Quantcast
 
Search for: Search what?
Nov 25, 2009  
 Sections
Latest New Product News
Industry Market Trends
Green & Clean News
Association & Government News
Adhesives and Sealants
Agricultural and Farming Products
Architectural and Civil Engineering Products
Automatic ID
Chemical Processing and Waste Management
Cleaning Products and Equipment
Communication Systems and Equipment
Computer Hardware and Peripherals
Construction Equipment and Supplies
Controls and Controllers
Display and Presentation Equipment
Electrical Equipment and Systems
Electronic Components and Devices
Explosives, Armaments and Weaponry
Fasteners and Hardware
Fluid and Gas Flow Equipment
Food Processing and Preparation
Health, Medical and Dental Supplies and Equipment
HVAC
Labels, Tags, Signage and Equipment
Laboratory and Research Supplies and Equipment
Lubricants
Machinery and Machining Tools
Material Handling and Storage
Materials and Material Processing
Mechanical Components and Assemblies
Mechanical Power Transmission
Mining, Oil Drilling & Refining
Mounting and Attaching Products
Non-Industrial Products
Optics and Photonics
Packaging Products & Equipment
Paints and Coatings
Plant Furnishings and Accessories
Portable Tools
Printing and Duplicating Equipment
Retail and Sales Equipment
Robotics
Safety and Security Equipment
Sensors, Monitors and Transducers
Services
Software
Test and Measuring Instruments
Textile Industry Products
Thermal and Heating Equipment
Timers and Clocks
Transportation Industry Products
Vision Systems
Waste Handling Equipment
Welding Equipment and Supplies
 Press Releases
Products in the News
Company News
Mergers & Acquisitions
People in the News
Literature & Websites
 Resources
News Delivery Options
Browse Categories
Browse Companies
Mobile Edition
PR Resources
Licensing
Advertising
How to Write an effective Press Release
Trade Associations
Small Business Support
MEP
Advertisement
Calorimeter ensures batch-to-batch curing consistency.
Calorimeter ensures batch-to-batch curing consistency.

Calorimeter ensures batch-to-batch curing consistency.


December 9, 2005 - Featuring nominal sensitivity of 3.0 µV/BTU/ft²-hr, TFC-9000(TM) Thin Film Calorimeter quantitatively measures curability of inks, coatings, and adhesives. Pushbutton-initiated process measures exothermic heat reaction from polymerizing sample and analyzes incoming data. Test measures shelf life of stored inks and evaluates older inks to determine if they still perform to requirements. Upon test completion, stand-alone unit displays key measured test results in LCDs.

(Archive News Story - Products mentioned in this Archive News Story may or may not be available from the manufacturer.)

 See related product stories
Reaction Calorimeter enables online heat data measurement.
Thin-Film Calorimeter tests inks, coatings, and adhesives.
 See more product news in:
Test and Measuring Instruments
 Tools for you
del.icio.us DIGG  
Facebook Reddit
StumbleUpon Twitter
Print This Page E-Mail Story
Watch_Company  Save Story
View Company Profile
Company web site 
More news from this company

Advertisement
More Tools and information
Search for suppliers of
Calorimeters
Join the forum discussion at:
 Tools of the Trade
 Newsletters
Your Gateway to a Fast Changing World
Product News Alerts
Receive similar stories and other customized news to keep you in the know on the products shaping industry.
Subscribe Free Today
Subscribe   View Sample

Industry Market Trends
Has Got It
  • Latest developments
  • Trends
  • Best practices
  • Opinions & Commentary
Get Ahead. Get IMT.
Subscribe Free Today
Subscribe   View Sample


TFC9000 ThinFilm Calorimeter


Is it the Inks or is it the Lamps? Know for Sure with the Thin Film Calorimeter.

You need a radiometer to ensure the performance and curing effectiveness of your UV lamps. So, how do you ensure the same of your inks, coatings and adhesives? Up until now, it was mostly guesswork. If you had curing problems and had ruled out your UV lamps as the culprit, your next target was most likely your chemistry. CON-TROL-CURE's Thin Film Calorimeter (TFC) allows you to quantitatively measure the curability of your inks, coatings and adhesives.

The TFC-9000(TM) qualifies your inks, coatings and adhesives curability and ensures that they are curing consistently, batch-to-batch. Now you can test the shelf life of stored inks and evaluate older inks to know conclusively if they still perform to your expectations. Less wasted material translates into greater savings and profits.

