![]() |
|
|
|
|
Latest New Product News from AR RF/Microwave Instrumentation
![]() Solid-State RF Amplifiers come in 200 W and 400 W models.AR RF/Microwave Instrumentation Souderton, PA 18964Dec 13, 2012 Covering 10 kHz to 400 MHz frequency range, Models 200A400 and 400A400 deliver power required for applications using MIL-STD, DO 160, and other automotive standards. Each amplifier utilizes linear devices in all high power stages to minimize distortion and optimize stability. Providing local and remote control of amplifier, Digital Control Panel displays operational presentation of Forward Power and Reflected Power plus control status and reports of internal amplifier status. Solid-State Amplifiers cover 0.8-4.2 GHz frequency range.AR RF/Microwave Instrumentation Souderton, PA 18964Aug 30, 2012 Offering 525 W and 700 W of RF power, respectively, Models 525S1G4 and 700S1G4 are 24U high and utilize state-of-the-art circuitry to minimize distortion. Each is equipped with Digital Control Panel, which enables both local and remote control of amplifier. Display provides operational presentation of Forward Power and Reflected Power plus control status and reports of internal amplifier status. Special features include gain control and RF output level protection. ![]() Electric Field Analyzer Kits provide detailed information.AR RF/Microwave Instrumentation Souderton, PA 18964Aug 24, 2012 Used to measure modulated electric fields as well as CW electric fields, FA7000 series Field Analyzers uses isotropic field sensor to sample composite field and transmit its amplitude digitally over optical fiber to processor unit. Sample rate is 1.5 MSPS, enabling accurate measurement of pulsed electric fields in micro-second range. Each kit comprises isotropic field sensor, glass fiber-optic cabling, and processor unit. Latter stores amplitude corrections for associated field sensor. ![]() Multi-Tone RF Test System minimizes testing time.AR RF/Microwave Instrumentation Souderton, PA 18964Mar 30, 2012 Reducing radiated immunity testing from days to hours, model MT06000 (80 MHz to 6 GHz) mimics real world threats with ability to expose EUT's to more than one frequency concurrently. Device can test up to 10 frequencies simultaneously and includes all necessary instruments to perform radiated immunity testing per IEC 61000-4-3, except requisite amplifiers, antennas, and directional couplers. Amplifiers are selected and sized based on end-user's required field levels and testing needs. ![]() RF Power Amplifier covers 10 kHz to 225 MHz frequency range.AR RF/Microwave Instrumentation Souderton, PA 18964Nov 30, 2011 Featuring air-cooled, solid-state design, 600 W Model 600A225 is equipped with digital control panel that provides both local and remote control using IEEE, RS-232, USB, and Ethernet interfaces. Panel features 3.75 in. diagonal graphic display, menu-assigned softkeys, and single rotary knob as well as 4 dedicated switches for extensive control and status reporting capabilities. Typical applications include RF susceptibility testing, antenna testing, watt meter calibration, and plasma generation. High-Output Power Modules cover 4-18 GHz bandwidth.AR RF/Microwave Instrumentation Souderton, PA 18964Aug 30, 2011 Hybrid Power Modules (HPMs) deliver linear output powers approaching 5 W across instantaneous bandwidth of 4-18 GHz. Exhibiting optimized gain flatness, products can withstand infinite output mismatch and are available in various power and gain configurations. HPMs can be customized to meet individual specifications concerning bandwidth/power requirements. Also, products can be supplied as military and commercial solutions as well as in true hermetic connectorized or open pallet designs. Radiated Immunity Test System covers MIL-STD 461 requirements.AR RF/Microwave Instrumentation Souderton, PA 18964May 20, 2011 Used to conduct radiated susceptibility tests, AS18027 produces fields up to 50 V/m at 1 m from 1-18 GHz. Automated system comprises dual-band, solid-state amplifiers; signal generation and control equipment; frequency matched and dedicated antennas; and SW1007 EMC test software. Equipment is housed in EMI-shielded rack, designed to be kept inside chamber, and capabilities for safety interlock allow single switch to be monitored and all RF generation inside chamber to be disabled. ![]() 3-Channel Power Meter covers range of 10 kHz to 40 GHz.AR RF/Microwave Instrumentation Souderton, PA 18964Feb 02, 2010 Offering power measurement range from -70 to +44 dBm, Model PM2003 delivers 200 readings/sec with 1 channel and 100 readings/sec when 2 channels are used. Two channels can be simultaneously displayed and recorded, while third channel can be switched in to be displayed or recorded. Meter offers wide dynamic range, which can extend to 90 dB when diode power heads are used, and to 50 dB with thermocouple heads. RF Amplifiers have impedance-matching capabilities.AR RF/Microwave Instrumentation Souderton, PA 18964Jan 10, 2008 Featuring internal impedance transformer with selectable output impedance values of 12.5, 25, 50, 100, 200, and 400 W, A3 amplifiers are suited for R&D applications and general purpose lab use. Models 800A3 (800 W), 1500A3 (1,500 W), and 5000A3 (5,000 W) cover 10 kHz to 3 MHz frequency range. External impedance transformer is also available for applications requiring extended range from 8-2,000 W. Magnetic Immunity Amplifier lets user test susceptibility.AR RF/Microwave Instrumentation Souderton, PA 18964Jan 09, 2008 Model 350AH1 is 350 W, 10 Hz to 1 MHz magnetic immunity amplifier that is used for susceptibility testing for magnetic and audio frequency tests in MIL-STD-461D/E, D0160D/E, and variety of automotive test standards. Unit can also be used as ac voltage source for watt-meter calibration and as driver for higher-power amplifiers. It is powered by switching supply with auto-ranging ac input circuitry that automatically accepts voltages from 90-260 Vac in 47-63 Hz frequency range. Click below for more Product News from AR RF/Microwave Instrumentation Next News Stories Other Company News From AR RF/Microwave Instrumentation
Oct 16, 2012 New AR Amplifier Instantaneously Covers the 1 - 6 GHz Frequency BandMar 23, 2011 Redesigned "S" Series Amplifiers from AR Now Offer Coverage 4 - 18 GhzJan 22, 2011 AR Continues to Pack More Power into Smaller, Compact "S" Series AmplifiersSep 15, 2007 AR Laser Probes Now Come Standard with an A2LA Accredited, NIST Traceable Calibration at No Extra ChargeFeb 08, 2007 AR Adds Higher Power Amplifiers for Testing in the 4.0 - 10.6 GHz Frequency Range |
![]() |
||||||||||||||||
| Home | My ThomasNet News® | Industry Market Trends® | Submit Release | Advertise | Contact News | About Us |
![]() |
|
Brought to you by Thomasnet.com
Browse ThomasNet Directory |