|
|
|
|
Benchtop LC/MS System analyzes complex samples.
August 18, 2009 -
With Agilent 6540 UHD Quadrupole Time-of-Flight LC/MS System, researchers can profile, identify, characterize, and quantify low molecular-weight compounds and biomolecules. Ion Beam Compression and Enhanced Mirror Technology produce ultra-high-definition 500 ppb mass accuracy and up to 40,000 mass resolution while maintaining benchtop format. Data acquisition rates up to 20 spectra/sec ensure compatibility with Agilent 1290 UHPLC and high-throughput methods.
|
|
|
| |
| |
|
Advertisement
|
|
|
Newsletters |
Your Gateway to a Fast
Changing World
Product News Alerts |
 |
Receive similar stories and other customized
news to keep you in the know on the products shaping
industry. |
Subscribe Free Today
Subscribe View
Sample |
Industry
Market Trends
Has Got It |
- Latest developments
- Trends
- Best practices
- Opinions & Commentary
|
 |
Get Ahead.
Get IMT.
Subscribe Free Today
Subscribe View
Sample |
|
|
|
|
Agilent Technologies Introduces Ultra-High-Definition (UHD) Accurate-Mass Q-TOF LC/MS for Fast, High-Confidence Analysis of Complex Samples
PHILADELPHIA, ASMS Conference on Mass Spectrometry, June 1, 2009
Agilent Technologies Inc. (NYSE: A) today introduced the Agilent 6540 Ultra- High-Definition (UHD) Accurate-Mass Quadrupole Time-of-Flight (Q-TOF) liquid chromatography/mass spectrometry (LC/MS) system. This benchtop system offers superior data quality and advanced analytical capabilities, enabling researchers to profile, identify, characterize and quantify low molecular-weight compounds and biomolecules with greater confidence.
The Agilent 6540 Q-TOF is by far the highest-performing benchtop Q-TOF on the market, delivering much better performance than comparable Q-TOF products without the inherent trade-offs in speed, dynamic range, isotopic fidelity and mass range that are required by orbitrap-based systems. Innovative Ion Beam Compression (IBC) and Enhanced Mirror Technology (EMT) produce ultra-high-definition mass accuracy and mass resolution while maintaining a benchtop format.
"While others have pursued a 'bigger must be better' approach to TOF flight tube development, Agilent has used advanced engineering to dramatically improve performance and maintain a benchtop-instrument format." said Ken Miller, Agilent senior global marketing director for LC/MS. "We've achieved huge gains in mass accuracy and resolution while maintaining our industry-leading sensitivity and dynamic range. And the system can run fast to generate accurate mass MS and MS/MS data for UHPLC analyses without the resolution loss suffered by orbitraps. This is the perfect system for state-of-the-art qualitative analysis in support of proteomic, metabolomic or non-targeted food safety and environmental studies."
6540 UHD Q-TOF System Features
The new 6540 UHD Q-TOF delivers industry-leading performance in the most important categories:
o Agilent Jet Stream thermal-gradient-focusing technology provides high femtogram MS/MS sensitivity and identification of trace-level compounds;
o up to 500 ppb mass accuracy improves confidence and reduces false positives;
o fast data acquisition rates of up to 20 spectra/second ensure maximum compatibility with Agilent 1290 UHPLC and high-throughput methods;
o up to five orders of in-spectrum dynamic range improves detection of trace-level targets in the presence of high-abundance compounds;
o up to 40,000 mass resolution distinguishes target analytes from interferences; and
o high-definition isotopic fidelity confirms molecular formulas with greater confidence.
Agilent also offers application-specific software packages to take full advantage of this exceptional data quality to improve results from proteomics, metabolomics and common screening applications:
o NEW Mass Profiler Professional software for sophisticated differential analysis and profiling of complex sample sets;
o bioconfirm software for characterization and confirmation of intact protein and oligonucleotide molecules;
o METLIN Personal Database, a searchable metabolomics database of more than 23,000 endogenous metabolites and lipids;
o MassHunter Personal Compound databases for pesticides (more than 1,600 compounds) and forensic/ toxicology (more than 7,500 compounds);
o Spectrum Mill Workstation software for protein database searching; and
o MassHunter Metabolite ID software to identify drug metabolites.
The 6540 UHD Accurate Mass Q-TOFs can be ordered July 1.
About Agilent Technologies
Agilent Technologies Inc. (NYSE: A) is the world's premier measurement company and a technology leader in communications, electronics, life sciences and chemical analysis. The company's 19,000 employees serve customers in more than 110 countries. Agilent had net revenue of $5.8 billion in fiscal year 2008. Information about Agilent is available on the Web at www.agilent.com.
Contacts:
General Information:
Stuart Matlow
USA
Phone: 408-553-7191
E-mail this person
Company Information:
Name: Agilent Technologies, Inc
Address: 5301 Stevens Creek Blvd.
City: Santa Clara
State: CA
ZIP: 95051
Country: USA
Phone: 650-752-5000
http://www.agilent.com
|
Other News from this company: |
 |
Agilent Technologies Offers 4-Tap De-Emphasis Converter, Highest Flexible SSC Injection
|
 |
Agilent Technologies Unveils Newest Solutions for Microwave, RF, Wireless, Radar Test at 2009 European Microwave Conference
|
 |
Agilent Technologies' 1Gxx MMIC Products Now Available
|
 |
Agilent Technologies Announces Industry's First Complete, Front-to-Back Solution for MMIC, RF Module Design
|
 |
Agilent Technologies Offers MATLAB Software with Agilent Sampling Scopes
|
 |
Agilent Technologies, Net-O2 Technologies Announce World's First MEF 21 Conformance Test Suite
|
 |
Agilent Technologies' Updated Firmware for DC Power Analyzer Incorporates Customer-Recommended Enhancements
|
 |
Agilent Technologies to Show New Test Solutions for Microwave, RF, Wireless and Radar at 2008 European Microwave Conference
|
 |
Agilent Technologies and T-Tech Announce Agreement on RF Printed Circuit Board Design and Prototyping
|
 |
Agilent Technologies Presents Web Seminar on Logic Analyzer Basics
|
 |
Agilent Technologies' E2960B Series for PCI Express® Protocol Test Now Includes Module for Active State Power Management Testing
|
 |
Agilent Technologies Introduces Free Phase-Locked Loop Analysis Software
|
 |
Agilent Technologies' Array Structure Parametric Test Solution Wins Best Product Award from Semiconductor International
|
 |
Agilent Technologies Advanced Design System EDA Software Chosen by Inphi for Memory Interface Chip Design
|
 |
Agilent Technologies' New PSA and MXA Analysis Capabilities Deliver Powerful Analysis Functionality to R&D Engineers
|
 |
Agilent Technologies' New Family of USB Modular Instruments Provides Flexible, Affordable Solutions for Electronic Functional Test
|
 |
Agilent Technologies' Infiniium 90000A Series 13-GHz Oscilloscope Approved by PCI-SIG® for PCI Express® 2.0 Compliance Testing
|
 |
Agilent Technologies' DC Power Analyzer Wins Additional Industry Awards
|
 |
Agilent Technologies Announces Availability of New Self-Guided N8300A Wireless Networking Test Set Demonstration Guide for Testing WiMAX(TM) Devices
|
 |
Agilent Technologies' Test, Inspection Innovations Win Awards at Major Industry Tradeshows
|
|
|
|
|
|
 |
ThomasNet News Advertisers
|
 |
|