The TFC-9000 measures the exothermic heat reaction from a polymerizing sample through a highly sensitive sensor. It performs a rapid analysis of the incoming data to produce meaningful results. Once the green "start" button is selected, the curing and evaluation process commences:
o Temperature recording starts
o The UV LED lamp automatically turns on
o The sample is cured
o Peak temperature reaction from the cured sample is reached and displayed
o Once the temperature reaches 75% of the peak, the lamp automatically shuts off

Upon successful test completion, the TFC-9000 displays key measured test results as indicated in the LCD displays:

o Heat Flux
o Peak Value of Heat (in BTU's)
o Total Test Time
o Slope of the Curve for "Time to Peak" vs. "Heat Generated"
o Current Temperature
o Total Heat (in BTU's/Hour)

The TFC-9000 works as a stand-alone measurement system or can be connected to a computer through a serial port. The captured data can be exported and plotted to an Excel graph for quick and easy analysis.

Surprisingly, there is no analytical tool which can quantitatively characterize the photopolymerization rates of pigmented UV inks. Pigmented UV curable coatings typically have reduced photopolymerization rates because the pigments absorb and scatter incident UV radiation. As a consequence, the photoinitiator efficiency is decreased and application thickness is limited to thin-films. In addition, commercial UV curable inks consist of pigment dispersed in reactive oligomers. The resultant concentration of reactive groups is low and consequently small quantities of heat are released upon polymerization making characterization difficult.

Evaluating curing characteristics by using calorimetry is advantageous because measurements are not affected by crosslinking reactions and they offer direct measurement of the polymerization rate. A unique benefit of the TFC-9000(TM) is the ability to accurately measure a very small stimulus. This sensitivity, unavailable in much more expensive evaluation instruments, makes possible the quantitative analysis of photopolymerizable systems which evolve a small amount of heat. Direct implications of this phenomenon include characterization of films on the nano/micro size scale and thin pigmented UV curable ink formulations.

This instrument's precision and high sensitivity allow it to record exotherm reactions on films as thin as 2 micrometers. With a high heat tolerance, the TFC-9000(TM) is ideal for heated sample testing. The sensor has an upper temperature limit of 400°F (205°C.)

Note: The system is sold complete with the UV LED lamp. If a different UV source is required, various UV lamp options are available for use with the TFC-9000 system.

SPECIFICATIONS:
Dimensions: 12"W x 11.25"L x 6.25"H (30.5 cm x 28.6 cm x 15.9cm)
System Weight: 14.5 lbs (2.83 kg)
Sensor Resistance: 300 Ohms (Approx.)
Sensor Lead Wires: 10' (3.1m) Solid copper, teflon insulated
Nominal Sensitivity: 3.0 µV/Btu/Ft²-Hr
Max Rec'd Heat Flux: 30,000 Btu/Ft²Hr
Response Time: 0.6 sec
Temperature Limit: 400°F (205°C)
Thermal Capacitance:0.03 Btu per Ft²-°F
Thermal Resistance: 0.01 °F per Btu/Ft²-Hr

Company Information:
Name: UV Process Supply, Inc.
Address: 1229 W. Cortland
City: Chicago
State: IL
ZIP: 60614-4805
Country: USA
Phone: 773-248-0099
FAX: 773-880-6647
http://www.uvprocess.com


More New Product News from this company:
Strips and Labels indicate accumulated UV light dosage.
UV Curing Lamp covers expansive area.
UV Strips and Labels provide visual indication of UV dose.
UV Intensity Labels measure UV doses from 0-1,500 mJ/cm².
Photochromatic Strips measure UV light dosage.
Spectrodensitometer measures density/colorimetry functions.
Color Density Meter suits pressroom QC applications.
Dot Meters capture and adjust images with one button.
Radiometers have compact 5.5 in. dia x ½ in. high design.

Other News from this company:
Quantitative Analysis of UV LED Performance by the TFC-9000(TM)
UV Process Supply Releases 'Maintaining UV Curing Equipment' Manual



Click here for copyright permissions!
Copyright 2009 Thomas Publishing Company


 

Post a comment about this story

Name:
E-mail:
(your e-mail address will not be posted)
Comment title:
Comment:
 

Category Advertisements




ThomasNet News Advertisers


Surface Preparation Equipment, Parts and Service wheelabratorgroup.com



Sethco - Corrosion Resistant Pumps for Caustics, Acids, Alkalis & Solvents

Home  |  My ThomasNet News  |  Industry Market Trends  |  Submit Release  |  Advertise  |  Contact News  |  About Us
Brought to you by Thomasnet.com        Browse ThomasNet Directory

Copyright © 2009 Thomas Publishing Company
Terms of Use - Privacy Policy