Quantcast
 
Search for: Search what?
Nov 25, 2009  
 Sections
Latest New Product News
Industry Market Trends
Green & Clean News
Association & Government News
Adhesives and Sealants
Agricultural and Farming Products
Architectural and Civil Engineering Products
Automatic ID
Chemical Processing and Waste Management
Cleaning Products and Equipment
Communication Systems and Equipment
Computer Hardware and Peripherals
Construction Equipment and Supplies
Controls and Controllers
Display and Presentation Equipment
Electrical Equipment and Systems
Electronic Components and Devices
Explosives, Armaments and Weaponry
Fasteners and Hardware
Fluid and Gas Flow Equipment
Food Processing and Preparation
Health, Medical and Dental Supplies and Equipment
HVAC
Labels, Tags, Signage and Equipment
Laboratory and Research Supplies and Equipment
Lubricants
Machinery and Machining Tools
Material Handling and Storage
Materials and Material Processing
Mechanical Components and Assemblies
Mechanical Power Transmission
Mining, Oil Drilling & Refining
Mounting and Attaching Products
Non-Industrial Products
Optics and Photonics
Packaging Products & Equipment
Paints and Coatings
Plant Furnishings and Accessories
Portable Tools
Printing and Duplicating Equipment
Retail and Sales Equipment
Robotics
Safety and Security Equipment
Sensors, Monitors and Transducers
Services
Software
Test and Measuring Instruments
Textile Industry Products
Thermal and Heating Equipment
Timers and Clocks
Transportation Industry Products
Vision Systems
Waste Handling Equipment
Welding Equipment and Supplies
 Press Releases
Products in the News
Company News
Mergers & Acquisitions
People in the News
Literature & Websites
 Resources
News Delivery Options
Browse Categories
Browse Companies
Mobile Edition
PR Resources
Licensing
Advertising
How to Write an effective Press Release
Trade Associations
Small Business Support
MEP
Advertisement
Mini Datalogger takes measurements for over 1 year.
Mini Datalogger takes measurements for over 1 year.

Click Here to Enlarge Picture

Mini Datalogger takes measurements for over 1 year.


May 1, 2009 - Equipped with 900 mAh lithium-polymer battery, Model MSR145 measures and records humidity, temperature, pressure, light, and position/acceleration over 1 year period. Integrated light sensor, with 0-300 lux and max sensitivity of 580 nm, allows brightness to be constantly monitored. Offering selectable measurement rates up to 50 values/sec, logger enables all measurement parameters to be transferred to PC during recording and after completion of measurement process.

 See related product stories
Data Logger enables complete temperature profiling.
Temperature/Process Data Loggers come in compact package.
Data Logger enables accurate chemical flow monitoring.
Vehicle Data Logger acquires OBD and CAN bus data.
Data Loggers feature universal inputs.
 See more product news in:
Test and Measuring Instruments
 Tools for you
del.icio.us DIGG  
Facebook Reddit
StumbleUpon Twitter
Print This Page E-Mail Story
Watch_Company  Save Story
Contact company
Company web site 
More news from this company

Advertisement
More Tools and information
Search for suppliers of
Data Loggers & Data Logging Equipment
Temperature Recorders
Pressure Recorders
Humidity Recorders
Join the forum discussion at:
 Tools of the Trade
 Wired In
 Newsletters
Your Gateway to a Fast Changing World
Product News Alerts
Receive similar stories and other customized news to keep you in the know on the products shaping industry.
Subscribe Free Today
Subscribe   View Sample

Industry Market Trends
Has Got It
  • Latest developments
  • Trends
  • Best practices
  • Opinions & Commentary
Get Ahead. Get IMT.
Subscribe Free Today
Subscribe   View Sample
 See more related product stories:
Thermocouple Data Logger features integrated LCD display.
Wireless Sensor Gateway helps centralize data acquisition.
Data Logger measures temperature and humidity.
Process Monitor provides predictive maintenance.
Temperature Data Loggers feature wireless operation.
Mini Shock/Vibration Logger takes 1,000 measurements/sec.
Web Gateway provides remote monitoring and control,
Data Logger measures pressures up to 5,000 psi.
Temperature/Humidity Logger features USB connectivity.
Data Logging System suits high temperature food processing.
Multi-Gas Monitor targets industrial and fire applications.
Dynamic Current Loggers provide 8,000 samples/sec.
Data Logger permits multiple logs to be recorded/read back.
DAQ/Reporting System is offered with Modbus interface.
Data Loggers use thermocouple or carbon monoxide sensor.
Remote Access/Monitoring System uses cellular networks.
Machinery Data Logging System can store up to 32,767 events.
Pressure Calibrator records parameters at 10 times/sec.
Data Logger records for up to 682 days at 1 min reading rate.
Temperature/Humidity Data Logger features built-in display.


The MSR145 Datalogger Now Has 5x More Capacity


Henggart, April 2009 - Now you can easily measure and record humidity, temperature, pressure, light and position/acceleration simultaneously over a whole year. The Swiss Engineering firm MSR Electronics GmbH now offers the award-winning MSR145 mini datalogger with a 900 mAh lithium-polymer battery and light sensor.

