![]() |
|
|
|
|
Latest New Product News from Bryant Electric
![]() Cord Sets offer portable ground fault protection.Bryant Electric Milford, CT 06460 2465Jun 08, 2007 Suited for industrial, commercial, and construction environments, 15 A in-line cord sets come in single- and triple-tap configurations and can be used indoors or outdoors. Portable ground fault products feature heavy-duty construction and NEMA-3R rating. LED indicator provides at-a-glance power and fault status, while recessed test and reset buttons help user avoid accidental actuation during handling and use. Products are offered with automatic reset or manual (safe-start) reset. ![]() Ground Fault Sensing Module protects outlets on generators.Bryant Electric Milford, CT 06460 2465Apr 27, 2007 Functioning interdependently with magnetic branch circuit breaker, GFCI module monitors electrical circuit by use of external differential current transformer. No direct load is present at module, and in case of ground fault, load is interrupted by way of circuit breaker utilizing shunt trip coil. Available with automatic or manual safe start reset feature, unit is rated from 1-15 A and is suited for circuit-carrying conductors from 1-3 poles. ![]() Metal Raceways accommodate 3 Cat, 5, 5e, or 6 cables.Bryant Electric Milford, CT 06460 2465Jan 30, 2007 Designed to satisfy electrical power or low voltage data/communications applications, Metal Surface Raceways consist of PlugTrak multi-outlet pre-wired system with 15 A receptacles. UL classified transition fittings allow transition from metal raceway to Wiremold® metal raceway, while open system architecture is possible through use of cover plates and bezels. ![]() Wall Plates feature durable Nylon design.Bryant Electric Milford, CT 06460 2465Oct 19, 2006 Combining rigid characteristics of thermoset with unbreakable characteristics of nylon, Wall Plates are intended for industrial, commercial, and residential applications. Units feature smooth gloss finish, slightly rounded corners, and slightly extended dimensions that cover oversized holes. Depth of 0.25 in. accommodates rework boxes. All single gang plates, along with decorator style plates up to 6-gang, come with pre-inserted captive screws. ![]() Straight-Blade Plug and Connector comes with cord clamp.Bryant Electric Milford, CT 06460 2465May 02, 2006 Plugs and connectors feature Triple-Gripper® cord clamp, which automatically centers and secures cord as assembly screws on face of device are tightened. Radius teeth design firmly holds cord without damaging conductors or use of external clamps or screws. Thermoplastic elastomer dust seal surrounds cord clamp opening, preventing ingress of moisture and contaminants. Designed with nylon face and housing, products feature double wall construction and accommodate 0.300-0.655 in. wires. ![]() Ground Fault Receptacles feature self-testing design.Bryant Electric Milford, CT 06460 2465Dec 09, 2005 CIRCUITPRO(TM) Devices continually test themselves every 60 sec to verify that they are fully operational, while still providing ground fault protection. Units quickly notify user if ground fault protection has been compromised or if ground fault condition exists. Status of ground fault is indicated through red and green LED on face of device. Available in commercial grade, hospital grade, and blank face models, receptacles include 10,000 A short circuit rating. ![]() Generator Power Connection Kit is protected from weather.Bryant Electric Milford, CT 06460 2465Sep 19, 2005 Generator Power Connection Kit features 2 in. deep, cast aluminum, weatherproof box that comes with powder-coated finish for protection against the elements. It includes receptacle securely mounted to cover and comes with all wiring devices and mounting hardware required for safe inlet for portable generator installation. Heavy-duty, industrial-grade base is integrated with cover. ![]() Pool Pump Receptacle Kit combines power and control.Bryant Electric Milford, CT 06460 2465Sep 01, 2005 Featuring 2-gang design in weatherproof aluminum box, Pump Receptacle Kit provides power and on/off switching for outdoor water pumps for pools, spas, and fountains. It is offered with 20 A/120–277 Vac single-pole switch and 20 A/125 V NEMA L5-20 locking receptacle or 20 A/120–277 Vac double-pole switch and 250 V NEMA L6–20 locking receptacle. Mounting hardware, gasket, closure plugs, wire connector, and instructions are included. ![]() Ground Fault Receptacle provides added safety for end users.Bryant Electric Milford, CT 06460 2465Jul 07, 2005 When test button is pushed, LED GFR® cycles through complete functional test and will return flashing red LED light if ground fault protection is compromised. It will also provide convenience power at face of receptacle to help prevent unsafe practices while device is out of service. If device is improperly wired, mis-wire protection blocks power at face or downstream loads. Unit meets UL943 surge testing, preventing inoperative power condition that locks out end user. ![]() GFCI Receptacles meet and exceed UL943 requirements.Bryant Electric Milford, CT 06460 2465May 20, 2003 Ground Fault Circuit Interrupting Duplex Receptacles include 15 and 20 A commercial and hospital grade devices featuring large 50 J, 250 V metal oxide varistor for surge immunity. Noise filtration circuitry prevents false tripping from EMI or RFI, and conformal coated circuit board enhances moisture and corrosion immunity. Receptacles include back and side wiring capability, tri-drive screws, and line-load reversal indication. Other Company News From Bryant Electric
Jan 21, 2006 Bryant Announces New Online Ordering Capability for Promotional Literature and Displays |
![]() |
||||||||||||||||
| Home | My ThomasNet News® | Industry Market Trends® | Submit Release | Advertise | Contact News | About Us |
![]() |
|
Brought to you by Thomasnet.com
Browse ThomasNet Directory |