Quantcast
 
Search for: Search what?
Nov 25, 2009  
 Sections
Latest New Product News
Industry Market Trends
Green & Clean News
Association & Government News
Adhesives and Sealants
Agricultural and Farming Products
Architectural and Civil Engineering Products
Automatic ID
Chemical Processing and Waste Management
Cleaning Products and Equipment
Communication Systems and Equipment
Computer Hardware and Peripherals
Construction Equipment and Supplies
Controls and Controllers
Display and Presentation Equipment
Electrical Equipment and Systems
Electronic Components and Devices
Explosives, Armaments and Weaponry
Fasteners and Hardware
Fluid and Gas Flow Equipment
Food Processing and Preparation
Health, Medical and Dental Supplies and Equipment
HVAC
Labels, Tags, Signage and Equipment
Laboratory and Research Supplies and Equipment
Lubricants
Machinery and Machining Tools
Material Handling and Storage
Materials and Material Processing
Mechanical Components and Assemblies
Mechanical Power Transmission
Mining, Oil Drilling & Refining
Mounting and Attaching Products
Non-Industrial Products
Optics and Photonics
Packaging Products & Equipment
Paints and Coatings
Plant Furnishings and Accessories
Portable Tools
Printing and Duplicating Equipment
Retail and Sales Equipment
Robotics
Safety and Security Equipment
Sensors, Monitors and Transducers
Services
Software
Test and Measuring Instruments
Textile Industry Products
Thermal and Heating Equipment
Timers and Clocks
Transportation Industry Products
Vision Systems
Waste Handling Equipment
Welding Equipment and Supplies
 Press Releases
Products in the News
Company News
Mergers & Acquisitions
People in the News
Literature & Websites
 Resources
News Delivery Options
Browse Categories
Browse Companies
Mobile Edition
PR Resources
Licensing
Advertising
How to Write an effective Press Release
Trade Associations
Small Business Support
MEP
Advertisement
Flow Sensor handles temperatures up to 350°C.
Flow Sensor handles temperatures up to 350°C.

Click Here to Enlarge Picture

Flow Sensor handles temperatures up to 350°C.


June 12, 2008 - Offering measuring range of 0.2-20 m/sec, Model SS 20.60 HT provides digital and analog output and uses status indicator to display information about current flow velocity. Modular design enables sensor to be supplied with field bus interface. Able to measure free air and guided air in ducts from 25-1.000 mm, sensor is suited for mass flow control of combustion processes, burner control, flow measurement of process gases, and volume flow measurement of test stands.

(Archive News Story - Products mentioned in this Archive News Story may or may not be available from the manufacturer.)

 See related product stories
Turbine Flow Sensors utilize high resolution IR technology.
Level and Flow Monitor provides isolated 4-20 mA output.
Turbine Flow Sensors target low flow applications.
Flow Sensor has measuring range of 0-50 m/s.
Air Flow Measuring Probes are suited for duct applications.
 See more product news in:
HVAC
Sensors, Monitors and Transducers
Test and Measuring Instruments
 Tools for you
del.icio.us DIGG  
Facebook Reddit
StumbleUpon Twitter
Print This Page E-Mail Story
Watch_Company  Save Story
Company web site 
More news from this company

Advertisement
More Tools and information
Search for suppliers of
Flow Sensors
Air Flow Sensors
Join the forum discussion at:
 Tools of the Trade
 Newsletters
Your Gateway to a Fast Changing World
Product News Alerts
Receive similar stories and other customized news to keep you in the know on the products shaping industry.
Subscribe Free Today
Subscribe   View Sample