Long-term measurements are often inevitable in order to get to the root of a problem. Only clear results allow the user to make a correct evaluation. In order to accommodate these requirements we have fitted the MSR145 datalogger with a 900 mAh battery providing a five times greater capacity over the standard battery. This allows you to easily record measurement parameters over a whole year and even over a period of up to two years, depending on the measurement rate.

New: Now also available with light sensor

The new light sensor integrated into the MSR145 mini datalogger allows for the brightness of a room to be constantly monitored. Combined with other relevant measurement parameters such as humidity, temperature, air pressure and motion, the users receive important data enabling them to keep costs in check and control energy consumption. This is a recurring issue for lessors of public buildings, open plan offices and between private tenants and landlords: Is it possible for the lessor to invest in optimal energy consumption measures and achieve longer-term depreciation of this investment? How can the tenant/lessee actively contribute to keeping ancillary costs down? Where and how exactly can savings be achieved? Using the light sensor (0 - 300 lux, max. sensitivity at 580 nm) for example, it is possible to monitor whether or not the light is turned off in commonly used rooms. In addition, the MSR145 is capable of detecting if shutters are closed - one method of causing the air-conditioning system to consume less power whilst maintaining the indoor climate at the predefined value. Aside from monetary and ecological aspects, well-being and comfort in rooms and buildings, particularly in schools, are of crucial importance too. After all, success and health depend to a large extent on a comfortable indoor climate. Dataloggers such as the MSR145 provide objective measurement values, giving you peace of mind with regard to the condition of your building.

Facilitates quality monitoring of critical products

The light, 3-axis acceleration, temperature, humidity and pressure sensors of the mini datalogger are also used in industrial applications. Today, datalogging is an essential requirement from manufacture right through delivery of a product to the end customer. The MSR Electronics dataloggers record all stages of production and transport so they can be traced. Meaningful data helps users to ensure the quality of their goods while minimising cost and safety risks. If for example, you want to find out if and when a package has been opened (by customs for example), the sensor will provide you with exact data through brightness logging.

MSR145: Small modular multi-talent

Currently there are no comparable dataloggers available that combine five measurement parameters in one small and handy single unit. A recording capacity of 2m measurement parameters means superior efficiency. Furthermore, the MS145 comes with optional 2 or 4 analogue inputs to connect traditional sensors. A sealed model is also available.
As Wendelin Egli, Dipl.-Ing. HTL, Head of Development of MSR Electronics GmbH says: "The user selects the housing, battery, measurement parameters, number of internal sensors, any external sensors, plus any additional analogue inputs he requires and receives a custom datalogger built to his exact specifications." Freely selectable measurement rates of up to 50 values per second guarantee uninterrupted documentation of rapid processes. All measurement parameters can be quickly transferred to a PC, both during recording and after completion of the measurement process, using a USB interface. The user-friendly data analysis software is offered free of charge to the customer.

Technical information and international sales points: www.msr.ch

About MSR Electronics GmbH

Based in Henggart, Switzerland, MSR Electronics GmbH was established in 2006 following a management buyout of prospective concepts ag (Zurich, Switzerland). All activities of the MSR unit (MSR = Modular Signal Recorder) such as development, production and marketing as well as sales and support of the MSR dataloggers were taken over and intensified by MSR Electronics GmbH.

The firm's core competency is the development and sale of standardised and customised dataloggers for a wide range of different applications. Among MSR Electronics' customers are well-known companies such as Festo, Alstom, Novartis, W.L. Gore & Associates, EMPA, the Swiss Air Rescue Service Rega and many more.

In March 2009, the MSR145 Analogue datalogger was voted first place by readers of the German trade magazine "Elektronik" - becoming the "Product of the Year 2009" in the "Measurement technology" category.

MSR Electronics GmbH

Wendelin Egli, Managing director

Phone +41 52 316 25 55

Fax +41 52 316 35 21

w.egli@msr.ch

www.msr.ch


Contacts:

General Information:
Wendelin Egli Managing Director
INTL
Phone: +41 52 316 25 55
FAX: +41 52 316 35 21
Send email  E-mail this person

Company Information:
Name: MSR Electronics GmbH
Address: Oberwilerstrasse 16
City: Henggart
ZIP: CH-8444
Country: Switzerland
Phone: +41 52 316 25 55
FAX: +41 52 316 35 21
http://www.msr.ch/en


More New Product News from this company:
Mini Datalogger features 4 integrated sensors.
Mini Datalogger stores over 2,000,000 measurement parameters.


Click here for copyright permissions!
Copyright 2009 Thomas Publishing Company


 

Post a comment about this story

Name:
E-mail:
(your e-mail address will not be posted)
Comment title:
Comment:
 

Category Advertisements




Home  |  My ThomasNet News  |  Industry Market Trends  |  Submit Release  |  Advertise  |  Contact News  |  About Us
Brought to you by Thomasnet.com        Browse ThomasNet Directory

Copyright © 2009 Thomas Publishing Company
Terms of Use - Privacy Policy