway to a Fast Changing World
Product News Alerts
Receive similar stories and other customized news to keep you in the know on the products shaping industry.
Subscribe Free Today
Subscribe   View Sample

Industry Market Trends
Has Got It
  • Latest developments
  • Trends
  • Best practices
  • Opinions & Commentary
Get Ahead. Get IMT.
Subscribe Free Today
Subscribe   View Sample
 See more related product stories:
Portable Instruments measure conductivity, TDS, pH, heat.
Online Ammonia Monitor helps ensure food safety.
Dissolved Ammonia Monitor provides measurement stability.
Process Analyzer targets food industry.
Algae Monitoring Instrument performs analyses in seconds.
On-Line Monitors target power generation market.
Chart Recorder monitors chlorine residuals in water.
Monitor continuously measures fluoride in potable water.
Monitors measure pollution in industrial water emissions.
Dissolved Sulfide Monitor offers non-contact water readings.
Monitoring System offers online water analysis.
Wireless System remotely monitors water quality.
Liquid Standards Generator handles highly reactive VOCs.
Wireless Modem is suited for remote monitoring.
Water Quality Monitor provides constant surveillance.


Analytical Technology Introduces Peracetic Acid Monitor for Effective Control of Disinfection Systems


Saddleworth, UK (October 23, 2009) Specialist electrochemical sensor manufacturer Analytical Technology Inc (ATi) announces the launch of the Q45/85 Peracetic Acid Monitor. Peracetic acid (PAA) is an extremely strong oxidiser that is employed in a wide range of industries for the disinfection of systems and equipment. Analytical Technology's new Peracetic Acid Monitor enables on-line measurement of residuals of PAA in disinfection systems. A free-of-charge product brochure can be downloaded via www.analyticaltechnology.com.

As peracetic acid produces no harmful breakdown products, it is widely used in the food industry for the disinfection of piping systems and processing equipment. It is also used for spray washing of food products and disinfection of water systems. With any disinfection system, maintaining proper residual levels is essential to pathogen control. Analytical Technology has developed the Q45/85 Peracetic Acid Monitor in order to facilitate reliable chemical control and provide real-time measurement of low levels of PAA in solution.

Analytical Technology's Q45 monitoring systems use a membrane-covered polarographic sensor that does not require the addition of chemical reagents. The Q45/85 Monitor does not contain any moving parts, pumps or motors that can burn out, or tubing breaks that require constant maintenance. Analytical Technology's Peracetic Acid Monitor sensors are available in two configurations, flowcell or submersion. The constant-head flowcell sensor is used to maintain a constant flow rate and pressure at the face of the sensor for flow rates of at least seven gallons per hour. Alternatively a low volume flowcell can be supplied for clean water applications with flow rates of between one and three gallons per hour. The submersion sensor requires flow velocities of at least 0.4ft per second for effective operation.

The new monitor is available as an AC-powered analyser, loop-powered transmitter or battery-operated portable version, ensuring that the monitor is well-suited for almost any peracetic acid measurement. A portable data-logging version is also available for temporary installations or process studies. The Q45/85 monitor is offered with an optional pH sensor input, which allows a single unit to provide both peracetic acid and pH analogue outputs.

For more information on Analytical Technology's new Q45/85 Peracetic Acid Monitor, please call +44(0)1457 873 318, e-mail sales@atiuk.com or visit www.analyticaltechnology.com.


Contacts:

Public Relations:
The Scott Partnership
Eleanor Thouret
1 Whiteside, Station Road
Holmes Chapel, Cheshire
INTL
Phone: 44-0-1477-539539
FAX: 44-0-1477-539540
Send email  E-mail this person

Company Information:
Name: Analytical Technology, Inc.
Address: 680 Hollow Rd.
City: Oaks
State: PA
ZIP: 19426
Country: USA
Phone: 800-959-0299
FAX: 610-917-0992
http://www.analyticaltechnology.com


More New Product News from this company:
Portable Water Quality Monitor enables remote logging.
Dissolved Oxygen Monitor features auto-cleaning system.
Gas Detector reads over 30 gas concentrations.
Panel provides online monitoring of drinking water.
Residual Chlorine Monitor is portable and battery powered.
Monitor detects gas in pharmaceutical industry.
Online Ammonia Monitor helps ensure food safety.
Dissolved Ammonia Monitor provides measurement stability.
Sensors are designed for industrial/municipal applications.

Other News from this company:
Analytical Technology Develops System for Reliable Measurement of Turbidity in Water
Analytical Technology Launches New Web Portal
Analytical Technology Wins Prestigious United Utilities Framework Award
ATi Introduces Brochure to Support its Ground-breaking New Ammonia Monitoring System
ATi Accredited with ISO 9001:2000 Quality Management Certificate
ATi's Dissolved Hydrogen Sulphide Monitor Achieves Accurate Hydrogen Sulphide Measurements in Water
Bristol Water Uses ATi's Innovative Dissolved Ozone Monitor to Improve Drinking Water Quality
ATi Introduces New FOC Process Application Note about Reagent-Free Residual Chlorine Measurement



Click here for copyright permissions!
Copyright 2009 Thomas Publishing Company


 

Post a comment about this story

Name:
E-mail:
(your e-mail address will not be posted)
Comment title:
Comment:
 

Home  |  My ThomasNet News  |  Industry Market Trends  |  Submit Release  |  Advertise  |  Contact News  |  About Us
Brought to you by Thomasnet.com        Browse ThomasNet Directory

Copyright © 2009 Thomas Publishing Company
Terms of Use - Privacy Policy