Industry Market Trends
Has Got It
  • Latest developments
  • Trends
  • Best practices
  • Opinions & Commentary
Get Ahead. Get IMT.
Subscribe Free Today
Subscribe   View Sample
 See more related product stories:
Viscosity Sensor is suited for thick and viscous fluids.
Viscosity Sensors can be completely immersed in fluid.
FDA-Compliant Flow Sensor delivers repeatable results.
Pressure Sensors suit furnace modulation applications.
Turbine Flow Sensor can handle temperatures up to 80°C.
Coriolis Flowmeter is designed for loop-powered processes.
Blind Flow Sensors feature paddlewheel sensing technology.
Insertion Flow Sensor permits hot-tap access to pipe stream.
Air Flow Sensor comes with integrated dual color display.
Paddlewheel Flow Sensor has 1-1,000 Hz input frequency range.
Thermal Flow Sensor can withstand explosive environment.
MEMS Flow Sensor suits HVAC air handling equipment.
Loop-Powered Ultrasonic Sensors offer internal calculation.
Viscosity Sensor obtains lab-compatible results.
Insertion Flow Sensor features three output options.
Metal Magmeter permits hot-tap access to pipe stream.
Flow Sensor monitors laminar flow in cleanrooms.
Air and Gas Flow Sensor has 200 m/s measuring range.
Level Sensor tracks inventory in smaller tanks and silos.
Flow Sensors utilize paddlewheel technology.


SCHMIDT® Flow-Sensor SS 20.60 HT, for High Temperatures Up To 350°C


SCHMIDT® Technology has developed a high temperature version of the SS 20.60 for the application in operating temperature up to 350°C - for short time even 400°C.
The sensor differs formally in the white ceramic tip. Most of the modifications have been made inside the sensor and the modules are designed according to the elevated specification.

A complete new designed electronic unit processes the results of measurement and provides a digital and analog output. The new status indicator displays information about the current flow velocity and the sensors status. The measuring signal output of the temperature is new as well.

Due to the modular concept the sensor can be supplied with field bus interface. The sensor with field bus interface delivers ready prepared measuring values like Kg/hr or m³/min and thus disbur-dens the supervising PLC. Additionally the sensor gives access to its status information and allows the PLC to inform the user about defects of the sensor.

Applications:

Mass flow-control of combustion processes, burner control, flow measurement of process gases, volume flow measurement of test stands, Measurement of flow velocity in drying plants and sterilizing processes.

Technical data:

Design: Immersion sensor with attached transformer

Application: Free air and guided air in ducts from 25 to 1.000 mm

Measuring range: 0,2 ... 20 m/s

Pressure: atmospheric

Temperature: 0 ... 350 °C

Mounting: ½ inch thread

Analog output: 0..10V, 0/4 .. 20 mA

Digital output: 10 bis 100 Hz

Power supply: 24 VDC / approx. 150 mA

Field bus version: Profibus DP, Device Net.

SCHMIDT Technology GmbH, Feldbergstr. 1, 78112 St. Georgen,Tel.: +49/7724/899-0, Fax:+49/7724/899101, Email:, Homepage: www.schmidttechnology.de

Company Information:
Name: SCHMIDT Technology GmbH
Address: Feldbergstraße 1
City: St. Georgen
ZIP: D-78112
Country: Germany
Phone: 0 77 24 / 8 99-0
FAX: 0 77 24 / 8 99-101
http://www.schmidttechnology.de


More New Product News from this company:
Flow Sensor has measuring range of 0-50 m/s.
Thermal Flow Sensor can withstand explosive environment.
Flow Sensor monitors laminar flow in cleanrooms.
Air and Gas Flow Sensor has 200 m/s measuring range.
Air/Gas Flow Sensor features integrated Fieldbus interface.
Flow Sensor detects flow direction.


Click here for copyright permissions!
Copyright 2009 Thomas Publishing Company


 

Post a comment about this story

Name:
E-mail:
(your e-mail address will not be posted)
Comment title:
Comment:
 

Category Advertisements




ThomasNet News Advertisers



Visit Our New Web Site

Home  |  My ThomasNet News  |  Industry Market Trends  |  Submit Release  |  Advertise  |  Contact News  |  About Us
Brought to you by Thomasnet.com        Browse ThomasNet Directory

Copyright © 2009 Thomas Publishing Company
Terms of Use - Privacy Policy