Quantcast
 
Search for: Search what?
Nov 26, 2009  
 Sections
Latest New Product News
Industry Market Trends
Green & Clean News
Association & Government News
Adhesives and Sealants
Agricultural and Farming Products
Architectural and Civil Engineering Products
Automatic ID
Chemical Processing and Waste Management
Cleaning Products and Equipment
Communication Systems and Equipment
Computer Hardware and Peripherals
Construction Equipment and Supplies
Controls and Controllers
Display and Presentation Equipment
Electrical Equipment and Systems
Electronic Components and Devices
Explosives, Armaments and Weaponry
Fasteners and Hardware
Fluid and Gas Flow Equipment
Food Processing and Preparation
Health, Medical and Dental Supplies and Equipment
HVAC
Labels, Tags, Signage and Equipment
Laboratory and Research Supplies and Equipment
Lubricants
Machinery and Machining Tools
Material Handling and Storage
Materials and Material Processing
Mechanical Components and Assemblies
Mechanical Power Transmission
Mining, Oil Drilling & Refining
Mounting and Attaching Products
Non-Industrial Products
Optics and Photonics
Packaging Products & Equipment
Paints and Coatings
Plant Furnishings and Accessories
Portable Tools
Printing and Duplicating Equipment
Retail and Sales Equipment
Robotics
Safety and Security Equipment
Sensors, Monitors and Transducers
Services
Software
Test and Measuring Instruments
Textile Industry Products
Thermal and Heating Equipment
Timers and Clocks
Transportation Industry Products
Vision Systems
Waste Handling Equipment
Welding Equipment and Supplies
 Press Releases
Products in the News
Company News
Mergers & Acquisitions
People in the News
Literature & Websites
 Resources
News Delivery Options
Browse Categories
Browse Companies
Mobile Edition
PR Resources
Licensing
Advertising
How to Write an effective Press Release
Trade Associations
Small Business Support
MEP
Advertisement
Plasma Decapsulation System uses CO<sub>2</sub> to remove fillers.
Plasma Decapsulation System uses CO2 to remove fillers.

Click Here to Enlarge Picture

Plasma Decapsulation System uses CO2 to remove fillers.


September 22, 2004 - Able to process wafers as large as 200 mm, FA-2000 Fillerblast(TM) system is suited for decapsulation and depassivation of packaged devices with metallization in ICs and organic substrates in packaging. Reactive ion etcher eliminates use of wet acids. Manifold forms dry ice, which acts as fine abrasive effective in removing filler buildup, while plasma maintains constant etch rate for efficient removal of molding material. Etch rates for many compounds are more than 1 mil/hr.

(Archive News Story - Products mentioned in this Archive News Story may or may not be available from the manufacturer.)

 See related product stories
Abatement System features microwave plasma and wet scrubber.
Plasma System is suited for high-volume PCB processing.
 See more product news in:
Machinery and Machining Tools
Packaging Products & Equipment
 Tools for you
del.icio.us DIGG  
Facebook Reddit
StumbleUpon Twitter
Print This Page E-Mail Story
Watch_Company  Save Story
Contact company View Company Profile
Company web site 
More news from this company

Advertisement
More Tools and information
Search for suppliers of
Plasma Etching Systems
 Newsletters
Your Gateway to a Fast Changing World
Product News Alerts
Receive similar stories and other customized news to keep you in the know on the products shaping industry.
Subscribe Free Today
Subscribe   View Sample

Industry Market Trends
Has Got It
  • Latest developments
  • Trends
  • Best practices
  • Opinions & Commentary
Get Ahead. Get IMT.
Subscribe Free Today
Subscribe   View Sample


FA-2000 Plasma Decapsulation System


Anatech LTD introduces its FA-2000 reactive ion etcher for decapsulation and depassivation of packaged devices. New device technologies include metallization in integrated circuits and organic substrates in packaging. The FA-2000 is a new solution for decapsulation of these special devices without the disadvantages of use of wet acids, including exposure of personnel to acid handling and disposal, corrosive residue on devices, and over-etching without end point detection.

Anatech recommends its FA-2000 reactive ion etcher for decapsulation and depassivation of packaged devices. A typical method of decapsulation is use of fuming nitric or sulfuric acid. Acid decapsulation systems can do an acceptable job for some devices, however, disadvantages include exposure of personnel to acid handling, high cost of ownership and acid disposal, corrosive residue on devices, and over-etching with no ease of end point detection.

New device technologies include metallization in integrated circuits and organic substrates in packaging. The FA-2000 is a new solution for decapsulation of these special devices.

A disadvantage of plasma decapsulation technology has been slow removal of epoxy and plastic molding materials. The cause of this problem is the build up of filler materials, such as silicon dioxide and quartz based fillers, which do not etch as quickly as organic components in the molding material. The result, if process is not interrupted with tedious manual brushing, is failure to decapsulate the device. An abandoned solution was the use of N2 gas to "blow" away the filler buildup. New molding materials in advanced packages and the use of hard epoxies made this approach ineffective. Process times with previous systems could take more than 48 hours !!!

Anatech's Fillerblast(TM) is the solution. Use of CO2 instead of N2 significantly enhances removal of fillers. A special manifold forms dry ice, which acts as a fine abrasive that is very effective in removing filler buildup. The plasma maintains a constant etch rate, which makes for a much more efficient removal of the molding material. The FA-2000 Fillerblast system also allows for an automatic change over to less aggressive CO2 blasts, or even extra gentle N2 blasts, to help preserve wire bonding. With the FA2000 etch rates for many compounds are more than 1 mil per hour.

After decapsulation of the device, the FA-2000 can also remove passivation or interdielectric layers. Anisotropic etching delivers aspect ratios needed to preserve functionality and operating condition of the device being treated. The system is capable of using any non corrosive gas and uses mass flow controllers tied into our versatile controller for easy, precise, gas mixing. Precise gas mixing is important to etch selectivity. FA-2000 systems can process wafers as large as 200 mm.


Contacts:

Sales:
Bill Smith Plasma Systems Sales Manager
USA
Send email  E-mail this person

General Information:
George Barr
USA
Phone: 704-489-1488

Company Information:
Name: BSET Plasmas
Address: 1011Detroit Ave., Ste. A
City: Concord
State: CA
ZIP: 94518
Country: USA
Phone: 925-354-7270
FAX: 925-754-7392
http://www.bestplasmas.com




Click here for copyright permissions!
Copyright 2009 Thomas Publishing Company


 

Post a comment about this story

Name:
E-mail:
(your e-mail address will not be posted)
Comment title:
Comment:
 

ThomasNet News Advertisers









Home  |  My ThomasNet News  |  Industry Market Trends  |  Submit Release  |  Advertise  |  Contact News  |  About Us
Brought to you by Thomasnet.com        Browse ThomasNet Directory

Copyright © 2009 Thomas Publishing Company
Terms of Use - Privacy Policy